Changes

Created page with "==HW Indstillinger== {| class="wikitable" |- !Navn!!Type, område!!SUBID!!Standard!!Beskrivelse |- |runtime||integer 0-100 || 1-10 || 15 ||runtime er åbnings-/lukketiden i se..."
Line 511: Line 511:  
*kontroller integriteten af CAN-ledningerne, spændingsforsyning på modulerne.
 
*kontroller integriteten af CAN-ledningerne, spændingsforsyning på modulerne.
   −
==HW Settings==
+
==HW Indstillinger==
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
!Name!!Type, range!!SUBID!!Default!!Description
+
!Navn!!Type, område!!SUBID!!Standard!!Beskrivelse
 
|-
 
|-
|runtime||integer 0-100 || 1-10 || 15 ||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole);  
+
|runtime||integer 0-100 || 1-10 || 15 ||runtime er åbnings-/lukketiden i sekunder, bruges til jalousi, gate, ventil(2 polet);
<br>Example: runtime=15
+
<br>Eksempel: runtime=15
 
|-
 
|-
|runtimeopen||integer 0-60000||Blinds subId || ||Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000
+
|runtimeopen||integer 0-60000||Blinds subId || ||Runtimeopen er åbningstiden i millisekunder, bruges til persienner; Eksempel: runtimeopen=15000
 
|-
 
|-
|runtimeclose||integer 0-60000||Blinds subId|| ||Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000
+
|runtimeclose||integer 0-60000||Blinds subId|| ||Runtimeclose er lukketiden i millisekunder, bruges til persienner; Eksempel: runtimeclose=15000
 
|-
 
|-
|hold||integer 0-10000||1-10||500||hold is the bridging time in milliseconds, is used for gate and jalousie (by default hold is the same as runtime for jalousie and gate), lock; Example: hold=3500
+
|hold||integer 0-10000||1-10||500||hold er bro-tiden i millisekunder, bruges til gate og jalousi (hold er som standard det samme som runtime for jalousi og gate), lås; Eksempel: hold=3500
 
|-
 
|-
|def||string 'ON'||1-10||'OFF'||def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON'
+
|def||string 'ON'||1-10||'OFF'||def er elementstatus indstillet efter genstart, bruges til lampe, varme, ventil(1 pol); Eksempel: def='ON'
 
|-
 
|-
|stop||Char ‘R’||1-7||–||(for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is ‘r’ or ‘R’ then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., ‘d’ ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop=’r’
+
|stop||Char ‘R’||1-7||–||(for 2-polet låge og persienner) Hvis det erklæres ved stop-kommando under bevægelsen, vises den samme impuls, som den var i begyndelsen af bevægelsen. Pol, som stop-impulserne dannes, er defineret af parameteren Stop-værdi. Hvis det er 'r' eller 'R', produceres stop-impuls modsat start-impuls-polen. Hvis en anden værdi decareres (f.eks. 'd'), så er stop-impulsen på samme pol. Hvis en Runtime gik efter begyndelsen af bevægelsen, dannes stop-impulsen ikke. Eksempel: stop=’r’
 
|-
 
|-
|out||char[10]||98||'LLLLHHHHP-'||Each char is responsible for the type of a particular channel
+
|out||char[10]||98||'LLLLHHHHP-'||Hver char er ansvarlig for typen af en bestemt kanal
*'L'-Lamp;
+
*'L'-Lampe;
*'M'-Lamp Inverse;
+
*'M'-Lampe omvendt;
*'J'-Heating NO, valve-heating, normally open;
+
*'J'-Opvarmning NO, ventil-opvarmning, normalt åben;
*'H'-Heating NC, valve-heating, normally closed;
+
*'H'-Opvarmning NC, ventil-varme, normalt lukket;
*'B'-Blinds (2 pole), jalousie/curtains;
+
*'B'-gardiner (2 polet), jalousie/gardiner;
*'C'-Blinds Inverse (2 pole), jalousie/curtains, invert open-close;
+
*'C'-Blinds Inverse (2 polet), jalousie/gardiner, vend åben-luk;
*'G'-Gate (2 pole), 2 pole gate;
+
*'G'-Gate (2 polet), 2 polet port;
*'D'-Gate (2 pole) Inverse, 2 pole gate, invert open-close;
+
*'D'-Gate (2 polet) Invers, 2 polet gate, vend åben-luk;
*'X'-Gate (1 pole /short press), 1 pole gate;
+
*'X'-Gate (1 pol/kort tryk), 1 pol port;
*'Z'-Gate (1 pole) Inverse, 1 pole gate, invert open-close;
+
*'Z'-Gate (1 pol) Omvendt, 1 polet port, vend åben-luk;
*'V'-Valve (2 pole), 2 pole valve;
+
*'V'-Ventil (2 polet), 2 polet ventil;
*'W'-Valve (2 pole) Inverse, 2 pole valve, invert open-close;
+
*'W'-Ventil (2-polet) Omvendt, 2-polet ventil, inverter åben-luk;
*'R'-Valve (1 pole), 1 pole valve,;
+
*'R'-Ventil (1 pol), 1 pol ventil,;
*'S'-Valve (1 pole) Inverse, 1 pole valve, invert open-close;
+
*'S'-Ventil (1 pol) Omvendt, 1 polet ventil, inverter åben-luk;
*'K'-Lock (short press);
+
*'K'-Lock (kort tryk);
*'N'-Lock (short press) Inverse;
+
*'N'-Lock (kort tryk) Omvendt;
*'P'-Blinds (2 pole);
+
*'P'-Blinds (2 polet);
*'O'-Blinds Inverse (2 pole), invert open-close;
+
*'O'-Blinds Inverse (2 polet), vend åben-luk;
*'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control;
+
*'F'-FanCoil. Gruppe1 (Lampeskift). Til fancoil hastighedskontrol;
*'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control;
+
*'E'-FanCoil. Gruppe2 (Lampeskift). Til fancoil hastighedskontrol;
*'Q'-FanCoil. Group3 (Lamp Toggle). For fancoil speed control;
+
*'Q'-FanCoil. Gruppe3 (Lampeskift). Til fancoil hastighedskontrol;
*'U'-FanCoil. Group4 (Lamp Toggle). For fancoil speed control;
+
*'U'-FanCoil. Gruppe4 (Lampeskift). Til fancoil hastighedskontrol;
*'I'-FanCoil. Group5 (Lamp Toggle). For fancoil speed control;
+
*'I'-FanCoil. Gruppe5 (Lampeskift). Til fancoil hastighedskontrol;
*'-'-none, nothing is connected.
+
*'-'-ingen, intet er forbundet.
Example: out='LLB-G-V-W-'
+
Eksempel: out='LLB-G-V-W-'
 
