Line 1: |
Line 1: |
| + | <languages/> |
| + | <translate> |
| + | <!--T:1--> |
| {{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}} | | {{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}} |
| {{Infobox module | | {{Infobox module |
Line 14: |
Line 17: |
| }} | | }} |
| | | |
− | ==10-CHANNEL HEATING CONTROLLER== | + | ==10-CHANNEL HEATING CONTROLLER== <!--T:2--> |
| | | |
| + | <!--T:3--> |
| The device is designed for controlling heating devices (radiators, floor heating, fan coil units, etc.). | | The device is designed for controlling heating devices (radiators, floor heating, fan coil units, etc.). |
| The device is equipped with 12 input channels for connection of temperature sensors (FW-FT or FW-TS). | | The device is equipped with 12 input channels for connection of temperature sensors (FW-FT or FW-TS). |
| | | |
− | ==Features== | + | ==Features== <!--T:4--> |
− | *10 outputs for NO/NC valves or contactors | + | *10 outputs for NO/NC/PWM valves |
− | *PWM outputs supported
| |
| *12 inputs for digital/analogue temperature sensors (FW-FT, FW-TS, NTC) | | *12 inputs for digital/analogue temperature sensors (FW-FT, FW-TS, NTC) |
| *Can to use temperature data from other modules | | *Can to use temperature data from other modules |
Line 28: |
Line 31: |
| *Built-in real time clock | | *Built-in real time clock |
| | | |
| + | <!--T:5--> |
| <div class="caution"> | | <div class="caution"> |
| CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. | | CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. |
Line 44: |
Line 48: |
| </div> | | </div> |
| | | |
− | ==Overview== | + | ==Overview== <!--T:6--> |
| | | |
| + | <!--T:7--> |
| [[File:HC10C VIEW.png|500px]] | | [[File:HC10C VIEW.png|500px]] |
| | | |
− | ==Example of connection== | + | ==Example of connection== <!--T:8--> |
| | | |
| + | <!--T:9--> |
| [[File:HC10C EXA.png|500px]] | | [[File:HC10C EXA.png|500px]] |
| | | |
− | ==Module dimensions== | + | ==Module dimensions== <!--T:10--> |
| | | |
| + | <!--T:11--> |
| [[File:HC10C DIM.png|500px]] | | [[File:HC10C DIM.png|500px]] |
| | | |
− | ==Module parameters== | + | ==Module parameters== <!--T:12--> |
| | | |
| + | <!--T:13--> |
| {{Mp | | {{Mp |
| | outqty = 10 | | | outqty = 10 |
| | inqty = 12 | | | inqty = 12 |
| + | | loadtype = NO / NC / PWM (0.4Hz) |
| + | | supportedsens = DS18B20 / NTC (7-15kOhm) |
| | involtage = 20-250V | | | involtage = 20-250V |
| | currtype = AC/DC | | | currtype = AC/DC |
Line 67: |
Line 77: |
| | power = 11.5 … 27.5 V DC from CAN | | | power = 11.5 … 27.5 V DC from CAN |
| | maxcur24v = 110 mA | | | maxcur24v = 110 mA |
− | | maxlen = 30m | + | | smaxlen = 30m |
| | bustype = CAN (4-wire) | | | bustype = CAN (4-wire) |
| | instalation = DIN-rail (EN 60715) | | | instalation = DIN-rail (EN 60715) |
Line 77: |
Line 87: |
| }} | | }} |
| | | |
− | ==Connection of high load device== | + | ==Connection of high load device== <!--T:14--> |
| | | |
| + | <!--T:15--> |
| {| class="wikitable" style="width:800px" ; | | {| class="wikitable" style="width:800px" ; |
| |- | | |- |
Line 87: |
Line 98: |
| |} | | |} |
| | | |
− | ==Input connector pinout== | + | ==Input connector pinout== <!--T:16--> |
| | | |
| + | <!--T:17--> |
| [[File:inputs.png|200px|Contactor]] | | [[File:inputs.png|200px|Contactor]] |
| | | |
| | | |
− | ==Example of sensors connection== | + | ==Example of sensors connection== <!--T:18--> |
| | | |
| + | <!--T:19--> |
| [[File:HC10Cexa3.png|200px|Contactor]] | | [[File:HC10Cexa3.png|200px|Contactor]] |
| | | |
− | ==Indication of module operation== | + | ==Indication of module operation== <!--T:20--> |
| ===Bootloader=== | | ===Bootloader=== |
| {{indication| textBBB= Waiting for bootloader command}} | | {{indication| textBBB= Waiting for bootloader command}} |
Line 109: |
Line 122: |
| }} | | }} |
| | | |
− | ==Module installation and connection procedure== | + | ==Module installation and connection procedure== <!--T:21--> |
| | | |
| + | <!--T:22--> |
| *Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base. | | *Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base. |
| *Connect the CAN connector. | | *Connect the CAN connector. |
Line 118: |
Line 132: |
| *Check all equipment for proper operation. | | *Check all equipment for proper operation. |
| | | |
− | ==Module shut-off and deinstallation procedure== | + | ==Module shut-off and deinstallation procedure== <!--T:23--> |
| | | |
| + | <!--T:24--> |
| *Disconnect the power from the load. | | *Disconnect the power from the load. |
| *Disconnect the input/output channels. | | *Disconnect the input/output channels. |
Line 125: |
Line 140: |
| *Remove the module from the DIN rail, releasing the latch at the bottom of the module base. | | *Remove the module from the DIN rail, releasing the latch at the bottom of the module base. |
| | | |
− | ==HW settings== | + | ==HW settings== <!--T:25--> |
| {| class="wikitable" | | {| class="wikitable" |
| |- | | |- |
Line 145: |
Line 160: |
| |out||char[10]||98||'HHHHHHHHHH'||Each char is responsible for the type of a particular channel | | |out||char[10]||98||'HHHHHHHHHH'||Each char is responsible for the type of a particular channel |
| *'D'- PWM output (frequency 0.4Hz); | | *'D'- PWM output (frequency 0.4Hz); |
| + | *'С'- Fancoil dimmer; |
| *'L'-Lamp; | | *'L'-Lamp; |
| *'M'-Lamp Inverse; | | *'M'-Lamp Inverse; |
Line 174: |
Line 190: |
| |} | | |} |
| | | |
| + | <!--T:26--> |
| <syntaxhighlight lang="xml" line=""> | | <syntaxhighlight lang="xml" line=""> |
| <item addr="348:1" cfgid="43" name="Jalousie" sub-type="120" type="jalousie" uniq_id="4097" hw="runtime=45"/> | | <item addr="348:1" cfgid="43" name="Jalousie" sub-type="120" type="jalousie" uniq_id="4097" hw="runtime=45"/> |
Line 202: |
Line 219: |
| <item addr="348:98" cfgid="43" hw="out='B-LG-KHJ--'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="4042"/> | | <item addr="348:98" cfgid="43" hw="out='B-LG-KHJ--'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="4042"/> |
| </syntaxhighlight> | | </syntaxhighlight> |
| + | </translate> |