Line 382: Line 382:  
|Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.
 
|Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.
 
|mf10exa11|Fig. 12|Two adjacent contact points (for example, 3, 4) should be used to connect the curtain/jalousie/rolladens actuator with low-voltage control. The example of connection is shown in '''Fig.12'''.|.png|150}}
 
|mf10exa11|Fig. 12|Two adjacent contact points (for example, 3, 4) should be used to connect the curtain/jalousie/rolladens actuator with low-voltage control. The example of connection is shown in '''Fig.12'''.|.png|150}}
 +
 +
===Connection of sensing elements/switches/buttons===
 +
 +
====Connection of motion sensors====
 +
 +
The motion sensors should be connected to any free input in1-in24; in these conditions their power is connected to the contact points of +12V and GND of the relevant group. The example of connection is shown in '''Fig.11'''.
 +
 +
[[File:msConn.png|300px|ms]]
 +
<br>
 +
'''Fig. 11'''
 +
 +
 +
====Connection of FW-WL.A leakage sensors====
 +
 +
FW-WL.A leakage sensors are connected to any free input in1 – in24, in these conditions the power should be connected to +12V and GND points of the relevant group. The example of connection is shown in '''fig. 12'''.
 +
{| style="width"700px"
 +
|- style="tezt-align:center;"
 +
|[[File:Leak1.png|300px|center]]<br>'''Fig12'''||[[File:Leak2.png|300px|center]]<br>'''Fig13'''
 +
|}
 +
 +
Configuration and connection of the FW-WL.A sensor
 +
1. Terminals:
 +
:'''+12V''' — sensor power is connected to the contact point of METAFORSA “+12V”;
 +
:'''OW''' — sensor pickup signal;
 +
:'''GND''' — common, connected to GND contact of METAFORSA.
 +
2. Sensor preset switch (optionally):
 +
:1 — sensor sensitivity (ON – high, OFF – low);
 +
:2 — indicator colour setting (ON – blue, OFF – green).
 +
3. LED status indicator.
 +
 +
====Connection of buttons/switches/magnetic reed switches====
 +
 +
Buttons and reed switches are connected to any free input in1-in16, while their second contact point is connected to GND point of the relevant METAFORSA module group, + 12V power outputs – not in use. The example of connection is shown in '''Fig. 14-16'''.
 +
{| style="width"700px"
 +
|- style="tezt-align:center;"
 +
|[[File:Buttons.png|300px|center]]<br>'''Fig14''' connection of buttons/switching units || [[File:Reed-sv.png|300px|center]]<br>'''Fig15''' connection of the magnetic reed switches (window/door position sensors)
 +
|}
 +
 +
 +
====Connection of digital sensors====
 +
 +
The OW adapter ('''Fig. 16a''') is supplied along with METAFORSA module with the possibility to connect up to 8 digital sensors to it. In these conditions, several devices can be connected to one channel ('''Fig. 16b'''). The connected sensors are detected automatically and do not require any original setting.
 +
 +
{| style="width"700px"
 +
|- style="tezt-align:center;"
 +
|[[File:Ow1Conn.png|300px|center]]<br>'''Fig16 a'''||[[File:Ow2Conn.png|300px|center]]<br>'''Fig16 b'''
 +
|}
 +
'''Configuration and connection of the OW adapter'''
 +
<div style="width:700px; background-rgb:#dededf">'''Caution: Ensure the connection is correct. The incorrect connection may cause sensor and/or module malfunction. '''</div>