Line 1: |
Line 1: |
| + | <languages/> |
| + | <translate> |
| + | <!--T:1--> |
| {{RevisionChanger | hasA = 1 | hasC = 1}} | | {{RevisionChanger | hasA = 1 | hasC = 1}} |
| {{Infobox module | | {{Infobox module |
Line 4: |
Line 7: |
| | image = BW-LC02C.png | | | image = BW-LC02C.png |
| | outCount = 2 | | | outCount = 2 |
− | | dimmOut =
| |
| | peakl = 2A | | | peakl = 2A |
− | | peakdl = | + | | inCount = 6 |
− | | dt = | + | | inB = 6 |
− | | inDisc = | + | | inLB = 5 |
− | | inDigit =
| |
| | voltage = 11.5...27.5 V DC | | | voltage = 11.5...27.5 V DC |
| | dim = 45x42x14 mm | | | dim = 45x42x14 mm |
| }} | | }} |
| | | |
− | ==2-CHANNEL ACTUATOR== | + | ==2-CHANNEL ACTUATOR== <!--T:2--> |
| | | |
| + | <!--T:3--> |
| Designed for AC/DC circuits commutation. Applicable for lighting and | | Designed for AC/DC circuits commutation. Applicable for lighting and |
| other electrical devices. It has 6 inputs for connecting buttons and reed switches. | | other electrical devices. It has 6 inputs for connecting buttons and reed switches. |
| | | |
− | ==Features== | + | ==Features== <!--T:4--> |
| *Compact size (only 16mm thickness) | | *Compact size (only 16mm thickness) |
| *6 inputs support: | | *6 inputs support: |
Line 32: |
Line 34: |
| **NC/NO locks | | **NC/NO locks |
| **Blinds | | **Blinds |
| + | **Сurtains |
| + | **Projector screens |
| + | **Valves |
| | | |
| + | WARNING! The module will stop working and will not be covered under warranty if used with high current or high inrush current with low-current settings |
| + | |
| + | <!--T:5--> |
| <div class="caution"> | | <div class="caution"> |
| CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. | | CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. |
Line 49: |
Line 57: |
| </div> | | </div> |
| | | |
− | ==Example of connection== | + | ==Example of connection== <!--T:6--> |
| | | |
| + | <!--T:7--> |
| [[File:LC02C EXA.png|700px]] | | [[File:LC02C EXA.png|700px]] |
| <br> | | <br> |
Line 56: |
Line 65: |
| [[File:LC02C OUT.png|400px]] | | [[File:LC02C OUT.png|400px]] |
| | | |
− | ==Module parameters== | + | ==Module parameters== <!--T:8--> |
| | | |
| + | <!--T:9--> |
| {{ Mp | | {{ Mp |
| | outqty = 2 | | | outqty = 2 |
Line 63: |
Line 73: |
| | buttons = 6 | | | buttons = 6 |
| | ledbuttons = 5 | | | ledbuttons = 5 |
− | | involtage = 100-250V | + | | involtage = 0-250V |
| | currtype = AC/DC | | | currtype = AC/DC |
| | maxperch = 2A | | | maxperch = 2A |
Line 78: |
Line 88: |
| | protection = IP40 | | | protection = IP40 |
| | temprange = -10 … +50 °C | | | temprange = -10 … +50 °C |
− | | size = 4U, 69x115x58 mm | + | | size = 45x42x14 mm |
− | | weight = 180 g | + | | weight = 25 g |
| }} | | }} |
| | | |
− | ==Module installation and connection procedure== | + | ==Module installation and connection procedure== <!--T:10--> |
| | | |
| + | <!--T:11--> |
| #Connect the outputs. | | #Connect the outputs. |
| #Connect the inputs. | | #Connect the inputs. |
Line 91: |
Line 102: |
| #Check all equipment for proper operation. | | #Check all equipment for proper operation. |
| | | |
− | ==Module shut-off and deinstallation procedure== | + | ==Module shut-off and deinstallation procedure== <!--T:12--> |
| | | |
| + | <!--T:13--> |
| #Disconnect the power from the load. | | #Disconnect the power from the load. |
| #Disconnect the CAN connector. | | #Disconnect the CAN connector. |
Line 98: |
Line 110: |
| #Disconnect the outputs. | | #Disconnect the outputs. |
| | | |
− | ==HW settings== | + | ==HW settings== <!--T:14--> |
| {|class="wikitable" | | {|class="wikitable" |
| |- | | |- |
Line 136: |
Line 148: |
| *'K'-Lock (short press), | | *'K'-Lock (short press), |
| *'N'-Lock (short press) Inverse, | | *'N'-Lock (short press) Inverse, |
| + | |
| + | WARNING! The module will stop working and will not be covered under warranty if used with high current or high inrush current with low-current settings |
| + | *'Y'-Low-current lamp, |
| + | *'T'-Low-current lamp Inverse, |
| *'F'-Low-current blinds, | | *'F'-Low-current blinds, |
| *'A'-Low-current blinds Inverse, | | *'A'-Low-current blinds Inverse, |
Line 167: |
Line 183: |
| |} | | |} |
| | | |
− | ==Input HW configuration== | + | ==Input HW configuration== <!--T:15--> |
| {| class="wikitable" | | {| class="wikitable" |
| |- | | |- |
Line 178: |
Line 194: |
| |Temperature Sensor||+|||||||||| | | |Temperature Sensor||+|||||||||| |
| |} | | |} |
| + | |
| + | <!--T:16--> |
| <syntaxhighlight lang="xml" line> | | <syntaxhighlight lang="xml" line> |
| <item addr="501:1" cfgid="171" name="Valve" type="valve" uniq_id="4169"/> | | <item addr="501:1" cfgid="171" name="Valve" type="valve" uniq_id="4169"/> |
Line 186: |
Line 204: |
| <item addr="501:98" cfgid="171" hw="out='V-' in='T--KD-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3999"/> | | <item addr="501:98" cfgid="171" hw="out='V-' in='T--KD-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3999"/> |
| </syntaxhighlight> | | </syntaxhighlight> |
| + | </translate> |