Changes

1,025 bytes added ,  15:08, 24 January 2022
Importing a new version from external source
{|class="wikitable"
|-
!Name!!type and variety!!description!!default value
|-
|path*||string||Path to script||-
|-
|script-id||string||script id from the description for interface||-
|-
|t-min||number||temperature low value||16
|-
|t-delta||number||temperature range||16
|-
|modes||bit mask||Mask of operation modes (fan, cool, dry, heat, auto)||0x1F
|-
|fans||bit mask||Mask of airflow mode (auto, 1, 2, 3, 4, 5, silent mode)||0x1F
|-
|vane-ver||bit mask||Mask of vertical fins mode (auto, top, top-center, center, center-bottom, bottom, swing)||0x7E
|-
|vane-hor||bit mask||Mask of horizontal fins mode (left, left-center, center, center-right, right, sides (low angle), sides (high angle), from sides to center)||0
|-
|temperature-sensors||list||list of valve temperature sensors||-
|-
|t-outside||addr||addr of outside temperature sensors||-
|-
|t-outside-treshold||value||critically low temperature treshold||-
|-
|t-outside-hyst||value||critically low temperature hysteresis||-
|}
<nowiki>*</nowiki> – required fields
3,388

edits