While working with the system, you must strictly comply with all the requirements set out in this manual. Failure to comply may result in damage to the device, its failure, electric shock, fire and other fallout.
 
While working with the system, you must strictly comply with all the requirements set out in this manual. Failure to comply may result in damage to the device, its failure, electric shock, fire and other fallout.
 
The manufacturer reserves the right to make changes to this manual without prior notice. This manual is an integral part of the system and shall remain with the end-use customer.
 
The manufacturer reserves the right to make changes to this manual without prior notice. This manual is an integral part of the system and shall remain with the end-use customer.
 +
 +
<!--T:3.1-->
 +
‎<youtube>IC_-C7zVTPc</youtube>
    
==Features== <!--T:4-->
 
==Features== <!--T:4-->
Line 106: Line 110:  
|  Socket connectors ||  Magnetic reed switches
 
|  Socket connectors ||  Magnetic reed switches
 
|-
 
|-
|  Underfloor heating ||  Magnetic reed switches
+
|  Underfloor heating ||  Motion sensors
 
|-
 
|-
 
|  Curtain/gate actuators ||  Leakage sensors
 
|  Curtain/gate actuators ||  Leakage sensors
Line 183: Line 187:  
|-
 
|-
 
| Dimmer type || MOSFET  
 
| Dimmer type || MOSFET  
 +
|-
 +
| Dimmer load type || R,C
 
|-
 
|-
 
| Dimming type || trailing edge  
 
| Dimming type || trailing edge  
Line 206: Line 212:  
|Permissible humidity || 0 … 95% (non-condensing)  
 
|Permissible humidity || 0 … 95% (non-condensing)  
 
|-
 
|-
|Power supply || 23 … 27.5 V DC<br>24V, 0.75A Recommended
+
|Power supply || 12 … 27.5 V DC<br>24V, 0.75A Recommended
 
|-
 
|-
 
|Maximum demand || 0.5А  
 
|Maximum demand || 0.5А  
Line 254: Line 260:  
{| class="wikitable" style="clear:left;"
 
{| class="wikitable" style="clear:left;"
 
|-
 
|-
|1 || — connector for load application and power supply
+
|1 || — connector for load application
 
|-
 
|-
 
|2 || — connector for dimming-lamps application
 
|2 || — connector for dimming-lamps application
Line 313: Line 319:  
|[[File:OW.png|80px|frameless]] ||OneWire|| Digital sensors connection (temperature)<br>VCC — sensors power supply output +5V<br>OW1-OW4 — OneWire data buses<br>GND — common
 
|[[File:OW.png|80px|frameless]] ||OneWire|| Digital sensors connection (temperature)<br>VCC — sensors power supply output +5V<br>OW1-OW4 — OneWire data buses<br>GND — common
 
|-
 
|-
|[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| External modules connection for CAN-bus<br>VСС — 12V output for external devices power supply<br>GND — common<br>L — CAN-L data bus<br>H — CAN-H data bus
+
|[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| External modules connection for CAN-bus<br>VСС — 24V output for external devices power supply<br>GND — common<br>L — CAN-L data bus<br>H — CAN-H data bus
 
|}
 
|}
   Line 319: Line 325:  
{{indicationmfold}}
 
{{indicationmfold}}
   −
 
+
===System installation and assembly=== <!--T:31-->
===System installation and assembly=== <!--T:31-->
   
Before connecting the system, you must:
 
Before connecting the system, you must:
   Line 471: Line 476:     
<!--T:61-->
 
<!--T:61-->
Buttons and reed switches are connected to any free input in1-in16, while their second contact point is connected to GND point of the relevant METAFORSA module group, + 12V power outputs – not in use. The example of connection is shown in '''Fig. 14-16'''.
+
Buttons and reed switches are connected to any free input in1-in24, while their second contact point is connected to GND point of the relevant METAFORSA module group, + 12V power outputs – not in use. The example of connection is shown in '''Fig. 14-15'''.
 
{| style="width"700px"
 
{| style="width"700px"
 
|- style="tezt-align:center;"
 
|- style="tezt-align:center;"
 
|[[File:Buttons.png|300px|center]]<br>'''Fig14''' connection of buttons/switching units || [[File:Reed-sv.png|300px|center]]<br>'''Fig15''' connection of the magnetic reed switches (window/door position sensors)
 
|[[File:Buttons.png|300px|center]]<br>'''Fig14''' connection of buttons/switching units || [[File:Reed-sv.png|300px|center]]<br>'''Fig15''' connection of the magnetic reed switches (window/door position sensors)
 
|}
 
|}
      
====Connection of digital sensors==== <!--T:62-->
 
====Connection of digital sensors==== <!--T:62-->
Line 666: Line 670:  
Example: in='MMMMMMMMMMMMLLLLLLLLLLLL'
 
Example: in='MMMMMMMMMMMMLLLLLLLLLLLL'
 
12 motion sensors and 12 leak-sensors;
 
12 motion sensors and 12 leak-sensors;
in='BBBBBBBBSSSSSSRRRRSSRRRR'
+
in='BBBBBBBBSSSSSSBBBBSSSSSS'
8 buttons; 8 switches and 8 LED channels.
+
12 buttons; 12 switches.
 
|}
 
|}
  