Changes

Created page with "*'e' - LED dugme inverzno *'d' - LED dugme *'c' - dugme obrnuto *'b' - dugme *'s' - prekidač *'k' - kontakt inverzan *'h' - kontakt *'l' - curenje *'n' - Neptun *'v' - inverz..."
Line 510: Line 510:  
*proverite integritet CAN vodova, napajanje napona na modulima.
 
*proverite integritet CAN vodova, napajanje napona na modulima.
   −
==HW Settings==
+
==HW Podešavanja==
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
!Name!!Type, range!!SUBID!!Default!!Description
+
!Ime!!Tip, opseg!!SUBID!!Podrazumevano!!Opis
 
|-
 
|-
|runtime||integer 0-100 || 1-10 || 15 ||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole);  
+
|runtime||integer 0-100 || 1-10 || 15 ||vreme rada je vreme otvaranja/zatvaranja u sekundama, koristi se za žaluziju, kapiju, ventil (2 pola);
<br>Example: runtime=15
+
<br>Primer: runtime=15
 
|-
 
|-
|runtimeopen||integer 0-60000||Blinds subId || ||Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000
+
|runtimeopen||integer 0-60000||Blinds subId || ||Runtimeopen je otvoreno vreme u milisekundama, koristi se za roletne; Primer: runtimeopen=15000
 
|-
 
|-
|runtimeclose||integer 0-60000||Blinds subId|| ||Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000
+
|runtimeclose||integer 0-60000||Blinds subId|| ||Runtimeclose je vreme zatvaranja u milisekundama, koristi se za roletne; Primer:runtimeclose=15000
 
|-
 
|-
|hold||integer 0-10000||1-10||500||hold is the bridging time in milliseconds, is used for gate and jalousie (by default hold is the same as runtime for jalousie and gate), lock; Example: hold=3500
+
|hold||integer 0-10000||1-10||500||zadržavanje je vreme premošćavanja u milisekundama, koristi se za kapiju i žaluziju (podrazumevano zadržavanje je isto kao vreme izvođenja za žaluziju i kapiju), zaključavanje; Primer: hold=3500
 
|-
 
|-
|def||string 'ON'||1-10||'OFF'||def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON'
+
|def||string 'ON'||1-10||'OFF'||def je status elementa postavljen nakon ponovnog pokretanja, koristi se za lampu, grejanje, ventil (1 pol); Primer: def='ON'
 
|-
 
|-
|stop||Char ‘R’||1-7||–||(for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is ‘r’ or ‘R’ then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., ‘d’ ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop=’r’
+
|stop||Char ‘R’||1-7||–||(za 2-polne kapije i roletne) Ako se deklariše tada komandom Stop tokom kretanja, pojavljuje se isti impuls kao i na početku kretanja. Pol, na kome se formiraju stop-impuli, definisan je parametrom Stop vrednost. Ako je 'r' ili 'R' onda se stop-impuls proizvodi na suprotnom od pola start-impulsa. Ako je bilo koja druga vrednost označena (npr. 'd'), onda je stop-impuls na istom polu. Ako je Runtime prošlo nakon početka kretanja, onda se stop-impuls ne formira. Primer: stop=’r’
 
|-
 
|-
|out||char[10]||98||'LLLLHHHHP-'||Each char is responsible for the type of a particular channel
+
|out||char[10]||98||'LLLLHHHHP-'||Svaki znak je odgovoran za tip određenog kanala
 
*'L'-Lamp;
 
*'L'-Lamp;
 
*'M'-Lamp Inverse;
 
