==HW settings==
{|class="wikitable"
|-
!Name!!Type, range!!SUBID!!Default!!Description
|-
|in||char[16]||98||'BBBBBB'||Each char is responsible for the type of a particular channel
*'B'-Button, button of bell a type;
*'C'-Inverted button, inverse button of a bell type (for normally-closed);
*'D'-Backlit button, illuminated button;
*'E'-Inverted backlit button, inverse illuminated button;
*'S'-Switch, fixed switch;
*'K'-Contact, reed contact;
*'H'-Inverted contact, inverse reed contact;
*'G'-GND, is used as earthing;
*'-'-none, nothing is connected.
And you can also connect one temperature sensor:
<syntaxhighlight lang="xml" line>hw="in='T-----'"</syntaxhighlight>
<syntaxhighlight lang="xml" line>Example: in='DEHSSG'</syntaxhighlight>
|-
|offset||float(+/- 0…39)||SubID 30 temperature sensor||'0'||sensor values offset;
For example, offset is -3.8 :
<syntaxhighlight lang="xml" line>hw="offset='-3.8'"</syntaxhighlight>
|}