Changes

380 bytes added ,  14:10, 9 January 2022
Marked this version for translation
Line 1: Line 1:  +
<languages/>
 +
<translate>
 +
<!--T:1-->
 
{{RevisionChanger | hasA = 1 | hasC = 1}}
 
{{RevisionChanger | hasA = 1 | hasC = 1}}
 +
{{Infobox module
 +
| name      = BW-010.C
 +
| image      = BW-010C.png
 +
| 010out    = 4
 +
| 010in      = 2
 +
| peakl      = 15mA
 +
| voltage    = 11.5...27.5 V DC
 +
| dim        = 45x42x14 mm
 +
}}
    +
==4-CHANNEL MODULE FOR DEVISES WITH 0-10V INPUT OR 0-10V OUTPUT== <!--T:2-->
   −
==4-CHANNEL MODULE FOR DEVISES WITH 0-10V INPUT OR 0-10V OUTPUT==
+
<!--T:3-->
 
   
This module allows connecting devices with 0-10V input or output interfaces
 
This module allows connecting devices with 0-10V input or output interfaces
 
to the Smart Home system.
 
to the Smart Home system.
    +
<!--T:4-->
 
<div class="caution">
 
<div class="caution">
 
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
 
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
Line 23: Line 36:  
</div>
 
</div>
   −
==Example of connection==
+
==Example of connection== <!--T:5-->
    +
<!--T:6-->
 
[[File:BW010C EXA.png|500px]]
 
[[File:BW010C EXA.png|500px]]
   −
==Module parameters==
+
==Module parameters== <!--T:7-->
    +
<!--T:8-->
 
{{ Mp
 
{{ Mp
 
| 010inqty        = 2
 
| 010inqty        = 2
Line 44: Line 59:  
}}
 
}}
   −
==Module installation and connection procedure==
+
==Module installation and connection procedure== <!--T:9-->
    +
<!--T:10-->
 
#Connect the interface connector.
 
#Connect the interface connector.
 
#Connect the CAN connector.
 
#Connect the CAN connector.
Line 51: Line 67:  
#Check all equipment for proper operation.
 
#Check all equipment for proper operation.
   −
==Module shut-off and deinstallation procedure==
+
==Module shut-off and deinstallation procedure== <!--T:11-->
    +
<!--T:12-->
 
#Disconnect the CAN connector.
 
#Disconnect the CAN connector.
 
#Disconnect the interface connector.
 
#Disconnect the interface connector.
   −
==HW settings==
+
==HW settings== <!--T:13-->
 
{|class="wikitable"
 
{|class="wikitable"
 
|-
 
|-
Line 84: Line 101:  
|}
 
|}
    +
<!--T:14-->
 
<syntaxhighlight lang="xml" line>
 
<syntaxhighlight lang="xml" line>
 
<item addr="377:1" auto-period="600" cfgid="170" name="Dimmer 1" type="dimmer-lamp"/>
 
<item addr="377:1" auto-period="600" cfgid="170" name="Dimmer 1" type="dimmer-lamp"/>
Line 94: Line 112:  
<item addr="377:98" cfgid="170" logic-ver="19" name="Temperature" system="yes" type="temperature-sensor"/>
 
<item addr="377:98" cfgid="170" logic-ver="19" name="Temperature" system="yes" type="temperature-sensor"/>
 
</syntaxhighlight>
 
</syntaxhighlight>
 +
</translate>
editor, translation-admin, translator
4,754

edits