WW-HTL

Revision as of 12:41, 10 January 2022 by Rusanov (talk | contribs) (Marked this version for translation)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Other languages:
English • ‎русский
WW-HTL.C
WW-HTLС.png
Sensors
Control parametersTemperature, humidity, lighting
Temperature measuring range-10 … +50°C
Humidity measuring range0 … 100%
Other
Supply voltage11.5...27.5 V DC
Dimentions51x51x37 mm


WALL 3 IN 1 SENSOR

Contains temperature, lighting, and humidity sensors.

Module parameters

CAN connector pinout
 


Parameter name Value
Input channels qty
Input/output channels qty
0-10 input port quantity
Buttons
LED Buttons
Number of sensor inputs
Number of dry contact inputs
RS485 ports qty
RS232 ports qty
UART ports qty
M-BUS port quantity
Pulse inputs quantity
DALI ports qty
DALI-line voltage supply
Peak current of DALI-line power supply
Peak current in DALI-line
Maximum DALI devices quantity
Dimming channels qty
Output channels qty
0-10 output port quantity
Analog output channels qty
Output
Digital line maximum length
Discrete input channels qty
Digital input channels qty
Speakers
Max power output audio channel
Camera
IR lighting
Card reader
Connection type
Protocols
Backlight voltage
Load type
Dimmer load type
Supported sensors
Input voltage
Current type
Adjustment type
Max load
Min load
Max load per channel
Max load per group
Max load per device
Control parameters Temperature, humidity, lighting
Angle of vision IR °
Angle of motion °
Temperature measuring range -10 … +50°C
Humidity measuring range 0 … 100%
Dimmer type
Dimming type
Voltage that may be applied to the input channels
Max output switching voltage
Max output switching current
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 25 mA
Max current(13V)
Max detection distance
Max IR distance
Max BT distance
Max current
Relay
Data transfer speed
Permissible section of power supply cable to connect in socket:
Sensors VCC output
Sensors max VCC current
R1-R2 inputs max current
Push-button/reed switches line recommended length
Temperature sensor line max length
Sensor cable length
Sensors line max length
Bus type CAN (4-wire)
Compatible with
Output voltage
Output current
Equipment installation type Wall, celling
Mounting
Max cabel lenght
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 40x40x12 mm
Weight 50g
* -
** -
*** -
1 -
2 -
3 -


HW settings

Name Type, range SUBID Default Description
offset float (+/- 0…39) SubID of sensor 0 sensor values offset (for temperature sensors) Example:
1hw="offset='-3'"
scale float (0…8) SubID of sensor 1 multiplier determines the slope of values (except temperature sensors) Example:
1hw="scale='1.1'"
1<item addr="323:31" cfgid="83" name="Humidity" type="humidity-sensor" hw="scale='7.1'" uniq_id="4626"/>
2<item addr="323:32" cfgid="83" name="Temperature" hw="offset='-21'" type="temperature-sensor" uniq_id="4627"/>
3<item addr="323:33" cfgid="83" name="Illumination" type="illumination-sensor" hw="scale='6.2'" uniq_id="4628"/>
4<item addr="323:34" cfgid="94" name="Illumination" type="illumination-sensor"/> 
5<item addr="323:98" cfgid="83" name="Temperature" system="yes" type="temperature-sensor" uniq_id="4629"/>