*'M'-Lamp Inverse;
*'J'-Heating NO, valve-heating, normally open;
+
*'J'-grejanje NE, ventil za grejanje, normalno otvoren;
*'H'-Heating NC, valve-heating, normally closed;
+
*'H'-grejanje NC, ventil za grejanje, normalno zatvoren;
*'B'-Blinds (2 pole), jalousie/curtains;
+
*'B'-Roletne (2 pol), žaluzine/zavese;
*'C'-Blinds Inverse (2 pole), jalousie/curtains, invert open-close;
+
*'C'-Roletne Inverse (2 pol), žaluzije/zavese, invertno otvaranje-zatvaranje;
*'G'-Gate (2 pole), 2 pole gate;
+
*'G'-kapija (2-polna), 2-polna kapija;
*'D'-Gate (2 pole) Inverse, 2 pole gate, invert open-close;
+
*'D'-kapija (2-polna) Inverzna, 2-polna kapija, invertno otvaranje-zatvaranje;
*'X'-Gate (1 pole /short press), 1 pole gate;
+
*'Ks'-Gate (1 pole /kratki pritisak), 1 pole kapija;
*'Z'-Gate (1 pole) Inverse, 1 pole gate, invert open-close;
+
*'Z'-kapija (1 pol) Inverzna, 1-polna kapija, invertno otvaranje-zatvaranje;
*'V'-Valve (2 pole), 2 pole valve;
+
*'V'-ventil (2-polni), 2-polni ventil;
*'W'-Valve (2 pole) Inverse, 2 pole valve, invert open-close;
+
*'V'-ventil (2-polni) Inverzni, 2-polni ventil, invertno otvaranje-zatvaranje;
*'R'-Valve (1 pole), 1 pole valve,;
+
*'R'-ventil (1-polni), 1-polni ventil,;
*'S'-Valve (1 pole) Inverse, 1 pole valve, invert open-close;
+
*'S'-ventil (1 polni) Inverzni, 1-polni ventil, invertni otvaranje-zatvaranje;
*'K'-Lock (short press);
+
*'K'-Lock (kratak pritisak);
*'N'-Lock (short press) Inverse;
+
*'N'-Lock (kratak pritisak) Inverzno;
*'P'-Blinds (2 pole);
+
*'P'-roletne (2 polne);
*'O'-Blinds Inverse (2 pole), invert open-close;
+
*'O'-Blinds Inverse (2 pol), obrnuti otvaranje-zatvaranje;
*'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control;
+
*'F'-FanCoil. Group1 (Lamp Toggle). Za kontrolu brzine ventilatora;
*'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control;
+
*'E'-FanCoil. Group2 (Lamp Toggle). Za kontrolu brzine ventilatora;
*'Q'-FanCoil. Group3 (Lamp Toggle). For fancoil speed control;
+
*'K'-FanCoil. Group3 (Lamp Toggle). Za kontrolu brzine ventilatora;
*'U'-FanCoil. Group4 (Lamp Toggle). For fancoil speed control;
+
*'U'-FanCoil. Group4 (Lamp Toggle). Za kontrolu brzine ventilatora;
*'I'-FanCoil. Group5 (Lamp Toggle). For fancoil speed control;
+
*'I'-FanCoil. Grupa 5 (Prebacivanje lampe). Za kontrolu brzine ventilatora;
*'-'-none, nothing is connected.
+
*'-'-nema, ništa nije povezano.
Example: out='LLB-G-V-W-'
+
Primer: out='LLB-G-V-W-'
 
|-
 
|-
|dm||char[4]||98||‘LLLL’||Each char is responsible for the type of a particular channel
+
|dm||char[4]||98||‘LLLL’||Svaki znak je odgovoran za tip određenog kanala
*‘g’ – use like halogen dimer-lamp
+
*‘g’ – koristi se kao halogena dimer lampa
*‘s’ Soft Switch, lamp, when on/off power is supplied/deenergised smoothly (500msec)
+
*’s’ meki prekidač, lampa, kada se napajanje/isključenje nesmetano dovodi/isključuje (500 ms)
*‘k’ – Switch, lamp, when on/off power is supplied/deenergised immediately
+
*‘k’ – Prekidač, lampa, kada se napajanje uključi/isključi odmah
*‘l’ – LED Function, dimmable LED lamps
+
*‘l’ – LED funkcija, LED lampe koje se mogu prigušiti
*‘v’ – linear Function of dimming
+
*‘v’ – linearna funkcija zatamnjivanja
*‘-‘ – Channel disabled
+
*‘-‘ – Kanal je onemogućen
*‘+’ – Regular channel
+
*‘+’ – Redovan kanal
Example: dm=’skl-‘
+
Primer: dm=’skl-‘
 
|-
 
|-
|def||integer 0-250||11-14||100||The default brightness level in case of a power reset (1..250). Example: def=250
+
|def||integer 0-250||11-14||100||Podrazumevani nivo osvetljenosti u slučaju resetovanja napajanja (1..250). Primer: def=250
 
|-
 
|-
|min||integer 0-100||11-14||0||Minimum dimming level, example: min=10
+
|min||integer 0-100||11-14||0||Minimalni nivo zatamnjenja, primer: min=10
 
|-
 
|-
|max||integer 0-100||11-14||100||Maximum dimming level, example max=95
+
|max||integer 0-100||11-14||100||Maksimalni nivo zatamnjenja, primer max=95
 
|-
 
|-
|start||integer 0-100||11-14||0||The Start function is used for lamps that lack the minimal voltage to get turned on. If the set value is lower than the start value, the lamp is turned on at the start value and them the light is dimmed down to the set level. Example: start=60
+
|start||integer 0-100||11-14||0||Funkcija Start se koristi za lampe kojima nedostaje minimalni napon da bi se uključili. Ako je podešena vrednost niža od početne vrednosti, lampa se uključuje na početnoj vrednosti i njima se svetlo prigušuje do podešenog nivoa. Primer: start=60
 
|-
 
|-
|force||integer 0-100||11-14||10||Time duration of the starting value (measured in milliseconds). Example: force=20
+
|force||integer 0-100||11-14||10||Vremensko trajanje početne vrednosti (mereno u milisekundama). Primer: force=20
 
|-
 
|-
|runtime||integer 0-60000||11-14||1000||Runtime is the speed of changing the brightness from ‘min’ to ‘max’ (measured in milliseconds). Example: runtime=1000
+
|runtime||integer 0-60000||11-14||1000||Vreme rada je brzina promene svetline sa „min“ na „mak“ (mereno u milisekundama). Primer: runtime=1000
 
