| EW-WL.B | |||||||
|---|---|---|---|---|---|---|---|
|  | |||||||
| 
 | |||||||
BUILT-IN FLOOR LEAKAGE SENSOR
Water leakage sensor with an alarm light, mountable in the floor surface. Used together with DW-WL02 or BW-LSA modules.
Pin assignment
Example of connection
Module parameters
| Parameter name | Value | 
|---|---|
| Power supply | 9-12 V DC | 
| Max current(24V) | 20 mA | 
| Compatible with | MF-10 DW-WL02/HTxx BW-LSA | 
| Equipment installation type | Built into the floor | 
| Case material | stainless steel | 
| Protection | IP65 | 
| Temperature range | -10 … +50 °C | 
| Size | 18x18x20 mm | 
| Weight | 20g | 
HW settings
| Name | Type, range | SUBID | Default | Description | 
|---|---|---|---|---|
| c0 | int[4] | sensors subId | 0;0;255;15 | Normal state color in format 'red;green;blue;blink' red, green, blue – 0..255; blink: 
 Example: 1c0='150;150;255;0'
 | 
| c1 | int[4] | sensors subId | 0;0;255;15 | On-start color in format 'red;green;blue;blink' red, green, blue – 0..255; blink: 
 Example: 1c1='150;150;255;0'
 | 
| c2 | int[4] | sensors subId | 255;100;0;15 | 'Leak was previously reported' color in format 'red;green;blue;blink' red, green, blue – 0..255; blink: 
 Example: 1c2='150;150;255;0'
 | 
| c3 | int[4] | sensors subId | 255;0;0;15 | On-leak color in format 'red;green;blue;blink' red, green, blue – 0..255; blink: 
 Example: 1c3='150;150;255;0'
 | 
| sens | int | sensors subId | 128 | Sensor sensitivity Example: 1sens='180'
 | 
- Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly.