Changes

Jump to navigation Jump to search
374 bytes added ,  11:06, 3 February 2022
Marked this version for translation
Line 1: Line 1:  +
<languages/>
 +
<translate>
 +
<!--T:1-->
 +
{{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}}
 
{{Infobox module
 
{{Infobox module
 
| name      = DW-HT07.B
 
| name      = DW-HT07.B
Line 13: Line 17:  
}}
 
}}
   −
{{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}}
+
==7-CHANNEL EXTENSION MODULE== <!--T:2-->
 
  −
==7-CHANNEL EXTENSION MODULE==
   
Has 7 outputs for connecting loads and 12 inputs for connecting
 
Has 7 outputs for connecting loads and 12 inputs for connecting
 
various sensors/buttons.
 
various sensors/buttons.
   −
==Features==
+
==Features== <!--T:3-->
    +
<!--T:4-->
 
*7 universal outputs support:
 
*7 universal outputs support:
 
**Lights
 
**Lights
Line 37: Line 40:  
*4 digital inputs for up to 8 temperature sensors
 
*4 digital inputs for up to 8 temperature sensors
    +
<!--T:5-->
 
<div class="caution">
 
<div class="caution">
 
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
 
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
Line 53: Line 57:  
</div>
 
</div>
   −
==Overview==
+
==Overview== <!--T:6-->
 
[[File:HT07B VIEW.png|500px]]
 
[[File:HT07B VIEW.png|500px]]
   −
==Example of connection==
+
==Example of connection== <!--T:7-->
 
[[File:HT07B EXA.png|500px]]
 
[[File:HT07B EXA.png|500px]]
   −
==Module dimensions==
+
==Module dimensions== <!--T:8-->
 
[[File:HT07B DIMM.png|500px]]
 
[[File:HT07B DIMM.png|500px]]
   −
==Module parameters==
+
==Module parameters== <!--T:9-->
    +
<!--T:10-->
 
{{ Mp
 
{{ Mp
 
| outqty          = 7
 
| outqty          = 7
Line 83: Line 88:  
}}
 
}}
   −
==Connectivity recommendations==
+
==Connectivity recommendations== <!--T:11-->
    +
<!--T:12-->
 
In order to protect the actuator and loads connected to it, installing a circuit breaker is recommended.
 
In order to protect the actuator and loads connected to it, installing a circuit breaker is recommended.
 
The nominal value of the circuit breaker should be calculated based on the maximum total load of connected
 
The nominal value of the circuit breaker should be calculated based on the maximum total load of connected
Line 92: Line 98:  
for each load.
 
for each load.
   −
==Connection of actuators==
+
==Connection of actuators== <!--T:13-->
    +
<!--T:14-->
 
<div class="caution"> Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.
 
<div class="caution"> Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.
 
If free (unused) channels remain in a given group after a curtain/jalousie/shutter actuator with low-voltage control or gate actuator has been connected to it, these channels need to be left unused. (Do not connect other devices to them!) </div>
 
If free (unused) channels remain in a given group after a curtain/jalousie/shutter actuator with low-voltage control or gate actuator has been connected to it, these channels need to be left unused. (Do not connect other devices to them!) </div>
   −
===Connection of the lights/electric contactor/heating thermal actuator===
+
===Connection of the lights/electric contactor/heating thermal actuator=== <!--T:15-->
    +
<!--T:16-->
 
[[File:lamps.png|200px]]<br>
 
[[File:lamps.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 106: Line 114:       −
===Connection of high load device===
+
===Connection of high load device=== <!--T:17-->
    +
<!--T:18-->
 
{| class="wikitable" style="width:800px";
 
{| class="wikitable" style="width:800px";
 
|-
 
|-
Line 116: Line 125:  
|}
 
|}
   −
===Connection of curtain/jalousie/shutter actuator with 220V force control===
+
===Connection of curtain/jalousie/shutter actuator with 220V force control=== <!--T:19-->
    +
<!--T:20-->
 
[[File:Pjalousie.png|200px]]<br>
 
[[File:Pjalousie.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 124: Line 134:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Connection of curtain/jalousie/shutter actuator with low-voltage control===
+
===Connection of curtain/jalousie/shutter actuator with low-voltage control=== <!--T:21-->
    +
<!--T:22-->
 
