Contents
BUILT-IN FLOOR LEAKAGE SENSOR
Water leakage sensor with an alarm light, mountable in the floor
surface. Used together with DW-WL02 or BW-LSA modules.
Pin assignments
Example of connection
Module parameters
Parameter name | Value |
---|---|
Power supply | 9-12 V DC |
Max current | 20 mA |
Compatible with | MF-10 DW-WL02/HTxx BW-LSA |
Mounting | Built into the floor |
Case material | stainless steel |
Protection | IP65 |
Temperature range | -10 … +50 °C |
Size | 18x18x20 mm |
Weight | 20 g |
HW settings
Name | Type, range | SUBID | Default | Description |
---|---|---|---|---|
c0 | int[4] | sensors subId | 0;0;255;15 |
Normal state color in format ‘red;green;blue;blink’ red, green, blue – 0..255; blink:
Example: c0='150;150;255;0' |
c1 | int[4] | sensors subId | 0;0;255;15 |
On-start color in format ‘red;green;blue;blink’ red, green, blue – 0..255; blink:
Example: c1='150;150;255;0' |
c2 | int[4] | sensors subId | 255;100;0;15 |
‘Leak was previously reported’ color in format ‘red;green;blue;blink’ red, green, blue – 0..255; blink:
Example: c2='150;150;255;0' |
c3 | int[4] | sensors subId | 255;0;0;15 |
On-leak color in format ‘red;green;blue;blink’ red, green, blue – 0..255; blink:
Example: c3='150;150;255;0' |
sens | int | sensors subId | 128 |
Sensor sensitivity Example: sens='180' |
* Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly.