Changes
Jump to navigation
Jump to search
764 bytes added
, 13:50, 17 August 2021
{{RevisionChanger | hasA = 1 | hasB = 1}}
{{Infobox module
| name = EW-WL.A
| image = EW-WLB.jpg
| voltage = 9-12 V DC
| dim = 18x18x20 mm
}}
==BUILT-IN FLOOR LEAKAGE SENSOR==
Water leakage sensor with an alarm light, mountable in the floor
surface. Used together with DW-WL02 or BW-LSA modules.
==Pin assignment==
[[File:EWWLB PIN.jpg|300px]]
==Example of connection==
[[File:EWWLB EXA.jpg|400px]]
==Module parameters==
{{ Mp
| power = 9-12 V DC
| maxcur24v = 20 mA
| compatible = MF-10<br><br>DW-WL02/HTxx<br>BW-LSA
| instalation = Built into the floor
| case = stainless steel
| protection = IP65
| temprange = -10 … +50 °C
| size = 18x18x20 mm
| weight = 20g
}}