This page contains changes which are not marked for translation.
Other languages:
English • ‎русский

Example of description in XML

1<item type="AC" name="AC" addr="123:4"/>

Additional parameters

Name type and variety description default value
path* string Path to script -
script-id string script id from the description for interface -
t-min number temperature low value 16
t-delta number temperature range 16
t-step number temperature step value 1
modes bit mask Mask of operation modes (fan, cool, dry, heat, auto) 0x1F
fans bit mask Mask of airflow mode (auto, 1, 2, 3, 4, 5, silent mode) 0x1F
vane-ver bit mask Mask of vertical fins mode (auto, top, top-center, center, center-bottom, bottom, swing) 0x7E
vane-hor bit mask Mask of horizontal fins mode (left, left-center, center, center-right, right, sides (low angle), sides (high angle), from sides to center) 0
temperature-sensors list list of valve temperature sensors -
t-outside addr addr of outside temperature sensors -
t-outside-treshold value critically low temperature treshold -
t-outside-hyst value critically low temperature hysteresis -

* – required fields

Device status upon status request (8 bytes)

Byte number Bit number Description
0 0
3
4-7
On/Off
Autostate
Mode:
0 – fan
1 – cool
2 – dry
3 – heat
4 – auto
1-2 8-23 Temperature setpoint
3 24-27








28-31







Horizontal vanes:
0 – left
1 – left-center
2 – center
3 – center-right
4 – right
5 – sides (low angle)
6 – sides (high angle)
7 – from sides to center
Vertical vanes:
0 – auto
1 – top
2 – top-center
3 – center
4 – center-bottom
5 – bottom
6 – swing
4 32-35







Fan:
0 – auto
1 – 1st speed
2 – 2nd speed
3 – 3rd speed
4 – 4th speed
5 – 5th speed
6 – silent mode
5-6 40-55 Current temperature
7 56-63 Flags
8 64-71 Errors

Possible variants of setting the status

1-byte

Byte Description
0 0 – off
1 – on
0xFF – Change the status for the opposite one

2-bytes

Byte Description
0 0xf
1 1 – Target +1
17 – Mode +1 cyclic
33 – Fan +1 cyclic
49 – Horizontal vanes +1 cyclic
65 – Vertical vanes +1 cyclic

3-bytes

Byte Description
0 0xf
1 16 – Mode (value)
18 – Mode (step)
32 – Fan (value)
34 – Fan (step)
48 – Horizontal vanes (value)
50 – Horizontal vanes (step)
64 – Vertical vanes (value)
66 – Vertical vanes (step)
80 - Set current temp
2 value – select value (for example status {0xf0, 32, 2} set fan 2)
step – set step (cyclic) (for example status {0xf0, 34, 2} set fan +2; status {0xf0, 34, -1} set fan -1)

4-bytes

Byte Description
0 0xf
1 0 – Target (value)
2 – Target (step)
2 fractional part of temperature (0-255)
3 integer part of temperature