Changes

437 bytes added ,  06:20, 11 August 2022
m
no edit summary
Line 1: Line 1:  +
<languages/>
 +
<translate>
 +
<!--T:1-->
 
{{RevisionChanger | hasA = 1 | hasB = 1}}
 
{{RevisionChanger | hasA = 1 | hasB = 1}}
 
{{Infobox module
 
{{Infobox module
 
| name      = FW-WL.B
 
| name      = FW-WL.B
| image      = FW-WLB.jpg
+
| image      = FW-WLB.png
 
| voltage    = 9-12 V DC
 
| voltage    = 9-12 V DC
| dim        = 18x18x20 mm
+
| dim        = 57x47x22 mm
 
}}
 
}}
   −
==ON-THE-FLOOR LEAKAGE SENSOR==
+
==ON-THE-FLOOR LEAKAGE SENSOR== <!--T:2-->
    +
<!--T:3-->
 
The sensor is placed on the floor surface. It has an alarm light, which
 
The sensor is placed on the floor surface. It has an alarm light, which
 
changes from green to red if the sensor detects water on the floor.
 
changes from green to red if the sensor detects water on the floor.
 
Used together with DW-WL02 or BW-LSA modules.
 
Used together with DW-WL02 or BW-LSA modules.
   −
==Example of connection==
+
==Features== <!--T:4-->
 +
*Sensor presence detection
 +
*Customizing the indication colors
 +
*Adjusting the sensor sensitivity
 +
*Connections of several sensors to one bus
    +
==Example of connection== <!--T:5-->
 +
 +
<!--T:6-->
 
[[File:FWWLB EXA.jpg|400px]]
 
[[File:FWWLB EXA.jpg|400px]]
   −
==Connectors==
+
==Connectors== <!--T:7-->
    +
<!--T:8-->
 
[[File:FWWLB CON.png|400px]]
 
[[File:FWWLB CON.png|400px]]
   −
==Module parameters==
+
==Module parameters== <!--T:9-->
    +
<!--T:10-->
 
{{ Mp
 
{{ Mp
 
| power          = 9-12 V DC
 
| power          = 9-12 V DC
 
| maxcur24v      = 20 mA
 
| maxcur24v      = 20 mA
| compatible      = MF-10<br><br>DW-WL02/HTxx<br>BW-LSA
+
| compatible      = Metaforsa devices<br>DW-WL02/HTxx<br>BW-LSA
 
| instalation    = Free
 
| instalation    = Free
 
| case            = ABS
 
| case            = ABS
 
| protection      = IP64
 
| protection      = IP64
 
| temprange      = -10 … +50 °C
 
| temprange      = -10 … +50 °C
| size            = 18x18x20 mm
+
| size            = 57x47x22 mm
| weight          = 20g
+
| weight          = 35g
 
}}
 
}}
   −
==HW settings==
+
==HW settings== <!--T:11-->
 
{|class="wikitable"
 
{|class="wikitable"
 
|-
 
|-
Line 93: Line 106:  
sens='180'
 
sens='180'
 
</syntaxhighlight>
 
</syntaxhighlight>
 +
|-
 +
|test||int(0,1)||sensors subId||1||0 - Disable the test signal to detect the presence of the sensor
 
|}
 
|}
    +
<!--T:12-->
 
* Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly.
 
* Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly.
 
** Green and blue cannot be used at the same time. Green has priority.
 
** Green and blue cannot be used at the same time. Green has priority.
 +
</translate>
editor, Interface administrators, Administrators, translation-admin, translator
9,706

edits