Changes
Jump to navigation
Jump to search
67 bytes removed
, 13 March
Line 477: |
Line 477: |
| ===Postopek izklopa in odstranitve modula METAFORSA=== | | ===Postopek izklopa in odstranitve modula METAFORSA=== |
| | | |
− | #De-energize the module by disconnecting the circuit breaker assembly of the load power supply and METAFORSA module supply unit. Verify the voltage is absent on the terminals (1), (2) of the connector wires and on the input terminals of the supply unit. | + | #Modul izklopite tako, da odklopite sklop odklopnika napajalnika bremena in napajalne enote modula METAFORSA. Preverite, ali na sponkah (1), (2) priključnih žic in na vhodnih sponkah napajalne enote ni napetosti. |
− | #Disconnect the load power supply connectors (1), (2). | + | #Odklopite priključke za napajanje bremena (1), (2). |
− | #Disconnect the connector (3). | + | #Odklopite konektor (3). |
− | #Disconnect the connectors (4)-(6). | + | #Odklopite konektorje (4)-(6). |
− | #Remove the module from the DIN-rail, releasing the latch at the bottom of the module base. | + | #Odstranite modul z DIN-tirnice in sprostite zapah na dnu podnožja modula. |
| | | |
| ==Hardware setup== | | ==Hardware setup== |