Changes

Jump to navigation Jump to search
926 bytes added ,  08:38, 20 March 2023
no edit summary
Line 2: Line 2:  
<translate>
 
<translate>
 
<!--T:1-->
 
<!--T:1-->
{{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}}
   
{{Infobox module
 
{{Infobox module
| name      = DW-HT07.C
+
| name      = DW-RC12.B
 
| image      = DW-HT07C.png
 
| image      = DW-HT07C.png
| outCount  = 7
+
| outCount  = 12
 
| dimmOut    =  
 
| dimmOut    =  
 
| peakl      = 16A
 
| peakl      = 16A
 
| peakdl    =  
 
| peakdl    =  
 
| dt        =  
 
| dt        =  
| inDisc    = 12
+
| inDisc    = 24
 
| inDigit    = 4
 
| inDigit    = 4
 
| voltage    = 11.5...27.5 V DC
 
| voltage    = 11.5...27.5 V DC
Line 17: Line 16:  
}}
 
}}
   −
==7-CHANNEL EXTENSION MODULE== <!--T:2-->
+
==12-CHANNEL EXTENSION MODULE== <!--T:2-->
Has 7 outputs for connecting loads and 12 inputs for connecting
+
Has 12 outputs for connecting loads and 24 inputs for connecting
 
various sensors/buttons.
 
various sensors/buttons.
   Line 24: Line 23:     
<!--T:4-->
 
<!--T:4-->
*7 universal outputs support:
+
*12 universal outputs support:
 
**Lights
 
**Lights
 
**NC/NO heating valves
 
**NC/NO heating valves
Line 32: Line 31:  
**NC/NO locks
 
**NC/NO locks
 
**Fan coil units
 
**Fan coil units
*12 Discreet inputs that support:
+
*24 Discreet inputs that support:
 
**Buttons
 
**Buttons
 
**Switches
 
**Switches
Line 70: Line 69:  
<!--T:10-->
 
<!--T:10-->
 
{{ Mp
 
{{ Mp
| outqty          = 7
+
| outqty          = 12
 
| digitmaxlen    = 30 m
 
| digitmaxlen    = 30 m
| discinqty      = 12
+
| discinqty      = 24
 
| digitinqty      = 4
 
| digitinqty      = 4
 
| involtage      = 0-250V
 
| involtage      = 0-250V
Line 84: Line 83:  
| protection      = IP40
 
| protection      = IP40
 
| temprange      = -10 … +50 °C
 
| temprange      = -10 … +50 °C
| size            = 4U, 69x115x58 mm
+
| size            = 9U, 156x110x58 mm
| weight          = 255 g
+
| weight          = ??? g
 
}}
 
}}
   Line 231: Line 230:  
!Name!!Type, range!!SUBID!!Default!!Description
 
!Name!!Type, range!!SUBID!!Default!!Description
 
|-
 
|-
|runtime||integer 0-100||1-7||15||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15
+
|runtime||integer 0-100||1-12||15||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15
 
|-
 
|-
 
|runtimeopen||integer 0-60000||Blinds subId||-||Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000
 
|runtimeopen||integer 0-60000||Blinds subId||-||Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000
Line 237: Line 236:  
|runtimeclose||integer 0-60000||Blinds subId||-||Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000
 
|runtimeclose||integer 0-60000||Blinds subId||-||Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000
 
|-
 
|-
|hold||integer 0-10000||1-7||500||hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500
+
|hold||integer 0-10000||1-12||500||hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500
 
|-
 
|-
|def||string 'ON'||1-7||'OFF'||def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON'
+
|def||string 'ON'||1-12||'OFF'||def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON'
 
|-
 
|-
|stop||Char ‘R’||1-7||–||(for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is ‘r’ or ‘R’ then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., ‘d’ ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop=’r’
+
|stop||Char ‘R’||1-12||–||(for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is ‘r’ or ‘R’ then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., ‘d’ ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop=’r’
 
|-
 
|-
 
|out||char[7]||98||'LLLLLLL'||Each char is responsible for the type of a particular channel
 
|out||char[7]||98||'LLLLLLL'||Each char is responsible for the type of a particular channel
Line 266: Line 265:  
*'I'-FanCoil. Group5 (Lamp Toggle). For fancoil speed control;
 
*'I'-FanCoil. Group5 (Lamp Toggle). For fancoil speed control;
 
*'-'-none, nothing is connected.
 
*'-'-none, nothing is connected.
Example: out='LLHHHG-'
+
Example: out='LLMMHHB-FFFF'
 
|-
 
|-
 
|offset||float||SubID of OW temperature sensors||'0'||[+/- 0..39] – sensor values offset;
 
|offset||float||SubID of OW temperature sensors||'0'||[+/- 0..39] – sensor values offset;
Line 282: Line 281:  
*'V'-Motion sensor (CW-MSD);
 
*'V'-Motion sensor (CW-MSD);
 
