1,355 bytes added
, 12:40, 10 January 2022
<languages/>
{{Infobox module
| name = FW-FT
| image = FW-FT.png
| cp = Temperature
| temperature= -20 … +60°C
| voltage = 5 V DC
| dim = 8x8x50 mm
}}
==UNDERFLOOR HEATING TEMPERATURE SENSOR==
This is an underfloor heating temperature sensor for DW-HCxx, it can also be used to measure the outdoor temperature.
==Pin assignments==
[[File:FWFT PIN.jpg|300px]]
==Example of connection==
[[File:FWFT EXA.jpg|400px]]
==Example of connection==
[[File:FWFT EXA2.jpg|600px]]
==Module parameters==
{{ Mp
| ctrlparams = Temperature
| tempmrange = -20 … +60
| power = 5 V DC
| maxcur = 5 mA
| bustype = One Wire
| Compatible = DW-HCxx<br>BW-LC/BCxx/SW<br>DW-HTO7(OW)<br>MF(OW)
| instalation = Built into the floor/outdoor
| case = ABS
| smaxlen = 30 m*
| tscablen = 3m
| protection = IP65
| temprange = -20 … +60 °C
| size = 8x8x50 mm
| weight = 15g
| star1 = +5V and COM should be connected in one twisted pair, and DATA at free one
}}
==HW settings==
{|class="wikitable"
|-
!Name!!Type, range!!SUBID!!Default!!Description
|-
|offset||float (+/- 0…39)||SubID of sensor||0||sensor values offset (for temperature sensors) Example:
<syntaxhighlight lang="xml" line>
hw="offset='-3'"
</syntaxhighlight>
|}