!Name!!Type, range!!SUBID!!Default!!Description
 
!Name!!Type, range!!SUBID!!Default!!Description
 
|-
 
|-
|in||char[16]||98||'BBBBBB'||Each char is responsible for the type of a particular channel
+
|slave||char[10]||98||-||Sn of slave BT-CAN module in hex format for P2P connection. Setting for master BT-CAN/DE-MG.Plus module only
*'B'-Button, button of bell a type;
+
Example:
*'C'-Inverted button, inverse button of a bell type (for normally-closed);
+
<syntaxhighlight lang="xml" line>hw="slave=0xe8245161"</syntaxhighlight>
*'D'-Backlit button, illuminated button;
  −
*'E'-Inverted backlit button, inverse illuminated button;
  −
*'S'-Switch, fixed switch;
  −
*'K'-Contact, reed contact;
  −
*'H'-Inverted contact, inverse reed contact;
  −
*'G'-GND, is used as earthing;
  −
*'-'-none, nothing is connected.
  −
And you can also connect one temperature sensor:
  −
<syntaxhighlight lang="xml" line>hw="in='T-----'"</syntaxhighlight>
  −
<syntaxhighlight lang="xml" line>Example: in='DEHSSG'</syntaxhighlight>
   
|-
 
|-
|offset||float(+/- 0…39)||SubID 30 temperature sensor||'0'||sensor values offset;
+
|pin||float(+/- 0…39)||98||-||Pin for P2P connection, must be same for master and slave
For example, offset is -3.8 :
+
Example:
<syntaxhighlight lang="xml" line>hw="offset='-3.8'"</syntaxhighlight>
+
<syntaxhighlight lang="xml" line>hw="pin=1111"</syntaxhighlight>
 
|}
 
|}
  