| Line 1: |
Line 1: |
| | <languages/> | | <languages/> |
| | <translate> | | <translate> |
| | + | <!--T:1--> |
| | {{Infobox module | | {{Infobox module |
| | | name = DW-HC08.A | | | name = DW-HC08.A |
| Line 15: |
Line 16: |
| | }} | | }} |
| | | | |
| − | ==8-CHANNEL HEATING CONTROLLER== | + | ==8-CHANNEL HEATING CONTROLLER== <!--T:2--> |
| | | | |
| | + | <!--T:3--> |
| | The device is designed for controlling heating devices (radiators, floor heating, fan coil units, etc.). | | The device is designed for controlling heating devices (radiators, floor heating, fan coil units, etc.). |
| | The device is equipped with 8 inputchannels for connection of temperature sensors (FW-FT or FW-TS). | | The device is equipped with 8 inputchannels for connection of temperature sensors (FW-FT or FW-TS). |
| | | | |
| − | ==Features== | + | ==Features== <!--T:4--> |
| | *8 outputs for NO/NC valves or contactors | | *8 outputs for NO/NC valves or contactors |
| | *8 inputs for digital temperature sensors (FW-FT or FW-TS) | | *8 inputs for digital temperature sensors (FW-FT or FW-TS) |
| Line 28: |
Line 30: |
| | *Built-in real time clock | | *Built-in real time clock |
| | | | |
| | + | <!--T:5--> |
| | <div class="caution"> | | <div class="caution"> |
| | CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. | | CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. |
| Line 44: |
Line 47: |
| | </div> | | </div> |
| | | | |
| − | ==Overview== | + | ==Overview== <!--T:6--> |
| | | | |
| | + | <!--T:7--> |
| | [[File:HC08A VIEW.png|500px]] | | [[File:HC08A VIEW.png|500px]] |
| | | | |
| − | ==Connection of 8 valves== | + | ==Connection of 8 valves== <!--T:8--> |
| | | | |
| | + | <!--T:9--> |
| | [[File:HC08A OUT.png|300px]] | | [[File:HC08A OUT.png|300px]] |
| | | | |
| − | ==Connection of 8 temperature sensors== | + | ==Connection of 8 temperature sensors== <!--T:10--> |
| | | | |
| | + | <!--T:11--> |
| | [[File:HC08A IN.png|300px]] | | [[File:HC08A IN.png|300px]] |
| | | | |
| − | ==Module dimensions== | + | ==Module dimensions== <!--T:12--> |
| | | | |
| | + | <!--T:13--> |
| | [[File:HC08A DIM.png|500px]] | | [[File:HC08A DIM.png|500px]] |
| | | | |
| − | ==Internal layout== | + | ==Internal layout== <!--T:14--> |
| | | | |
| | + | <!--T:15--> |
| | [[File:HC08A IL.png|500px]] | | [[File:HC08A IL.png|500px]] |
| | | | |
| − | ==Module parameters== | + | ==Module parameters== <!--T:16--> |
| | | | |
| | + | <!--T:17--> |
| | {{Mp | | {{Mp |
| | | outqty = 8 | | | outqty = 8 |
| Line 84: |
Line 93: |
| | }} | | }} |
| | | | |
| − | ==Connection of high load device== | + | ==Connection of high load device== <!--T:18--> |
| | | | |
| | + | <!--T:19--> |
| | {| class="wikitable" style="max-width:800px" ; | | {| class="wikitable" style="max-width:800px" ; |
| | |- | | |- |
| Line 94: |
Line 104: |
| | |} | | |} |
| | | | |
| − | ==Indication of module operation== | + | ==Indication of module operation== <!--T:20--> |
| | {{indicationold}} | | {{indicationold}} |
| | ==Module installation and connection procedure== | | ==Module installation and connection procedure== |
| | | | |
| | + | <!--T:21--> |
| | *Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base. | | *Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base. |
| | *Connect the CAN connector. | | *Connect the CAN connector. |
| Line 105: |
Line 116: |
| | *Check all equipment for proper operation. | | *Check all equipment for proper operation. |
| | | | |
| − | ==Module shut-off and deinstallation procedure== | + | ==Module shut-off and deinstallation procedure== <!--T:22--> |
| | | | |
| | + | <!--T:23--> |
| | *Disconnect the power from the load. | | *Disconnect the power from the load. |
| | *Disconnect the X1-X3 connectors. | | *Disconnect the X1-X3 connectors. |
| Line 112: |
Line 124: |
| | *Remove the module from the DIN rail, releasing the latch at the bottom of the module base. | | *Remove the module from the DIN rail, releasing the latch at the bottom of the module base. |
| | | | |
| − | ==HW settings== | + | ==HW settings== <!--T:24--> |
| | {| class="wikitable" | | {| class="wikitable" |
| | |- | | |- |
| Line 119: |
Line 131: |
| | |runtime||integer 0-100||1-8||15||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15 | | |runtime||integer 0-100||1-8||15||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15 |
| | | | |
| | + | <!--T:25--> |
| | |- | | |- |
| | |hold||integer 0-10000||1-8||500||hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500 | | |hold||integer 0-10000||1-8||500||hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500 |
| Line 154: |
Line 167: |
| | |} | | |} |
| | | | |
| | + | <!--T:26--> |
| | <syntaxhighlight lang="xml" line=""> | | <syntaxhighlight lang="xml" line=""> |
| | <item addr="348:1" cfgid="43" name="Jalousie" sub-type="120" type="jalousie" uniq_id="4097" hw="runtime=45"/> | | <item addr="348:1" cfgid="43" name="Jalousie" sub-type="120" type="jalousie" uniq_id="4097" hw="runtime=45"/> |