{{RevisionChanger | hasA=1|hasC=1}}
{{Infobox module
| name = BW-IO.C
| image = BW-IOC.png
| outCount = 3
| inCount = 3
| voltage = 11.5...27.5 V DC
| dim = 45x42x14 mm
}}
==6-CHANNEL I/O MODULE==
The module is designed for connection of other digital devices which
do not have standard interfaces
<div class="caution">
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
To avoid the risk of fire, electric shock, damage to the system and/or personal injury, the system installation and assembly must be performed in accordance with the instructions listed below:
*all connectivity work must be carried out with the power turned OFF;
*use appropriate tools and personal protection against electric shock;
*do not use damaged cables, wires and connectors;
*avoid folding the cables and wires;
*do not apply excessive force to the wires by kinking or pressing them too hard: the inner conductors of the cables and wires may get stripped or damaged;
*do not use the power socket with poor contacts to connect;
*do not exceed the load limit parameters specified in the manual;
*the supply conductors wire section is subject to the specifications for current density limit, insulation type and wire material. Light section can result in cable overheating and fire.
When the power is on, NEVER:
*connect/disconnect the connectors;
*open modules and sensors.
</div>
==Example of connection==
[[File:BWIOC EXA.png|500px]]
==Module parameters==
{{ Mp
| outqty = 3
| inqty = 3
| involtage2 = 0…15 V DC
| maxoutswv = 60V AC/DC
| maxoutswcur = 50mA
| power = 11.5 … 27.5 V DC from CAN
| maxcur24v = 25 mA
| bustype = CAN (4-wire)
| instalation = Free
| case = ABS
| protection = IP40
| temprange = -10 … +50 °C
| size = 45x42x14 mm
| weight = 15 g
}}
==Module installation and connection procedure==
#Connect the outputs.
#Connect the inputs.
#Connect the CAN connector.
#Configure the module using LT setup.
#Check all equipment for proper operation.
==Module shut-off and deinstallation procedure==
#Disconnect the CAN connector.
#Disconnect the inputs.
#Disconnect the outputs.
==HW settings==
{|class="wikitable"
|-
!Name!!Type, range!!SUBID!!Default!!Description
|-
|io||char[6]||98||'HHHLLL'||Each char is responsible for the type of a particular channel
*1-3 channels
**'H' – Contact
**'K' – Inverted contact
**'L' – Backlit button
**'M' – Inverted backlit button
*4-6 channels
**'L'-Lamp
**'M'-Lamp Inverse;
**'J'-Heating NO, valve-heating, normally open;
**'H'-Heating NC, valve-heating, normally closed;
**'B'-Blinds, jalousie/curtains(2 pole);
**'C'-Blinds Inverse, jalousie/curtains, invert open-close(2 pole);
**'G'-Gate (2 pole), 2 pole gate;
**'D'-Gate (2 pole) Inverse, 2 pole gate, invert open-close;
**'X'-Gate (1 pole /short press), 1 pole gate;
**'Z'-Gate (1 pole) Inverse, 1 pole gate, invert open-close;
**'V'-Valve (2 pole), 2 pole valve,;
**'W'-Valve (2 pole) Inverse, 2 pole valve, invert open-close;
**'R'-Valve (1 pole), 1 pole valve;
**'S'-Valve (1 pole) Inverse, 1 pole valve, invert open-close;
**'K'-Lock (short press);
**'N'-Lock (short press) Inverse;
**'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control;
**'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control;
**'Q'-FanCoil. Group3 (Lamp Toggle). For fancoil speed control;
**'U'-FanCoil. Group4 (Lamp Toggle). For fancoil speed control;
**'I'-FanCoil. Group5 (Lamp Toggle). For fancoil speed control;
**'-'-none, nothing is connected.
Example:
<syntaxhighlight lang="xml" line>
hw="io='KKKLLL'"
</syntaxhighlight>
|}