|-
 
|-
|dm||char[4]||98||‘LLLL’||Each char is responsible for the type of a particular channel
+
|dm||char[4]||98||‘LLLL’||Hver char er ansvarlig for typen af en bestemt kanal
*‘g’ – use like halogen dimer-lamp
+
*'g' - brug som halogen dimer-lampe
*‘s’ – Soft Switch, lamp, when on/off power is supplied/deenergised smoothly (500msec)
+
*'s' – Soft Switch, lampe, når tænd/sluk strøm tilføres/afbrydes jævnt (500msec)
*‘k’ – Switch, lamp, when on/off power is supplied/deenergised immediately
+
*‘k’ – Afbryder, lampe, når tænd/sluk strøm tilføres/afbrydes med det samme
*‘l’ – LED Function, dimmable LED lamps
+
*'l' – LED-funktion, dæmpbare LED-lamper
*‘v’ linear Function of dimming
+
*'v' lineær Funktion af dæmpning
*‘-‘ – Channel disabled
+
*‘-‘ – Kanal deaktiveret
*‘+’ – Regular channel
+
*‘+’ – Almindelig kanal
Example: dm=’skl-‘
+
Eksempel: dm=’skl-‘
 
|-
 
|-
|def||integer 0-250||11-14||100||The default brightness level in case of a power reset (1..250). Example: def=250
+
|def||integer 0-250||11-14||100||Standard lysstyrkeniveau i tilfælde af en strømnulstilling (1..250). Eksempel: def=250
 
|-
 
|-
|min||integer 0-100||11-14||0||Minimum dimming level, example: min=10
+
|min||integer 0-100||11-14||0||Minimum dæmpningsniveau, eksempel: min=10
 
|-
 
|-
|max||integer 0-100||11-14||100||Maximum dimming level, example max=95
+
|max||integer 0-100||11-14||100||Maksimalt dæmpningsniveau, eksempel max=95
 
|-
 
|-
|start||integer 0-100||11-14||0||The Start function is used for lamps that lack the minimal voltage to get turned on. If the set value is lower than the start value, the lamp is turned on at the start value and them the light is dimmed down to the set level. Example: start=60
+
|start||integer 0-100||11-14||0||Start-funktionen bruges til lamper, der mangler den minimale spænding for at blive tændt. Hvis den indstillede værdi er lavere end startværdien, tændes lampen ved startværdien, og lyset dæmpes ned til det indstillede niveau. Eksempel: start=60
 
|-
 
|-
|force||integer 0-100||11-14||10||Time duration of the starting value (measured in milliseconds). Example: force=20
+
|force||integer 0-100||11-14||10||Tidsvarighed for startværdien (målt i millisekunder). Eksempel: force=20
 
|-
 
|-
|runtime||integer 0-60000||11-14||1000||Runtime is the speed of changing the brightness from ‘min’ to ‘max’ (measured in milliseconds). Example: runtime=1000
+
|runtime||integer 0-60000||11-14||1000||Runtime er hastigheden for at ændre lysstyrken fra 'min' til 'max' (målt i millisekunder). Eksempel: runtime=1000
 
|-
 
|-
|offset||integer (+/- 0…39)||39-46||'0'||sensor values offset; For example, offset is -3.8 :
+
|offset||integer (+/- 0…39)||39-46||'0'||sensorværdier offset; For eksempel er offset -3,8:
Example: hw="offset='-3.8'"
+
Eksempel: hw="offset='-3.8'"
 
|-
 
|-
|io||char[28]||98||io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'||Each char is responsible for the type of a particular channel
+
|io||char[28]||98||io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'||Hver char er ansvarlig for typen af en bestemt kanal
*'0' - led-dimmer
+
*'0' - LED-dæmper
*'1' - halogen-dimmer
+
*'1' - halogen-dæmper
*'2' - linear-dimmer
+
*'2' - lineær-dæmper
*'3'..'6' - RGB-3..6 channels
+
*'3'..'6' - RGB-3..6 kanaler
*'z' - WS2812B -string
+
*'z' - WS2812B -streng
    
*'e' - led-button inverse
 
*'e' - led-button inverse
editor, Interface administrators, Administrators, translation-admin, translator
9,706

edits