Line 1: |
Line 1: |
| <languages/> | | <languages/> |
| <translate> | | <translate> |
| + | <!--T:1--> |
| {{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}} | | {{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}} |
| {{Infobox module | | {{Infobox module |
Line 16: |
Line 17: |
| }} | | }} |
| | | |
− | ==5-CHANNEL EXTENSION MODULE== | + | ==5-CHANNEL EXTENSION MODULE== <!--T:2--> |
| Has 5 outputs for connecting loads and 12 inputs for connecting | | Has 5 outputs for connecting loads and 12 inputs for connecting |
| various sensors/buttons. | | various sensors/buttons. |
| | | |
− | ==Features== | + | ==Features== <!--T:3--> |
| | | |
| + | <!--T:4--> |
| *5 universal outputs support: | | *5 universal outputs support: |
| **Lights | | **Lights |
Line 37: |
Line 39: |
| **Motion detectors | | **Motion detectors |
| | | |
| + | <!--T:5--> |
| <div class="caution"> | | <div class="caution"> |
| CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. | | CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. |
Line 53: |
Line 56: |
| </div> | | </div> |
| | | |
− | ==Overview== | + | ==Overview== <!--T:6--> |
| [[File:HT05B VIEW.png|500px]] | | [[File:HT05B VIEW.png|500px]] |
| | | |
− | ==Example of connection== | + | ==Example of connection== <!--T:7--> |
| [[File:HT05B EXA.png|500px]] | | [[File:HT05B EXA.png|500px]] |
| | | |
− | ==Module dimensions== | + | ==Module dimensions== <!--T:8--> |
| [[File:HT05B DIMM.png|500px]] | | [[File:HT05B DIMM.png|500px]] |
| | | |
− | ==Module parameters== | + | ==Module parameters== <!--T:9--> |
| | | |
| + | <!--T:10--> |
| {{ Mp | | {{ Mp |
| | outqty = 5 | | | outqty = 5 |
Line 81: |
Line 85: |
| }} | | }} |
| | | |
− | ==Connectivity recommendations== | + | ==Connectivity recommendations== <!--T:11--> |
| | | |
| + | <!--T:12--> |
| In order to protect the actuator and loads connected to it, installing a circuit breaker is recommended. | | In order to protect the actuator and loads connected to it, installing a circuit breaker is recommended. |
| The nominal value of the circuit breaker should be calculated based on the maximum total load of connected | | The nominal value of the circuit breaker should be calculated based on the maximum total load of connected |
Line 90: |
Line 95: |
| for each load. | | for each load. |
| | | |
− | ==Connection of actuators== | + | ==Connection of actuators== <!--T:13--> |
| | | |
| + | <!--T:14--> |
| <div class="caution"> Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire. | | <div class="caution"> Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire. |
| If free (unused) channels remain in a given group after a curtain/jalousie/shutter actuator with low-voltage control or gate actuator has been connected to it, these channels need to be left unused. (Do not connect other devices to them!) </div> | | If free (unused) channels remain in a given group after a curtain/jalousie/shutter actuator with low-voltage control or gate actuator has been connected to it, these channels need to be left unused. (Do not connect other devices to them!) </div> |
| | | |
− | ===Connection of the lights/electric contactor/heating thermal actuator=== | + | ===Connection of the lights/electric contactor/heating thermal actuator=== <!--T:15--> |
| | | |
| + | <!--T:16--> |
| [[File:lamps.png|200px]]<br> | | [[File:lamps.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
Line 104: |
Line 111: |
| | | |
| | | |
− | ===Connection of high load device=== | + | ===Connection of high load device=== <!--T:17--> |
| | | |
| + | <!--T:18--> |
| {| class="wikitable" style="width:800px"; | | {| class="wikitable" style="width:800px"; |
| |- | | |- |
Line 114: |
Line 122: |
| |} | | |} |
| | | |
