Changes

Jump to navigation Jump to search
374 bytes added ,  08:54, 7 April 2023
no edit summary
Line 4: Line 4:  
{{Infobox module
 
{{Infobox module
 
| name      = DW-RC12.B
 
| name      = DW-RC12.B
| image      = DW-HT07C.png
+
| image      = DW-RC12.B.png
 
| outCount  = 12
 
| outCount  = 12
 
| dimmOut    =  
 
| dimmOut    =  
Line 13: Line 13:  
| inDigit    = 4
 
| inDigit    = 4
 
| voltage    = 11.5...27.5 V DC
 
| voltage    = 11.5...27.5 V DC
| dim        = 4U, 69x115x58 mm
+
| dim        = 9U, 156x110x58 mm
 
}}
 
}}
   Line 19: Line 19:  
Has 12 outputs for connecting loads and 24 inputs for connecting
 
Has 12 outputs for connecting loads and 24 inputs for connecting
 
various sensors/buttons.
 
various sensors/buttons.
 +
 +
<!--T:23-->
 +
Module general view is shown in '''fig. 1'''
 +
 +
 +
<!--T:24-->
 +
[[File:DW-RC12.B dwg.png|700px|Fig. 1 Module general view]]
 +
 +
<br>
 +
 +
 +
    
==Features== <!--T:3-->
 
==Features== <!--T:3-->
Line 68: Line 80:  
| maxperch        = 16A
 
| maxperch        = 16A
 
| power          = 20.0 … 27.5 V DC from CAN
 
| power          = 20.0 … 27.5 V DC from CAN
| maxcur24v      = 140 mA
+
| maxcur24v      = 260 mA
 
| bustype        = CAN
 
| bustype        = CAN
 
| instalation    = DIN rail (EN 60715)
 
| instalation    = DIN rail (EN 60715)
Line 75: Line 87:  
| temprange      = -10 … +50 °C
 
| temprange      = -10 … +50 °C
 
| size            = 9U, 156x110x58 mm
 
| size            = 9U, 156x110x58 mm
| weight          = ??? g
+
| weight          = 400 g
 
}}
 
}}
   Line 88: Line 100:  
for each load.
 
for each load.
   −
==Connection of actuators== <!--T:13-->
+
<!--T:13-->
 +
Typical diagram of DW-RC12.B module connection is shown in '''fig. 2.'''
 +
<div style="clear: both">[[File:DW-RC12.B scheme.png|700px|Fig. 2]]</div>
 +
 
 +
==Connection of actuators== <!--T:14-->
   −
<!--T:14-->
+
<!--T:15-->
 
<div class="caution"> Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.
 
<div class="caution"> Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.
 
If free (unused) channels remain in a given group after a curtain/jalousie/shutter actuator with low-voltage control or gate actuator has been connected to it, these channels need to be left unused. (Do not connect other devices to them!) </div>
 
If free (unused) channels remain in a given group after a curtain/jalousie/shutter actuator with low-voltage control or gate actuator has been connected to it, these channels need to be left unused. (Do not connect other devices to them!) </div>
   −
===Connection of the lights/electric contactor/heating thermal actuator=== <!--T:15-->
+
===Connection of the lights/electric contactor/heating thermal actuator=== <!--T:16-->
   −
<!--T:16-->
+
<!--T:17-->
 
[[File:lamps.png|200px]]<br>
 
[[File:lamps.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 104: Line 120:       −
===Connection of high load device=== <!--T:17-->
+
===Connection of high load device=== <!--T:18-->
   −
<!--T:18-->
+
<!--T:19-->
 
{| class="wikitable" style="width:800px";
 
{| class="wikitable" style="width:800px";
 
|-
 
|-
Line 183: Line 199:     
<!--T:34-->
 
<!--T:34-->
[[File:SensorsCon4.png|200px]]<br>
+
[[File:SensorsRC12.png|200px]]<br>
 
2-wire connection recommended
 
2-wire connection recommended
   Line 250: Line 266:  
*'K'-Lock (short press);
 
*'K'-Lock (short press);
 
*'N'-Lock (short press) Inverse;
 
*'N'-Lock (short press) Inverse;
 +
*'P'-Blinds (2 pole);
 +
*'O'-Blinds Inverse (2 pole), invert open-close;
 
*'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control;
 
*'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control;
 
*'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control;
 
*'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control;
editor, Interface administrators, Administrators, translation-admin, translator
9,706

edits

Navigation menu