[[File:Ljalousie.png|200px]]<br>
 
[[File:Ljalousie.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 132: Line 143:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Connection of single-pole gate actuator===
+
===Connection of single-pole gate actuator=== <!--T:23-->
    +
<!--T:24-->
 
[[File:1pgate.png|200px]]<br>
 
[[File:1pgate.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 140: Line 152:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Connection of double-pole gate actuator===
+
===Connection of double-pole gate actuator=== <!--T:25-->
    +
<!--T:26-->
 
[[File:2pgate.png|200px]]<br>
 
[[File:2pgate.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 150: Line 163:       −
===Connection of single-pole water/gas supply valve===
+
===Connection of single-pole water/gas supply valve=== <!--T:27-->
    +
<!--T:28-->
 
[[File:1pvalve.png|200px]]<br>
 
[[File:1pvalve.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 158: Line 172:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Connection of double-pole water/gas supply valve===
+
===Connection of double-pole water/gas supply valve=== <!--T:29-->
    +
<!--T:30-->
 
[[File:2pvalve.png|200px]]<br>
 
[[File:2pvalve.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 166: Line 181:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Connection of fancoil control unit===
+
===Connection of fancoil control unit=== <!--T:31-->
    +
<!--T:32-->
 
[[File:fancoil.png|200px]]<br>
 
[[File:fancoil.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 174: Line 190:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Example of sensors connection===
+
==Indication of module operation== <!--T:33-->
 
  −
[[File:SensorsCon4.png|200px]]<br>
  −
2-wire connection recommended
  −
 
  −
==Indication of module operation==
  −
 
  −
===Bootloader===
  −
{{indication}}
     −
===Firmware mode===
+
<!--T:34-->
{{indicationfw
+
{{Indicationold}}
|err1 = 1
  −
|err2 = 1}}
     −
==Module installation and connection procedure==
+
==Module installation and connection procedure== <!--T:35-->
    +
<!--T:36-->
 
#Connect the outputs.
 
#Connect the outputs.
 
#Connect the inputs.
 
#Connect the inputs.
Line 198: Line 205:  
#Check all equipment for proper operation.
 
#Check all equipment for proper operation.
   −
==Module shut-off and deinstallation procedure==
+
==Module shut-off and deinstallation procedure== <!--T:37-->
    +
<!--T:38-->
 
#Disconnect the power from the load
 
#Disconnect the power from the load
 
#Disconnect the CAN connector.
 
#Disconnect the CAN connector.
Line 205: Line 213:  
#Disconnect the outputs.
 
#Disconnect the outputs.
   −
==HW Settings==
+
==HW Settings== <!--T:39-->
    +
<!--T:40-->
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 260: Line 269:  
*'N'-Third party leakage sensor;
 
*'N'-Third party leakage sensor;
 
*'M'-Motion, ​motion sensor;
 
*'M'-Motion, ​motion sensor;
 +
*'V'-Motion sensor (CW-MSD);
 
*'-'-none
 
*'-'-none
 
Example: in='KKKBBBLLLMMM'
 
Example: in='KKKBBBLLLMMM'
 
|}
 
|}
    +
<!--T:41-->
 
<syntaxhighlight lang="xml" line>
 
<syntaxhighlight lang="xml" line>
 
<item addr="479:1" auto-period="600" cfgid="42" name="Lamp" type="lamp" uniq_id="145" hw="def='ON'"/>
 
<item addr="479:1" auto-period="600" cfgid="42" name="Lamp" type="lamp" uniq_id="145" hw="def='ON'"/>
Line 287: Line 298:  
<item addr="479:98" cfgid="42" hw="out='LHG-B-R' in='CSKHLNMK-KM-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="144"/>
 
<item addr="479:98" cfgid="42" hw="out='LHG-B-R' in='CSKHLNMK-KM-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="144"/>
 
</syntaxhighlight>
 
</syntaxhighlight>
 +
</translate>
editor, Interface administrators, Administrators, translation-admin, translator
9,706

edits

Navigation menu