MAIN GATEWAY
It is used for accumulation and storage of system data. The device determines the logical scheme of the system and allows authorized access to the system via the Internet. It also converts Ethernet into CAN bus and vice versa. DE-MG has a built-in IR receiver.The DE-MG can be controlled via cloud with a securely encrypted signal. The system history from all other devices and sensors is stored on the DE-MG for one year. Its plug and play feature means that it automatically detects and configures new Larnitech devices that are added to the system. A large and constantly updated database of ready-made scripts ensures that your home does everything your heart may desire. Get things going by telling your home what to do with the help of Siri, Alexa or Google Home. Get push notifications on your phone whenever the system has things to tell you and enjoy the ultimate control at your fingertips
Features
One DE-MG can manage up to 1000 devices
Cloud connection and control of all house systems
2xCAN, EIB, Bluetooth interfaces
4-core processor
Voice control (Siri, Alexa, Google Home)
Plugins engine allows expanding the system possibilities (e.g. integrating with Satel, Philips Hue, IKEA lights)
Safety against unauthorized intrusion ensured with RSA/AES256 encryption
Push notifications from the system on your phone (also possible to receive through Telegram and Viber messengers)
History (meter data for 1 year is stored)
Plug and play (possibility for fast and user-friendly extension of the system)
Regular system updates
Large constantly updated database of scripts to meet all your needs
Automatic daily backups via cloud with the possibility to restore the initial configuration
Open API (which allows integrating Larnitech into other systems)
Interactive and user-friendly LT SETUP Web interface available for advanced configuration
The module supplies power to CAN bus, ensuring system reliability and stable operation
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.To avoid the risk of fire, electric shock, damage to the system and/or personal injury, the system installation and assembly must be performed in accordance with the instructions listed below:
all connectivity work must be carried out with the power turned OFF;
use appropriate tools and personal protection against electric shock;
do not use damaged cables, wires and connectors;
avoid folding the cables and wires;
do not apply excessive force to the wires by kinking or pressing them too hard: the inner conductors of the cables and wires may get stripped or damaged;
do not use the power socket with poor contacts to connect;
do not exceed the load limit parameters specified in the manual;
the supply conductors wire section is subject to the specifications for current density limit, insulation type and wire material. Light section can result in cable overheating and fire.
When the power is on, NEVER:
connect/disconnect the connectors;
open modules and sensors.
Module view
Indicators
IR Reсiever
Recovery button
Power supply
CAN1
CAN2
Ethernet
EiB
Сonnection example
Module parameters
Parameter name
Value
Type of connection
CAN, Ethernet
Input/output interfaces
Ethernet, 2xCAN, EIB, Bluetooth
Data speed
10/100Mb/s
Max CAN deviсes
100(50 per CAN)
CAN bus topology
BUS
Number of CAN ports
2
Power supply
11.5 … 27.5 V DC
24V, 2.5A Recommended
Max own current (24V)
140mA
Max CAN bus length
800 m* (twisted pair 5 cat)
Max current per CAN bus
700mA
IR Receiver angle
30°
Case material
ABS
Protection
IP40
Equipment installation type
DIN-rail (EN 60715)
Temperature range
-10 … +50°C
Size
6U, 104x90x58 mm
Weight
145 g
* – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors
Indication of module operation.