|-
 
|-
|offset||integer (+/- 0…39)||39-46||'0'||sensor values offset; For example, offset is -3.8 :
+
|offset||integer (+/- 0…39)||39-46||'0'||pomak vrednosti senzora; Na primer, ofset je -3,8:
Example: hw="offset='-3.8'"
+
Primer:hw="offset='-3.8'"
 
|-
 
|-
|io||char[28]||98||io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'||Each char is responsible for the type of a particular channel
+
|io||char[28]||98||io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'||Svaki znak je odgovoran za tip određenog kanala
*'0' - led-dimmer
+
*'0' - LED-dimer
*'1' - halogen-dimmer
+
*'1' - halogen-dimer
*'2' - linear-dimmer
+
*'2' - linearni dimmer
*'3'..'6' - RGB-3..6 channels
+
*'3'..'6' - RGB-3..6 kanali
*'z' - WS2812B -string
+
*'z' - VS2812B -string
   −
*'e' - led-button inverse
+
*'e' - LED dugme inverzno
*'d' - led-button
+
*'d' - LED dugme
*'c' - button inverse
+
*'c' - dugme obrnuto
*'b' - button
+
*'b' - dugme
*'s' - switch
+
*'s' - prekidač
*'k' - contact inverse
+
*'k' - kontakt inverzan
*'h' - contact
+
*'h' - kontakt
*'l' - leak
+
*'l' - curenje
 
*'n' - Neptun
 
*'n' - Neptun
*'v' - motion inverse
+
*'v' - inverzno kretanje
*'m' - motion
+
*'m' - pokret
*'r' - thermo-resistor
+
*'r' - termo-otpornik
 
*'t' - DALLAS
 
*'t' - DALLAS
*'-' - none
+
*'-' - nijedan
Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
+
Primer: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
 
|-
 
|-
|hw||string||98||-||hw="...", where
+
|hw||string||98||-||hw="...", gde
*pwm_invert PWM inverting [1, 0];
+
*pvm_invert PVM invertovanje [1, 0];
*lbn_bright – brightness of led buttons, range (0 - 255);
+
*lbn_bright – osvetljenost LED tastera, opseg (0 - 255);
*f – by default PWM frequency is 1000, range (1 - 5000).
+
*f – podrazumevano je PVM frekvencija 1000, opseg (1 - 5000).
Example:
+
Primer:
 
<syntaxhighlight lang="xml" line>
 
<syntaxhighlight lang="xml" line>
 
hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
 
hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
 
</syntaxhighlight>
 
</syntaxhighlight>
 
|-
 
|-
|colspan="3"|'''Only for Metaforsa 3.plus'''
+
|colspan="3"|'''Samo za Metaforsa 3.plus'''
 
|-
 
|-
|cfg||string||98||9600/8N1||cfg='SPEED/BPS', where
+
|cfg||string||98||9600/8N1||cfg='SPEED/BPS', gde
*SPEED – baud rate [1200..115200];
+
*SPEED – brzina prenosa [1200..115200];
*B – data length [7,8];
+
*B – dužina podataka [7,8];
*P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
+
*P – prisustvo i tip bita parnosti [N(bez parnosti),E(parni paritet),O(neparni paritet)];
*S – stop bit length [1, 1.5 or 2].
+
*S – dužina stop bita [1, 1,5 ili 2].
Example:
+
Primer:
 
<syntaxhighlight lang="xml" line>
 
<syntaxhighlight lang="xml" line>
 
hw="cfg='9600/8N1'"
 
hw="cfg='9600/8N1'"
 
</syntaxhighlight>
 
</syntaxhighlight>
 
|-
 
|-
|[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following
+
|[Protocol]||string||98||—||Podešavanje protokola je opisano parametrom protokola. Sledeće
protocols are supported:
+
protokoli su podržani:
*'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added;
+
*'modbus', Modbus protokol, na kraju preusmeravanja se dodaje kontrolni zbir CRC16(Modbus);
*'dmx', DMX protocol;
+
*'dmk', DMKS protokol;
*'CO2' for connecting Larnitech CO2 sensors;
+
*'CO2' za povezivanje Larnitech CO2 senzora;
*'salda' for connecting Salda ventilation.
+
*'salda' za povezivanje Salda ventilacije.
Example:
+
Primer:
 
<syntaxhighlight lang="xml" line>
 
<syntaxhighlight lang="xml" line>
 
hw="cfg='9600/8N1' modbus"
 
hw="cfg='9600/8N1' modbus"
 
</syntaxhighlight>
 
</syntaxhighlight>
 
|-
 
|-
|echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module
+
|echo||on; off||98||'off'||Za proveru podešavanja i testiranje eho parametar se može koristiti. Modul
echo-reply can be turned on or off with the help of this parameter.Echo parameter value:
+
echo-repli se može uključiti ili isključiti uz pomoć ovog parametra. Vrednost parametra Echo:
*'off'
+
*'van'
*'on'
+
*'na'
Example:
+
Primer:
 
<syntaxhighlight lang="xml" line>
 
<syntaxhighlight lang="xml" line>
 
hw="cfg='9600/8N1' echo='off'"
 
hw="cfg='9600/8N1' echo='off'"
editor, Interface administrators, Administrators, translation-admin, translator
9,706

edits