− | ===Connection of curtain/jalousie/shutter actuator with 220V force control=== | + | ===Connection of curtain/jalousie/shutter actuator with 220V force control=== <!--T:19--> |
| | | |
| + | <!--T:20--> |
| [[File:Pjalousie.png|200px]]<br> | | [[File:Pjalousie.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
Line 122: |
Line 131: |
| </syntaxhighlight> | | </syntaxhighlight> |
| | | |
− | ===Connection of curtain/jalousie/shutter actuator with low-voltage control=== | + | ===Connection of curtain/jalousie/shutter actuator with low-voltage control=== <!--T:21--> |
| | | |
| + | <!--T:22--> |
| [[File:Ljalousie.png|200px]]<br> | | [[File:Ljalousie.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
Line 130: |
Line 140: |
| </syntaxhighlight> | | </syntaxhighlight> |
| | | |
− | ===Connection of single-pole gate actuator=== | + | ===Connection of single-pole gate actuator=== <!--T:23--> |
| | | |
| + | <!--T:24--> |
| [[File:1pgate.png|200px]]<br> | | [[File:1pgate.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
Line 138: |
Line 149: |
| </syntaxhighlight> | | </syntaxhighlight> |
| | | |
− | ===Connection of double-pole gate actuator=== | + | ===Connection of double-pole gate actuator=== <!--T:25--> |
| | | |
| + | <!--T:26--> |
| [[File:2pgate.png|200px]]<br> | | [[File:2pgate.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
Line 148: |
Line 160: |
| | | |
| | | |
− | ===Connection of single-pole water/gas supply valve=== | + | ===Connection of single-pole water/gas supply valve=== <!--T:27--> |
| | | |
| + | <!--T:28--> |
| [[File:1pvalve.png|200px]]<br> | | [[File:1pvalve.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
Line 156: |
Line 169: |
| </syntaxhighlight> | | </syntaxhighlight> |
| | | |
− | ===Connection of double-pole water/gas supply valve=== | + | ===Connection of double-pole water/gas supply valve=== <!--T:29--> |
| | | |
| + | <!--T:30--> |
| [[File:2pvalve.png|200px]]<br> | | [[File:2pvalve.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
Line 164: |
Line 178: |
| </syntaxhighlight> | | </syntaxhighlight> |
| | | |
− | ===Connection of fancoil control unit=== | + | ===Connection of fancoil control unit=== <!--T:31--> |
| | | |
| + | <!--T:32--> |
| [[File:fancoil.png|200px]]<br> | | [[File:fancoil.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
Line 173: |
Line 188: |
| | | |
| | | |
− | ==Indication of module operation== | + | ==Indication of module operation== <!--T:33--> |
| | | |
| + | <!--T:34--> |
| {{Indicationold}} | | {{Indicationold}} |
| | | |
− | ==Module installation and connection procedure== | + | ==Module installation and connection procedure== <!--T:35--> |
| | | |
| + | <!--T:36--> |
| #Connect the outputs. | | #Connect the outputs. |
| #Connect the inputs. | | #Connect the inputs. |
Line 186: |
Line 203: |
| #Check all equipment for proper operation. | | #Check all equipment for proper operation. |
| | | |
− | ==Module shut-off and deinstallation procedure== | + | ==Module shut-off and deinstallation procedure== <!--T:37--> |
| | | |
| + | <!--T:38--> |
| #Disconnect the power from the load | | #Disconnect the power from the load |
| #Disconnect the CAN connector. | | #Disconnect the CAN connector. |
Line 193: |
Line 211: |
| #Disconnect the outputs. | | #Disconnect the outputs. |
| | | |
− | ==HW Settings== | + | ==HW Settings== <!--T:39--> |
| | | |
| + | <!--T:40--> |
| {| class="wikitable" | | {| class="wikitable" |
| |- | | |- |
Line 252: |
Line 271: |
| |} | | |} |
| | | |
| + | <!--T:41--> |
| <syntaxhighlight lang="xml" line> | | <syntaxhighlight lang="xml" line> |
| <item addr="331:1" auto-period="600" cfgid="41" name="Lamp" type="lamp" hw="def='ON'" uniq_id="189"/> | | <item addr="331:1" auto-period="600" cfgid="41" name="Lamp" type="lamp" hw="def='ON'" uniq_id="189"/> |