Line 1: |
Line 1: |
| <languages/> | | <languages/> |
| <translate> | | <translate> |
| + | <!--T:1--> |
| {{RevisionChanger | hasA = 1 | hasC = 1}} | | {{RevisionChanger | hasA = 1 | hasC = 1}} |
| {{Infobox module | | {{Infobox module |
Line 11: |
Line 12: |
| }} | | }} |
| | | |
− | ==RS485 INTERFACE ADAPTER== | + | ==RS485 INTERFACE ADAPTER== <!--T:2--> |
| | | |
| + | <!--T:3--> |
| This module is designed for interface adjustment between the devices which have the RS485 interface and the Smart Home system. This module has an internal 120Ω terminator resistor. | | This module is designed for interface adjustment between the devices which have the RS485 interface and the Smart Home system. This module has an internal 120Ω terminator resistor. |
| | | |
| | | |
− | ==Features== | + | ==Features== <!--T:4--> |
| | | |
| + | <!--T:5--> |
| *Features | | *Features |
| *Supported protocols: | | *Supported protocols: |
Line 25: |
Line 28: |
| *1200 – 115200 baud rate | | *1200 – 115200 baud rate |
| | | |
| + | <!--T:6--> |
| <div class="caution"> | | <div class="caution"> |
| CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. | | CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. |
Line 41: |
Line 45: |
| </div> | | </div> |
| | | |
− | ==Overview== | + | ==Overview== <!--T:7--> |
| | | |
| + | <!--T:8--> |
| [[File:RS485C VIEW.png|300px]] | | [[File:RS485C VIEW.png|300px]] |
| | | |
− | ==Module dimensions== | + | ==Module dimensions== <!--T:9--> |
| | | |
| + | <!--T:10--> |
| [[File:RS485C DIM.png|500px]] | | [[File:RS485C DIM.png|500px]] |
| | | |
− | ==Example of connection== | + | ==Example of connection== <!--T:11--> |
| | | |
| + | <!--T:12--> |
| [[File:RS485C EXA.png|300px]] | | [[File:RS485C EXA.png|300px]] |
| | | |
− | ==Module parameters== | + | ==Module parameters== <!--T:13--> |
| | | |
| + | <!--T:14--> |
| {{ Mp | | {{ Mp |
| | rs485qty = 1 | | | rs485qty = 1 |
Line 69: |
Line 77: |
| }} | | }} |
| | | |
− | ==Indication of module operation== | + | ==Indication of module operation== <!--T:15--> |
| ===Bootloader=== | | ===Bootloader=== |
| {{indication| textBBB= Waiting for bootloader command}} | | {{indication| textBBB= Waiting for bootloader command}} |
Line 86: |
Line 94: |
| }} | | }} |
| | | |
− | ==Module installation and connection procedure== | + | ==Module installation and connection procedure== <!--T:16--> |
| #Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base. | | #Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base. |
| #Connect the X1 connector. | | #Connect the X1 connector. |
Line 93: |
Line 101: |
| #Check all equipment for proper operation. | | #Check all equipment for proper operation. |
| | | |
− | ==Module shut-off and deinstallation procedure== | + | ==Module shut-off and deinstallation procedure== <!--T:17--> |
| #Disconnect the CAN connector. | | #Disconnect the CAN connector. |
| #Disconnect the X1 connector. | | #Disconnect the X1 connector. |
| #Remove the module from the DIN rail, releasing the latch at the bottom of the module base. | | #Remove the module from the DIN rail, releasing the latch at the bottom of the module base. |
| | | |
− | ==HW settings== | + | ==HW settings== <!--T:18--> |
| {|class="wikitable" | | {|class="wikitable" |
| |- | | |- |