Line 105: |
Line 105: |
| | Gate actuators || Temperature sensors | | | Gate actuators || Temperature sensors |
| |- | | |- |
− | | Water supply || LED strips | + | | Water supply || LED strips/3-4-5 channel RGB strips/WS2812B strips |
| |- | | |- |
− | | Heating valves || 3-4-5 channel RGB strips | + | | Heating valves || RS485 devices* |
− | |-
| |
− | | || WS2812B strips
| |
− | |-
| |
− | | || RS485 devices*
| |
| |} | | |} |
| <nowiki>*</nowiki> – Only for Metaforsa 3.plus | | <nowiki>*</nowiki> – Only for Metaforsa 3.plus |
Line 137: |
Line 133: |
| | Motion sensor CW-MSD || 3 pcs | | | Motion sensor CW-MSD || 3 pcs |
| |- | | |- |
− | | Leakage sensor FW-WL.A || 2 pcs | + | | Leakage sensor FW-WL.B || 2 pcs |
| |- | | |- |
− | | Temperature-sensitive element FW-TS.A || 4 pcs | + | | Temperature-sensitive element FW-TS || 4 pcs |
| |- | | |- |
| | Magnetic reed switch (window/door position sensor) || 4 pcs | | | Magnetic reed switch (window/door position sensor) || 4 pcs |
Line 146: |
Line 142: |
| |- | | |- |
| | Power supply cord || 1 pc | | | Power supply cord || 1 pc |
− | |-
| |
− | | Manual || 1 pc
| |
| |} | | |} |
| | | |
Line 221: |
Line 215: |
| |LAN wire type || UTP/FTP Cat 5E | | |LAN wire type || UTP/FTP Cat 5E |
| |- | | |- |
− | |LAN connection type || Connector RJ-45 | + | |LAN connection type || Connector RJ-45 |
| + | |- |
| + | |RS485 ports qty || 1*** |
| + | |- |
| + | |Data transfer speed || 1200-115200 b/s*** |
| |- | | |- |
| |Dimensional specifications || 9U, 156x90x58 mm | | |Dimensional specifications || 9U, 156x90x58 mm |
Line 235: |
Line 233: |
| <nowiki>*</nowiki> – Output channels should only be connected using amplifier which uses 5V PWM signal from IO output as input | | <nowiki>*</nowiki> – Output channels should only be connected using amplifier which uses 5V PWM signal from IO output as input |
| | | |
| + | <!--T:89--> |
| <nowiki>**</nowiki> – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors | | <nowiki>**</nowiki> – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors |
| + | |
| + | <!--T:90--> |
| + | <nowiki>***</nowiki> – Only for Metaforsa 3.plus |
| | | |
| ===General structure of the System=== <!--T:22--> | | ===General structure of the System=== <!--T:22--> |
Line 283: |
Line 285: |
| *connector (7) — expansion module connection. | | *connector (7) — expansion module connection. |
| | | |
| + | <!--T:91--> |
| The physical configuration and contact point assignment of each connector are shown in '''table 2'''. | | The physical configuration and contact point assignment of each connector are shown in '''table 2'''. |
| | | |
Line 303: |
Line 306: |
| |[[File:IOC_CONN.png|80px|frameless]] ||In1-14, In15-28 GND|| Controlling devices connection (buttons, LED buttons, magnetic reed switches, motion detectors, leakage sensors, temperature sensors, etc.): <br>In1 … In28 — logic inputs <br>GND — common | | |[[File:IOC_CONN.png|80px|frameless]] ||In1-14, In15-28 GND|| Controlling devices connection (buttons, LED buttons, magnetic reed switches, motion detectors, leakage sensors, temperature sensors, etc.): <br>In1 … In28 — logic inputs <br>GND — common |
| |- | | |- |
− | |[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| External modules connection for CAN-bus<br>VСС — 12V output for external devices power supply<br>GND — common<br>L — CAN-L data bus<br>H — CAN-H data bus | + | |[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| External modules connection for CAN-bus<br>VСС — 24V output for external devices power supply<br>GND — common<br>L — CAN-L data bus<br>H — CAN-H data bus |
| |} | | |} |
| | | |
Line 309: |
Line 312: |
| {{indicationmfold}} | | {{indicationmfold}} |
| | | |
− | ===System installation and assembly=== <!--T:31--> | + | ===System installation and assembly=== <!--T:31--> |
| Before connecting the system, you must: | | Before connecting the system, you must: |
| | | |
Line 428: |
Line 431: |
| ====Connection of motion sensors/leakage sensors==== <!--T:54--> | | ====Connection of motion sensors/leakage sensors==== <!--T:54--> |
| | | |
− | The motion sensors/leakage sensors should be connected to any free input in1-in28; in these conditions their power is connected to the contact points of +12V and GND of the relevant group. The example of connection is shown in '''Fig.11'''. | + | <!--T:92--> |
| + | The motion sensors/leakage sensors should be connected to any free input in1-in28; in these conditions their power is connected to the contact points of +5V and GND of the relevant group. The example of connection is shown in '''Fig.11'''. |
| | | |
| <!--T:55--> | | <!--T:55--> |
Line 438: |
Line 442: |
| ====Connection of buttons/switches/magnetic reed switches==== <!--T:56--> | | ====Connection of buttons/switches/magnetic reed switches==== <!--T:56--> |
| | | |
| + | <!--T:93--> |
| Buttons and reed switches are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in '''Fig. 12-13'''. | | Buttons and reed switches are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in '''Fig. 12-13'''. |
| | | |
Line 640: |
Line 645: |
| *'z' - WS2812B -string | | *'z' - WS2812B -string |
| | | |
| + | <!--T:94--> |
| *'e' - led-button inverse | | *'e' - led-button inverse |
| *'d' - led-button | | *'d' - led-button |
Line 653: |
Line 659: |
| *'r' - thermo-resistor | | *'r' - thermo-resistor |
| *'t' - DALLAS | | *'t' - DALLAS |
− |
| |
| *'-' - none | | *'-' - none |
| Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' | | Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |
| |- | | |- |
− | |colspan="2"|'''Only for Metaforsa 3.plus''' | + | |hw||string||98||-||hw="...", where |
| + | *pwm_invert – PWM inverting [1, 0]; |
| + | *lbn_bright – brightness of led buttons, range (0 - 255); |
| + | *f – by default PWM frequency is 1000, range (1 - 5000). |
| + | Example: |
| + | <syntaxhighlight lang="xml" line> |
| + | hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" |
| + | </syntaxhighlight> |
| + | |- |
| + | |colspan="3"|'''Only for Metaforsa 3.plus''' |
| |- | | |- |
| |cfg||string||98||9600/8N1||cfg='SPEED/BPS', where | | |cfg||string||98||9600/8N1||cfg='SPEED/BPS', where |