Changes

m
Add HW table
Line 105: Line 105:  
|  Gate actuators || Temperature sensors
 
|  Gate actuators || Temperature sensors
 
|-
 
|-
|  Water supply || LED strips
+
|  Water supply || LED strips/3-4-5 channel RGB strips/WS2812B strips
 
|-
 
|-
|  Heating valves || 3-4-5 channel RGB strips
+
|  Heating valves || RS485 devices*
|-
  −
|  || WS2812B strips
  −
|-
  −
|| RS485 devices*
   
|}
 
|}
 
<nowiki>*</nowiki> – Only for Metaforsa 3.plus
 
<nowiki>*</nowiki> – Only for Metaforsa 3.plus
Line 137: Line 133:  
| Motion sensor CW-MSD || 3 pcs
 
| Motion sensor CW-MSD || 3 pcs
 
|-
 
|-
| Leakage sensor FW-WL.A || 2 pcs
+
| Leakage sensor FW-WL.B || 2 pcs
 
|-
 
|-
| Temperature-sensitive element FW-TS.A || 4 pcs
+
| Temperature-sensitive element FW-TS || 4 pcs
 
|-
 
|-
 
| Magnetic reed switch (window/door position sensor) || 4 pcs
 
| Magnetic reed switch (window/door position sensor) || 4 pcs
Line 146: Line 142:  
|-
 
|-
 
| Power supply cord || 1 pc
 
| Power supply cord || 1 pc
|-
  −
| Manual || 1 pc
   
|}
 
|}
   Line 221: Line 215:  
|LAN wire type || UTP/FTP Cat 5E
 
|LAN wire type || UTP/FTP Cat 5E
 
|-
 
|-
|LAN connection type || Connector RJ-45  
+
|LAN connection type || Connector RJ-45
 +
|-
 +
|RS485 ports qty || 1***
 +
|-
 +
|Data transfer speed || 1200-115200 b/s***
 
|-
 
|-
 
|Dimensional specifications || 9U, 156x90x58 mm  
 
|Dimensional specifications || 9U, 156x90x58 mm  
Line 235: Line 233:  
<nowiki>*</nowiki> – Output channels should only be connected using amplifier which uses 5V PWM signal from IO output as input
 
<nowiki>*</nowiki> – Output channels should only be connected using amplifier which uses 5V PWM signal from IO output as input
    +
<!--T:89-->
 
<nowiki>**</nowiki> – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors
 
<nowiki>**</nowiki> – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors
 +
 +
<!--T:90-->
 +
<nowiki>***</nowiki> – Only for Metaforsa 3.plus
    
===General structure of the System=== <!--T:22-->  
 
===General structure of the System=== <!--T:22-->  
Line 283: Line 285:  
*connector (7) — expansion module connection.
 
*connector (7) — expansion module connection.
    +
<!--T:91-->
 
The physical configuration and contact point assignment of each connector are shown in '''table 2'''.
 
The physical configuration and contact point assignment of each connector are shown in '''table 2'''.
   Line 303: Line 306:  
|[[File:IOC_CONN.png|80px|frameless]] ||In1-14, In15-28 GND|| Controlling devices connection (buttons, LED buttons, magnetic reed switches, motion detectors, leakage sensors, temperature sensors, etc.): <br>In1 … In28 — logic inputs <br>GND — common
 
|[[File:IOC_CONN.png|80px|frameless]] ||In1-14, In15-28 GND|| Controlling devices connection (buttons, LED buttons, magnetic reed switches, motion detectors, leakage sensors, temperature sensors, etc.): <br>In1 … In28 — logic inputs <br>GND — common
 
|-
 
|-
|[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| External modules connection for CAN-bus<br>VСС — 12V output for external devices power supply<br>GND — common<br>L — CAN-L data bus<br>H — CAN-H data bus
+
|[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| External modules connection for CAN-bus<br>VСС — 24V output for external devices power supply<br>GND — common<br>L — CAN-L data bus<br>H — CAN-H data bus
 
|}
 
|}
   Line 309: Line 312:  
{{indicationmfold}}
 
{{indicationmfold}}
   −
===System installation and assembly=== <!--T:31-->
+
===System installation and assembly=== <!--T:31-->
 
Before connecting the system, you must:
 
Before connecting the system, you must:
   Line 428: Line 431:  
====Connection of motion sensors/leakage sensors==== <!--T:54-->
 
====Connection of motion sensors/leakage sensors==== <!--T:54-->
   −
The motion sensors/leakage sensors should be connected to any free input in1-in28; in these conditions their power is connected to the contact points of +12V and GND of the relevant group. The example of connection is shown in '''Fig.11'''.
+
<!--T:92-->
 +
The motion sensors/leakage sensors should be connected to any free input in1-in28; in these conditions their power is connected to the contact points of +5V and GND of the relevant group. The example of connection is shown in '''Fig.11'''.
    
<!--T:55-->
 
<!--T:55-->
Line 438: Line 442:  
====Connection of buttons/switches/magnetic reed switches==== <!--T:56-->
 
====Connection of buttons/switches/magnetic reed switches==== <!--T:56-->
    +
<!--T:93-->
 
Buttons and reed switches are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in '''Fig. 12-13'''.
 
Buttons and reed switches are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in '''Fig. 12-13'''.
   Line 640: Line 645:  
*'z' - WS2812B -string
 
*'z' - WS2812B -string
    +
<!--T:94-->
 
*'e' - led-button inverse
 
*'e' - led-button inverse
 
*'d' - led-button
 
*'d' - led-button
Line 653: Line 659:  
*'r' - thermo-resistor
 
*'r' - thermo-resistor
 
*'t' - DALLAS
 
*'t' - DALLAS
   
*'-' - none
 
*'-' - none
 
Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
 
Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
 +
|-
 +
|hw||string||98||-||hw="...", where
 +
*pwm_invert – PWM inverting [1, 0];
 +
*lbn_bright – brightness of led buttons, range (0 - 255);
 +
*f – by default PWM frequency is 1000, range (1 - 5000).
 +
Example:
 +
<syntaxhighlight lang="xml" line>
 +
hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
 +
</syntaxhighlight>
 
|-
 
|-
 
|colspan="3"|'''Only for Metaforsa 3.plus'''
 
|colspan="3"|'''Only for Metaforsa 3.plus'''
editor, Interface administrators, Administrators, translation-admin, translator
9,706