Changes

322 bytes removed ,  09:11, 27 July 2021
Line 72: Line 72:  
| involtage      = 0-250V
 
| involtage      = 0-250V
 
| currtype        = AC/DC
 
| currtype        = AC/DC
| maxperch        = 16A
+
| maxperch        = 8A
 +
| maxpergroup    = 20A
 +
| maxperdev      = 40A
 
| power          = 11.5 … 27.5 V DC from CAN
 
| power          = 11.5 … 27.5 V DC from CAN
 
| maxcur24v      = 150 mA
 
| maxcur24v      = 150 mA
Line 203: Line 205:  
|-
 
|-
 
|runtime||integer 0-100||1-7||15||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15
 
|runtime||integer 0-100||1-7||15||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15
|-
  −
|runtimeopen||integer 0-60000||Blinds subId||–||Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000
  −
|-
  −
|runtimeclose||integer 0-60000||Blinds subId||–||Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000
   
|-
 
|-
 
|hold||integer 0-10000||1-7||500||hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500
 
|hold||integer 0-10000||1-7||500||hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500
Line 219: Line 217:  
*'J'-Heating NO, valve-heating, normally open;
 
*'J'-Heating NO, valve-heating, normally open;
 
*'H'-Heating NC, valve-heating, normally closed;
 
*'H'-Heating NC, valve-heating, normally closed;
*'B'-Blinds (2 pole), jalousie/curtains;
+
*'B'-Blinds, jalousie/curtains(2 pole);
*'C'-Blinds Inverse (2 pole), jalousie/curtains, invert open-close;
+
*'C'-Blinds Inverse, jalousie/curtains, invert open-close(2 pole);
 
*'G'-Gate (2 pole), 2 pole gate;
 
*'G'-Gate (2 pole), 2 pole gate;
 
*'D'-Gate (2 pole) Inverse, 2 pole gate, invert open-close;
 
*'D'-Gate (2 pole) Inverse, 2 pole gate, invert open-close;
 
*'X'-Gate (1 pole /short press), 1 pole gate;
 
*'X'-Gate (1 pole /short press), 1 pole gate;
 
*'Z'-Gate (1 pole) Inverse, 1 pole gate, invert open-close;
 
*'Z'-Gate (1 pole) Inverse, 1 pole gate, invert open-close;
*'V'-Valve (2 pole), 2 pole valve;
+
*'V'-Valve (2 pole), 2 pole valve,;
 
*'W'-Valve (2 pole) Inverse, 2 pole valve, invert open-close;
 
*'W'-Valve (2 pole) Inverse, 2 pole valve, invert open-close;
*'R'-Valve (1 pole), 1 pole valve,;
+
*'R'-Valve (1 pole), 1 pole valve;
 
*'S'-Valve (1 pole) Inverse, 1 pole valve, invert open-close;
 
*'S'-Valve (1 pole) Inverse, 1 pole valve, invert open-close;
 
*'K'-Lock (short press);
 
*'K'-Lock (short press);
 
*'N'-Lock (short press) Inverse;
 
*'N'-Lock (short press) Inverse;
*'P'-Blinds (2 pole);
  −
*'O'-Blinds Inverse (2 pole), invert open-close;
   
*'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control;
 
*'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control;
 
*'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control;
 
*'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control;
Line 243: Line 239:     
<syntaxhighlight lang="xml" line="">
 
<syntaxhighlight lang="xml" line="">
<item addr="300:1" cfgid="47" hw="runtime=60" name="Jalousie" sub-type="120" type="jalousie" uniq_id="117"/>
+
<item addr="300:1" cfgid="61" hw="runtime=60" name="Jalousie" sub-type="120" type="jalousie" uniq_id="117"/>
<item addr="300:3" auto-period="600" cfgid="47" hw="def='ON'" name="Lamp" type="lamp" uniq_id="110"/>
+
<item addr="300:3" auto-period="600" cfgid="61" hw="def='ON'" name="Lamp" type="lamp" uniq_id="110"/>
<item addr="300:4" cfgid="47" hw="runtime=30" name="Gate" sub-type="120" type="gate" uniq_id="118"/>
+
<item addr="300:4" cfgid="61" hw="runtime=30" name="Gate" sub-type="120" type="gate" uniq_id="118"/>
<item addr="300:6" auto-period="600" cfgid="47" hw="hold=5000" name="Lamp" type="lamp" uniq_id="113"/>
+
<item addr="300:6" auto-period="600" cfgid="61" hw="hold=5000" name="Lamp" type="lamp" uniq_id="113"/>
<item addr="300:7" cfgid="47" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="119">
+
<item addr="300:7" cfgid="61" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="119">
 
     <automation name="Eco" temperature-level="16" uniq_id="120"/>
 
     <automation name="Eco" temperature-level="16" uniq_id="120"/>
 
     <automation name="Comfort" temperature-level="22" uniq_id="121"/>
 
     <automation name="Comfort" temperature-level="22" uniq_id="121"/>
 
     <automation name="Hot" temperature-level="25" uniq_id="122"/>
 
     <automation name="Hot" temperature-level="25" uniq_id="122"/>
 
</item>
 
</item>
<item addr="300:97" cfgid="47" name="Temperature" system="yes" type="temperature-sensor" uniq_id="106"/>
+
<item addr="300:97" cfgid="61" name="Temperature" system="yes" type="temperature-sensor" uniq_id="106"/>
<item addr="300:98" cfgid="47" hw="out='BLGKH'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="107"/>
+
<item addr="300:98" cfgid="61" hw="out='BLGKH'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="107"/>
 
</syntaxhighlight>
 
</syntaxhighlight>