HW settings

Name Type, range SUBID Default Description
c0 int[4] sensors subId 0;0;255;15 Normal state color in format 'red;green;blue;blink'

red, green, blue – 0..255; blink:

  • 0 – pulse
  • 1 – blink per 2 seconds
  • 2 – blink per second
  • 15 – constant glow

Example:

1c0='150;150;255;0'
c1 int[4] sensors subId 0;0;255;15 On-start color in format 'red;green;blue;blink'

red, green, blue – 0..255; blink:

  • 0 – pulse
  • 1 – blink per 2 seconds
  • 2 – blink per second
  • 15 – constant glow

Example:

1c1='150;150;255;0'
c2 int[4] sensors subId 255;100;0;15 'Leak was previously reported' color in format 'red;green;blue;blink'

red, green, blue – 0..255; blink:

  • 0 – pulse
  • 1 – blink per 2 seconds
  • 2 – blink per second
  • 15 – constant glow

Example:

1c2='150;150;255;0'
c3 int[4] sensors subId 255;0;0;15 On-leak color in format 'red;green;blue;blink'

red, green, blue – 0..255; blink:

  • 0 – pulse
  • 1 – blink per 2 seconds
  • 2 – blink per second
  • 15 – constant glow

Example:

1c3='150;150;255;0'
sens int sensors subId 128 Sensor sensitivity

Example:

1sens='180'
test int(0,1) sensors subId 1 0 - Disable the test signal to detect the presence of the sensor