{{Infobox module
 +
| name      = BW-LC02.C
 +
| image      = BW-LC02C.png
 +
| outCount  = 2
 +
| peakl      = 2A
 +
| inCount    = 6
 +
| inB        = 6
 +
| inLB      = 5
 +
| voltage    = 11.5...27.5 V DC
 +
| dim        = 45x42x14 mm
 +
}}
    +
==2-CHANNEL ACTUATOR== <!--T:2-->
   −
==2-CHANNEL ACTUATOR==
+
<!--T:3-->
 
   
Designed for AC/DC circuits commutation. Applicable for lighting and
 
Designed for AC/DC circuits commutation. Applicable for lighting and
 
other electrical devices. It has 6 inputs for connecting buttons and reed switches.
 
other electrical devices. It has 6 inputs for connecting buttons and reed switches.
   −
==Features==
+
==Features== <!--T:4-->
 
*Compact size (only 16mm thickness)
 
*Compact size (only 16mm thickness)
 
*6 inputs support:
 
*6 inputs support:
Line 20: Line 34:  
**NC/NO locks
 
**NC/NO locks
 
**Blinds
 
**Blinds
 +
**Сurtains
 +
**Projector screens
 +
**Valves
 +
 +
WARNING! The module will stop working and will not be covered under warranty if used with high current or high inrush current with low-current settings
    +
<!--T:5-->
 
<div class="caution">
 
<div class="caution">
 
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
 
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
Line 37: Line 57:  
</div>
 
</div>
   −
==Example of connection==
+
==Example of connection== <!--T:6-->
    +
<!--T:7-->
 
[[File:LC02C EXA.png|700px]]
 
[[File:LC02C EXA.png|700px]]
 
<br>
 
<br>
Line 44: Line 65:  
[[File:LC02C OUT.png|400px]]
 
[[File:LC02C OUT.png|400px]]
   −
==Module parameters==
+
==Module parameters== <!--T:8-->
    +
<!--T:9-->
 
{{ Mp
 
{{ Mp
 
| outqty          = 2
 
| outqty          = 2
Line 51: Line 73:  
| buttons        = 6
 
| buttons        = 6
 
| ledbuttons      = 5
 
| ledbuttons      = 5
| involtage      = 100-250V
+
| involtage      = 0-250V
 
| currtype        = AC/DC
 
| currtype        = AC/DC
 
| maxperch        = 2A
 
| maxperch        = 2A
Line 66: Line 88:  
| protection      = IP40
 
| protection      = IP40
 
| temprange      = -10 … +50 °C
 
| temprange      = -10 … +50 °C
| size            = 4U, 69x115x58 mm
+
| size            = 45x42x14 mm
| weight          = 180 g
+
| weight          = 25 g
 
}}
 
}}
   −
==Module installation and connection procedure==
+
==Module installation and connection procedure== <!--T:10-->
    +
<!--T:11-->
 
#Connect the outputs.
 
#Connect the outputs.
 
#Connect the inputs.
 
#Connect the inputs.
Line 79: Line 102:  
#Check all equipment for proper operation.
 
#Check all equipment for proper operation.
   −
==Module shut-off and deinstallation procedure==
+
==Module shut-off and deinstallation procedure== <!--T:12-->
    +
<!--T:13-->
 
#Disconnect the power from the load.
 
#Disconnect the power from the load.
 
#Disconnect the CAN connector.
 
#Disconnect the CAN connector.
Line 86: Line 110:  
#Disconnect the outputs.
 
#Disconnect the outputs.
   −
==HW settings==
+
==HW settings== <!--T:14-->
 
{|class="wikitable"
 
{|class="wikitable"
 
|-
 
|-
Line 124: Line 148:  
*'K'-Lock (short press),
 
*'K'-Lock (short press),
 
*'N'-Lock (short press) Inverse,
 
*'N'-Lock (short press) Inverse,
 +
 +
WARNING! The module will stop working and will not be covered under warranty if used with high current or high inrush current with low-current settings
 +
*'Y'-Low-current lamp,
 +
*'T'-Low-current lamp Inverse,
 
*'F'-Low-current blinds,
 
*'F'-Low-current blinds,
 
*'A'-Low-current blinds Inverse,
 
*'A'-Low-current blinds Inverse,
Line 155: Line 183:  
|}
 
|}
   −
==Input HW configuration==
+
==Input HW configuration== <!--T:15-->
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 167: Line 195:  
|}
 
|}
    +
<!--T:16-->
 
<syntaxhighlight lang="xml" line>
 
<syntaxhighlight lang="xml" line>
 
<item addr="501:1" cfgid="171" name="Valve" type="valve" uniq_id="4169"/>
 
<item addr="501:1" cfgid="171" name="Valve" type="valve" uniq_id="4169"/>
Line 175: Line 204:  
<item addr="501:98" cfgid="171" hw="out='V-' in='T--KD-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3999"/>
 
<item addr="501:98" cfgid="171" hw="out='V-' in='T--KD-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3999"/>
 