{{Infobox module
 
| name      = MF-14
 
| name      = MF-14
Line 21: Line 22:  
While working with the system, you must strictly comply with all the requirements set out in this manual. Failure to comply may result in damage to the device, its failure, electric shock, fire and other fallout.
 
While working with the system, you must strictly comply with all the requirements set out in this manual. Failure to comply may result in damage to the device, its failure, electric shock, fire and other fallout.
 
The manufacturer reserves the right to make changes to this manual without prior notice. This manual is an integral part of the system and shall remain with the end-use customer.
 
The manufacturer reserves the right to make changes to this manual without prior notice. This manual is an integral part of the system and shall remain with the end-use customer.
 +
 +
‎<youtube>IC_-C7zVTPc</youtube>
    
==Features==
 
==Features==
Line 168: Line 171:  
|-
 
|-
 
| Dimmer type || MOSFET  
 
| Dimmer type || MOSFET  
 +
|-
 +
| Dimmer load type || R,C
 
|-
 
|-
 
| Dimming type || trailing edge  
 
| Dimming type || trailing edge  
Line 191: Line 196:  
|Permissible humidity || 0 … 95% (non-condensing)  
 
|Permissible humidity || 0 … 95% (non-condensing)  
 
|-
 
|-
|Power supply || 23 … 27.5 V DC<br>24V, 0.75A Recommended
+
|Power supply || 12 … 27.5 V DC<br>24V, 0.75A Recommended
 
|-
 
|-
 
|Maximum demand || 0.5А  
 
|Maximum demand || 0.5А  
Line 237: Line 242:  
{| class="wikitable" style="clear:left;"
 
{| class="wikitable" style="clear:left;"
 
|-
 
|-
|1 || — connector for load application and power supply
+
|1 || — connector for load application
 
|-
 
|-
 
|2 || — connector for dimming-lamps application
 
|2 || — connector for dimming-lamps application
Line 291: Line 296:  
|[[File:OW.png|80px|frameless]] ||OneWire|| Digital sensors connection (temperature)<br>VCC — sensors power supply output +5V<br>OW1-OW4 — OneWire data buses<br>GND — common
 
|[[File:OW.png|80px|frameless]] ||OneWire|| Digital sensors connection (temperature)<br>VCC — sensors power supply output +5V<br>OW1-OW4 — OneWire data buses<br>GND — common
 
|-
 
|-
|[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| External modules connection for CAN-bus<br>VСС — 12V output for external devices power supply<br>GND — common<br>L — CAN-L data bus<br>H — CAN-H data bus
+
|[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| External modules connection for CAN-bus<br>VСС — 24V output for external devices power supply<br>GND — common<br>L — CAN-L data bus<br>H — CAN-H data bus
 
|}
 
|}
    
{{indicationmfold}}
 
{{indicationmfold}}
   −
 
+
===System installation and assembly===
===System installation and assembly===  
   
Before connecting the system, you must:
 
Before connecting the system, you must:
   Line 431: Line 435:  
====Connection of buttons/switches/magnetic reed switches====
 
====Connection of buttons/switches/magnetic reed switches====
   −
Buttons and reed switches are connected to any free input in1-in16, while their second contact point is connected to GND point of the relevant METAFORSA module group, + 12V power outputs – not in use. The example of connection is shown in '''Fig. 14-16'''.
+
Buttons and reed switches are connected to any free input in1-in24, while their second contact point is connected to GND point of the relevant METAFORSA module group, + 12V power outputs – not in use. The example of connection is shown in '''Fig. 14-15'''.
 
{| style="width"700px"
 
{| style="width"700px"
 
|- style="tezt-align:center;"
 
|- style="tezt-align:center;"
 
|[[File:Buttons.png|300px|center]]<br>'''Fig14''' connection of buttons/switching units || [[File:Reed-sv.png|300px|center]]<br>'''Fig15''' connection of the magnetic reed switches (window/door position sensors)
 
|[[File:Buttons.png|300px|center]]<br>'''Fig14''' connection of buttons/switching units || [[File:Reed-sv.png|300px|center]]<br>'''Fig15''' connection of the magnetic reed switches (window/door position sensors)
 
|}
 
|}
      
====Connection of digital sensors====
 
====Connection of digital sensors====
Line 612: Line 615:  
Example: in='MMMMMMMMMMMMLLLLLLLLLLLL'
 
Example: in='MMMMMMMMMMMMLLLLLLLLLLLL'
 
12 motion sensors and 12 leak-sensors;
 
12 motion sensors and 12 leak-sensors;
in='BBBBBBBBSSSSSSRRRRSSRRRR'
+
in='BBBBBBBBSSSSSSBBBBSSSSSS'
8 buttons; 8 switches and 8 LED channels.
+
12 buttons; 12 switches.
 
|}
 
|}
  