Changes

m
Add HW table
Line 133: Line 133:  
| Motion sensor CW-MSD || 3 pcs
 
| Motion sensor CW-MSD || 3 pcs
 
|-
 
|-
| Leakage sensor FW-WL.A || 2 pcs
+
| Leakage sensor FW-WL.B || 2 pcs
 
|-
 
|-
| Temperature-sensitive element FW-TS.A || 4 pcs
+
| Temperature-sensitive element FW-TS || 4 pcs
 
|-
 
|-
 
| Magnetic reed switch (window/door position sensor) || 4 pcs
 
| Magnetic reed switch (window/door position sensor) || 4 pcs
Line 142: Line 142:  
|-
 
|-
 
| Power supply cord || 1 pc
 
| Power supply cord || 1 pc
|-
  −
| Manual || 1 pc
   
|}
 
|}
   Line 235: Line 233:  
<nowiki>*</nowiki> – Output channels should only be connected using amplifier which uses 5V PWM signal from IO output as input
 
<nowiki>*</nowiki> – Output channels should only be connected using amplifier which uses 5V PWM signal from IO output as input
    +
<!--T:89-->
 
<nowiki>**</nowiki> – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors
 
<nowiki>**</nowiki> – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors
    +
<!--T:90-->
 
<nowiki>***</nowiki> – Only for Metaforsa 3.plus
 
<nowiki>***</nowiki> – Only for Metaforsa 3.plus
   Line 285: Line 285:  
*connector (7) — expansion module connection.
 
*connector (7) — expansion module connection.
    +
<!--T:91-->
 
The physical configuration and contact point assignment of each connector are shown in '''table 2'''.
 
The physical configuration and contact point assignment of each connector are shown in '''table 2'''.
   Line 305: Line 306:  
|[[File:IOC_CONN.png|80px|frameless]] ||In1-14, In15-28 GND|| Controlling devices connection (buttons, LED buttons, magnetic reed switches, motion detectors, leakage sensors, temperature sensors, etc.): <br>In1 … In28 — logic inputs <br>GND — common
 
|[[File:IOC_CONN.png|80px|frameless]] ||In1-14, In15-28 GND|| Controlling devices connection (buttons, LED buttons, magnetic reed switches, motion detectors, leakage sensors, temperature sensors, etc.): <br>In1 … In28 — logic inputs <br>GND — common
 
|-
 
|-
|[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| External modules connection for CAN-bus<br>VСС — 12V output for external devices power supply<br>GND — common<br>L — CAN-L data bus<br>H — CAN-H data bus
+
|[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| External modules connection for CAN-bus<br>VСС — 24V output for external devices power supply<br>GND — common<br>L — CAN-L data bus<br>H — CAN-H data bus
 
|}
 
|}
   Line 311: Line 312:  
{{indicationmfold}}
 
{{indicationmfold}}
   −
===System installation and assembly=== <!--T:31-->
+
===System installation and assembly=== <!--T:31-->
 
Before connecting the system, you must:
 
Before connecting the system, you must:
   Line 430: Line 431:  
====Connection of motion sensors/leakage sensors==== <!--T:54-->
 
====Connection of motion sensors/leakage sensors==== <!--T:54-->
   −
The motion sensors/leakage sensors should be connected to any free input in1-in28; in these conditions their power is connected to the contact points of +12V and GND of the relevant group. The example of connection is shown in '''Fig.11'''.
+
<!--T:92-->
 +
The motion sensors/leakage sensors should be connected to any free input in1-in28; in these conditions their power is connected to the contact points of +5V and GND of the relevant group. The example of connection is shown in '''Fig.11'''.
    
<!--T:55-->
 
<!--T:55-->
Line 440: Line 442:  
====Connection of buttons/switches/magnetic reed switches==== <!--T:56-->
 
====Connection of buttons/switches/magnetic reed switches==== <!--T:56-->
    +
<!--T:93-->
 
Buttons and reed switches are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in '''Fig. 12-13'''.
 
Buttons and reed switches are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in '''Fig. 12-13'''.
   Line 642: Line 645:  
*'z' - WS2812B -string
 
*'z' - WS2812B -string
    +
<!--T:94-->
 
*'e' - led-button inverse
 
*'e' - led-button inverse
 
*'d' - led-button
 
*'d' - led-button
Line 655: Line 659:  
*'r' - thermo-resistor
 
*'r' - thermo-resistor
 
*'t' - DALLAS
 
*'t' - DALLAS
   
*'-' - none
 
*'-' - none
 
Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
 
Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
 +
|-
 +
|hw||string||98||-||hw="...", where
 +
*pwm_invert – PWM inverting [1, 0];
 +
*lbn_bright – brightness of led buttons, range (0 - 255);
 +
*f – by default PWM frequency is 1000, range (1 - 5000).
 +
Example:
 +
<syntaxhighlight lang="xml" line>
 +
hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
 +
</syntaxhighlight>
 
|-
 
|-
 
|colspan="3"|'''Only for Metaforsa 3.plus'''
 
|colspan="3"|'''Only for Metaforsa 3.plus'''