Name type and variety description default value
temperature-sensors list list of valve temperature sensors (for automation) -
automation string name of current automation mode -
sub-type enum warm-floor -
temperature-lag number hysteresis range on either side from set-point temperature Set in automation tag. The decimal symbol is dot. 0.5
undefined-behavior enum
on/off/last
valve position in case of sensors readings absence last
sensor-cr list temperature-sensor measuring the maximum and minimum critical temperature -
sensor-cr-hi number upper temperature limit, to disable warm floor in case of overheating -
sensor-cr-lo number lower temperature limit, to activate the warm floor in case of overcooling. -
t-min number lower temperature limit to set 0
t-max number upper temperature limit to set 32