6 bytes added ,  15:25, 21 December 2021
Line 149: Line 149:  
|Number of discrete inputs || 24
 
|Number of discrete inputs || 24
 
|-  
 
|-  
|Number of digital inputs || 4  
+
|Number of digital inputs || 4 (up to 8 FW-TS sensors)
 
|-
 
|-
 
|Current maximum rating on the direct-current voltage connectors || 50mA  
 
|Current maximum rating on the direct-current voltage connectors || 50mA  
Line 290: Line 290:  
{| class="wikitable" style="width:800px";
 
{| class="wikitable" style="width:800px";
 
|-
 
|-
|[[File:lamps.png|350px|lamp]]<br>'''Fig. 4'''|| style="margin:20px"|Such actuators as light, electric contactor, heating thermal actuator should be switched on any of the outputs 1 – 10, the neutral wire and the ground wire should be connected directly to the switchboard. The example of connection is shown in '''Fig.4'''.
+
|[[File:lamps.png|350px|lamp]]<br>'''Fig. 4'''|| style="margin:20px"|Such actuators as light, electric contactor, heating thermal actuator should be switched on any of the outputs 1 – 12, the neutral wire and the ground wire should be connected directly to the switchboard. The example of connection is shown in '''Fig.4'''.
 
|}
 
|}
  −
      
====Connection of high load device====
 
====Connection of high load device====
Line 313: Line 311:  
|colspan="2" style="background-color:#dededf" |'''Caution: Before applying power to the load, make sure that the output configuration of METAFORSA module is correct. The incorrect configuration or incorrect connection can cause the module failure and/or failure of the equipment connected to it, and even a fire.'''
 
|colspan="2" style="background-color:#dededf" |'''Caution: Before applying power to the load, make sure that the output configuration of METAFORSA module is correct. The incorrect configuration or incorrect connection can cause the module failure and/or failure of the equipment connected to it, and even a fire.'''
 
|-
 
|-
|[[File:1pvalve.png|350px|valve]]<br>'''Fig. 5'''|| style="margin:20px"|The single pole water/gas supply valve is connected to any of the outputs of 1 – 10, the (neutral wire and the ground wire are connected directly to the switchboard. The example of connection is shown in '''Fig.5'''.
+
|[[File:1pvalve.png|350px|valve]]<br>'''Fig. 5'''|| style="margin:20px"|The single pole water/gas supply valve is connected to any of the outputs of 1 – 12, the (neutral wire and the ground wire are connected directly to the switchboard. The example of connection is shown in '''Fig.5'''.
 
|}
 
|}
  −
      
====Connection of double-pole water/gas supply valve====
 
====Connection of double-pole water/gas supply valve====
Line 430: Line 426:  
#Install the module in the switchboard on the DIN-rail and fix it with the special latch on the module base.
 
#Install the module in the switchboard on the DIN-rail and fix it with the special latch on the module base.
 
#Fasten the supply unit on the left side of the module.
 
#Fasten the supply unit on the left side of the module.
#Connect the connector (4) having the noise filter pre-installed which is supplied complete with the module.
+
#Connect the connector (3) having the noise filter pre-installed which is supplied complete with the module.
#Connect the connectors (5), (6).
+
#Connect the connectors (4-7).
#Connect the connectors (1), (2).
+
#Connect the connectors (1).
#Connect the connector (3).
+
#Connect the connector (2).
 
#Apply power to the supply unit of METAFORSA module.
 
#Apply power to the supply unit of METAFORSA module.
 
#Wait until the module is loaded, then configure it in accordance with the '''System Setup Instructions.'''
 
#Wait until the module is loaded, then configure it in accordance with the '''System Setup Instructions.'''
#Apply power to the connectors (1), (2).
+
#Apply power to the connectors (1).
 
#Check all equipment for proper operation.
 
#Check all equipment for proper operation.
  