Line 233: |
Line 233: |
| <nowiki>*</nowiki> – Output channels should only be connected using amplifier which uses 5V PWM signal from IO output as input | | <nowiki>*</nowiki> – Output channels should only be connected using amplifier which uses 5V PWM signal from IO output as input |
| | | |
| + | <!--T:89--> |
| <nowiki>**</nowiki> – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors | | <nowiki>**</nowiki> – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors |
| | | |
| + | <!--T:90--> |
| <nowiki>***</nowiki> – Only for Metaforsa 3.plus | | <nowiki>***</nowiki> – Only for Metaforsa 3.plus |
| | | |
Line 283: |
Line 285: |
| *connector (7) — expansion module connection. | | *connector (7) — expansion module connection. |
| | | |
| + | <!--T:91--> |
| The physical configuration and contact point assignment of each connector are shown in '''table 2'''. | | The physical configuration and contact point assignment of each connector are shown in '''table 2'''. |
| | | |
Line 309: |
Line 312: |
| {{indicationmfold}} | | {{indicationmfold}} |
| | | |
− | ===System installation and assembly=== <!--T:31--> | + | ===System installation and assembly=== <!--T:31--> |
| Before connecting the system, you must: | | Before connecting the system, you must: |
| | | |
Line 428: |
Line 431: |
| ====Connection of motion sensors/leakage sensors==== <!--T:54--> | | ====Connection of motion sensors/leakage sensors==== <!--T:54--> |
| | | |
| + | <!--T:92--> |
| The motion sensors/leakage sensors should be connected to any free input in1-in28; in these conditions their power is connected to the contact points of +12V and GND of the relevant group. The example of connection is shown in '''Fig.11'''. | | The motion sensors/leakage sensors should be connected to any free input in1-in28; in these conditions their power is connected to the contact points of +12V and GND of the relevant group. The example of connection is shown in '''Fig.11'''. |
| | | |
Line 438: |
Line 442: |
| ====Connection of buttons/switches/magnetic reed switches==== <!--T:56--> | | ====Connection of buttons/switches/magnetic reed switches==== <!--T:56--> |
| | | |
| + | <!--T:93--> |
| Buttons and reed switches are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in '''Fig. 12-13'''. | | Buttons and reed switches are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in '''Fig. 12-13'''. |
| | | |
Line 640: |
Line 645: |
| *'z' - WS2812B -string | | *'z' - WS2812B -string |
| | | |
| + | <!--T:94--> |
| *'e' - led-button inverse | | *'e' - led-button inverse |
| *'d' - led-button | | *'d' - led-button |
Line 654: |
Line 660: |
| *'t' - DALLAS | | *'t' - DALLAS |
| | | |
| + | <!--T:95--> |
| *'-' - none | | *'-' - none |
| Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' | | Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |