Output ports
Number of switched channels4
Peak load15mA
Input ports
Number of inputs2
Other
Supply voltage11.5...27.5 V DC
Dimentions2U, 36x97x58 mm


MODULE FOR DEVICES WITH 0-10V INPUT OR OUTPUT

This module allows connecting devices with 0-10V inputs and outputs to the Smart Home system

Features

  • 4x0-10V outputs
  • 2x0-10V inputs

CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. To avoid the risk of fire, electric shock, damage to the system and/or personal injury, the system installation and assembly must be performed in accordance with the instructions listed below:

  • all connectivity work must be carried out with the power turned OFF;
  • use appropriate tools and personal protection against electric shock;
  • do not use damaged cables, wires and connectors;
  • avoid folding the cables and wires;
  • do not apply excessive force to the wires by kinking or pressing them too hard: the inner conductors of the cables and wires may get stripped or damaged;
  • do not use the power socket with poor contacts to connect;
  • do not exceed the load limit parameters specified in the manual;
  • the supply conductors wire section is subject to the specifications for current density limit, insulation type and wire material. Light section can result in cable overheating and fire.

When the power is on, NEVER:

  • connect/disconnect the connectors;
  • open modules and sensors.

Overview

 

Module dimensions

 

Connection of 6 0-10V devices

 

Module parameters

Parameter name Value
Input channels qty 2
Input/output channels qty
0-10 input port quantity
Buttons
LED Buttons
Number of sensor inputs
Number of dry contact inputs
RS485 ports qty
RS232 ports qty
UART ports qty
M-BUS port quantity
Pulse inputs quantity
DALI ports qty
DALI-line voltage supply
Peak current of DALI-line power supply
Peak current in DALI-line
Maximum DALI devices quantity
Dimming channels qty
Output channels qty 4
0-10 output port quantity
Analog output channels qty
Output
Digital line maximum length
Discrete input channels qty
Digital input channels qty
Speakers
Max power output audio channel
Camera
IR lighting
Card reader
Connection type
Protocols
Backlight voltage
Load type
Dimmer load type
Supported sensors
Input voltage
Current type
Adjustment type
Max load
Min load
Max load per channel 15mA
Max load per group
Max load per device
Control parameters
Angle of vision IR °
Angle of motion °
Temperature measuring range °C
Humidity measuring range
Dimmer type
Dimming type
Voltage that may be applied to the input channels
Max output switching voltage
Max output switching current
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 50 mA
Max current(13V)
Max detection distance
Max IR distance
Max BT distance
Max current
Relay
Data transfer speed
Permissible section of power supply cable to connect in socket:
Sensors VCC output
Sensors max VCC current
R1-R2 inputs max current
Push-button/reed switches line recommended length 30m
Temperature sensor line max length
Sensor cable length
Sensors line max length
Bus type CAN (4-wire)
Compatible with
Output voltage
Output current
Equipment installation type DIN rail (EN 60715)
Mounting
Max cabel lenght
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 2U, 36x97x58 mm
Weight 130g
* -
** -
*** -
1 -
2 -
3 -


Indication of module operation

Bootloader

Indicator Status Description
 
  Device in bootloader
 
   Downloading firmware
   Flashing firmware

Firmware

Indicator Status Description
 
     Network configuration
     Identification
  Operational mode
  Operational mode
 

Error
  Lost connection to server
   Overheat
    Overload
     No AC power
      RTC error
 

Activity
  CAN activity
  OW activity
  RS-485 activity
  Ethernet activity


Module installation and connection procedure

  1. Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base.
  2. Connect the input/output connectors.
  3. Connect the CAN connector.
  4. Configure the module using LT setup.
  5. Check all equipment for proper operation.

Module shut-off and deinstallation procedure

  1. Disconnect the CAN connector.
  2. Disconnect the input/output connectors.
  3. Remove the module from the DIN rail, releasing the latch at the bottom of the module base.

HW settings

Name Type, range SUBID Default Description
def integer 0-250 1-4 100 The default brightness level in case of a power reset (1..250). Example: def=250
min integer 0-100 1-4 0 Minimum dimming level, example: min=10
max integer 0-100 1-4 100 Maximum dimming level, example max=95
start integer 0-100 1-4 0 The Start function is used for lamps that lack the minimal voltage to get turned on. If the set value is lower than the start value, the lamp is turned on at the start value and them the light is dimmed down to the set level. Example: start=60
force integer 0-100 1-4 10 Time duration of the starting value (measured in milliseconds). Example: force=20
runtime integer 0-60000 1-4 1000 Runtime is the speed of changing the brightness from ‘min’ to ‘max’ (measured in milliseconds). Example: runtime=1000
dm char[4] 98 'vvvv' Each char is responsible for the type of a particular channel
  • 'g' – use like halogen dimmer-lamp
  • 's' – Soft Switch, lamp, when on/off power is supplied/deenergised smoothly (500msec)
  • 'k' – Switch, lamp, when on/off power is supplied/deenergised immediately
  • 'l' – LED Function, dimmable LED lamps
  • 'v' – linear Function of dimming
  • '-' – Channel disabled
  • '+' – Regular channel

Example: dm='skl-'

1<item addr="416:1" auto-period="600" cfgid="144" name="Dimmer 1" type="dimmer-lamp"/>
2<item addr="416:2" auto-period="600" cfgid="144" name="Dimmer 2" type="dimmer-lamp"/>
3<item addr="416:3" auto-period="600" cfgid="144" name="Dimmer 3" type="dimmer-lamp"/>
4<item addr="416:4" auto-period="600" cfgid="144" name="Dimmer 4" type="dimmer-lamp"/>
5<item addr="416:31" cfgid="144" name="Voltage" system="yes" type="voltage-sensor"/>
6<item addr="416:32" cfgid="144" name="Voltage" system="yes" type="voltage-sensor"/>
7<item addr="416:97" cfgid="144" name="Temperature" system="yes" type="temperature-sensor"/>
8<item addr="416:98" cfgid="144" logic-ver="19" name="Temperature"  system="yes" type="temperature-sensor"/>