*'-'-none
 
*'-'-none
Example: in='KKKBBBLLLMMM'
+
Example: in='MMM--LL-BBBBKKKKNSSSKKKK'
 
|}
 
|}
    
<!--T:44-->
 
<!--T:44-->
 
<syntaxhighlight lang="xml" line>
 
<syntaxhighlight lang="xml" line>
<item addr="479:1" auto-period="600" cfgid="42" name="Lamp" type="lamp" uniq_id="145" hw="def='ON'"/>
+
<item addr="372:1" auto-period="600" cfgid="193" hw="def='OFF'" name="Lamp 1" type="lamp"/>
<item addr="479:2" cfgid="42" name="Radiator" type="valve-heating" uniq_id="146" hw="def='ON'">
+
<item addr="372:2" auto-period="600" cfgid="193" hw="def='OFF'" name="Lamp 2" type="lamp"/>
  <automation name="Eco" temperature-level="16" uniq_id="147"/>
+
<item addr="372:3" auto-period="600" cfgid="193" hw="def='OFF'" name="Lamp 3" type="lamp"/>
  <automation name="Comfort" temperature-level="22" uniq_id="148"/>
+
<item addr="372:4" auto-period="600" cfgid="193" hw="def='OFF'" name="Lamp 4" type="lamp"/>
  <automation name="Hot" temperature-level="25" uniq_id="149"/>
+
<item addr="372:5" cfgid="193" hw="def='OFF'" name="Radiator" temperature-lag="0.2" type="valve-heating">
</item>
+
<automation name="Eco" temperature-level="16"/>
<item addr="479:3" cfgid="42" name="Gate" sub-type="120" type="gate" uniq_id="150" hw="runtime=25"/>
+
<automation name="Comfort" temperature-level="22"/>
<item addr="479:5" cfgid="42" name="Jalousie" sub-type="120" type="jalousie" uniq_id="151" hw="runtime=50"/>
+
<automation name="Hot" temperature-level="25"/>
<item addr="479:7" cfgid="42" name="Valve" type="valve" uniq_id="152" hw="def='ON'"/>
+
</item>
<item addr="479:11" cfgid="42" name="Switch" type="switch" uniq_id="153"/>
+
<item addr="372:6" cfgid="193" hw="def='OFF'" name="Radiator" temperature-lag="0.2" type="valve-heating">
<item addr="479:12" cfgid="42" name="Switch" type="switch" uniq_id="154"/>
+
<automation name="Eco" temperature-level="16"/>
<item addr="479:13" cfgid="42" name="Door" type="door-sensor" uniq_id="133"/>
+
<automation name="Comfort" temperature-level="22"/>
<item addr="479:14" cfgid="42" name="Door" type="door-sensor" uniq_id="134"/>
+
<automation name="Hot" temperature-level="25"/>
<item addr="479:15" cfgid="42" name="Leak" type="leak-sensor" uniq_id="155"/>
+
</item>
<item addr="479:16" cfgid="42" name="Leak" type="leak-sensor" uniq_id="156"/>
+
<item addr="372:7" cfgid="193" name="Jalousie" sub-type="120" type="jalousie"/>
<item addr="479:17" cfgid="42" name="Motion" type="motion-sensor" uniq_id="157"/>
+
<item addr="372:13" cfgid="193" name="Motion" type="motion-sensor"/>
<item addr="479:18" cfgid="42" name="Door" type="door-sensor" uniq_id="138"/>
+
<item addr="372:14" cfgid="193" name="Motion" type="motion-sensor"/>
<item addr="479:20" cfgid="42" name="Door" type="door-sensor" uniq_id="140"/>
+
<item addr="372:15" cfgid="193" name="Motion" type="motion-sensor"/>
<item addr="479:21" cfgid="42" name="Motion" type="motion-sensor" uniq_id="158"/>
+
<item addr="372:18" cfgid="193" name="Leak" type="leak-sensor"/>
<item addr="479:97" cfgid="42" name="Temperature" system="yes" type="temperature-sensor" uniq_id="143"/>
+
<item addr="372:19" cfgid="193" name="Leak" type="leak-sensor"/>
<item addr="479:98" cfgid="42" hw="out='LHG-B-R' in='CSKHLNMK-KM-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="144"/>
+
<item addr="372:21" cfgid="193" name="Switch 1" type="switch"/>
 +
<item addr="372:22" cfgid="193" name="Switch 2" type="switch"/>
 +
<item addr="372:23" cfgid="193" name="Switch 3" type="switch"/>
 +
<item addr="372:24" cfgid="193" name="Switch 4" type="switch"/>
 +
<item addr="372:25" cfgid="193" name="Door 1" type="door-sensor"/>
 +
<item addr="372:26" cfgid="193" name="Door 2" type="door-sensor"/>
 +
<item addr="372:27" cfgid="193" name="Door 3" type="door-sensor"/>
 +
<item addr="372:28" cfgid="193" name="Door 4" type="door-sensor"/>
 +
<item addr="372:29" cfgid="193" name="Leak" type="leak-sensor"/>
 +
<item addr="372:30" cfgid="193" name="Switch 5" type="switch"/>
 +
<item addr="372:31" cfgid="193" name="Switch 6" type="switch"/>
 +
<item addr="372:32" cfgid="193" name="Switch 7" type="switch"/>
 +
<item addr="372:33" cfgid="193" name="Door 5" type="door-sensor"/>
 +
<item addr="372:34" cfgid="193" name="Door 6" type="door-sensor"/>
 +
<item addr="372:35" cfgid="193" name="Door 7" type="door-sensor"/>
 +
<item addr="372:36" cfgid="193" name="Door 8" type="door-sensor"/>
 +
<item addr="372:50" cfgid="193" name="Fancoil" type="fancoil"/>
 +
<item addr="372:98" cfgid="193" hw="out='LLMMHHB-FFFF' in='MMM--LL-BBBBKKKKNSSSKKKK'" logic-ver="19" name="Temperature" sn="2516678146" system="yes" type="temperature-sensor"/>
 
</syntaxhighlight>
 