Changes

Jump to navigation Jump to search
495 bytes added ,  14:05, 1 January 2022
Marked this version for translation
Line 1: Line 1:  
<languages/>
 
<languages/>
 
<translate>
 
<translate>
 +
<!--T:1-->
 
{{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}}
 
{{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}}
 
{{Infobox module
 
{{Infobox module
Line 16: Line 17:  
}}
 
}}
   −
==10-CHANNEL ACTUATOR==
+
==10-CHANNEL ACTUATOR== <!--T:2-->
    +
<!--T:3-->
 
This module is designed for high power AC/DC circuits commutation.
 
This module is designed for high power AC/DC circuits commutation.
 
Applicable for light, power sockets, for control of fan coil units, locks, blinds/gates.
 
Applicable for light, power sockets, for control of fan coil units, locks, blinds/gates.
   −
==Features==
+
==Features== <!--T:4-->
 
*Control of a wide range of devices:
 
*Control of a wide range of devices:
 
**Lights
 
**Lights
Line 36: Line 38:  
*Regular software updates
 
*Regular software updates
    +
<!--T:5-->
 
<div class="caution">
 
<div class="caution">
 
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
 
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
Line 52: Line 55:  
</div>
 
</div>
   −
==Overview==
+
==Overview== <!--T:6-->
    +
<!--T:7-->
 
[[File:LC10C VIEW.png|500px]]
 
[[File:LC10C VIEW.png|500px]]
   −
==Example of connection==
+
==Example of connection== <!--T:8-->
    +
<!--T:9-->
 
[[File:LC10C EXA.png|500px]]
 
[[File:LC10C EXA.png|500px]]
   −
==Module dimensions==
+
==Module dimensions== <!--T:10-->
    +
<!--T:11-->
 
[[File:LC10C DIMM.png|500px]]
 
[[File:LC10C DIMM.png|500px]]
   −
==Module parameters==
+
==Module parameters== <!--T:12-->
    +
<!--T:13-->
 
{{ Mp
 
{{ Mp
 
| outqty          = 10
 
| outqty          = 10
Line 85: Line 92:  
}}
 
}}
   −
==Connectivity recommendations==
+
==Connectivity recommendations== <!--T:14-->
    +
<!--T:15-->
 
In order to protect the actuator and loads connected to it, installing a circuit breaker is recommended.
 
In order to protect the actuator and loads connected to it, installing a circuit breaker is recommended.
 
The nominal value of the circuit breaker should be calculated based on the maximum total load of connected
 
The nominal value of the circuit breaker should be calculated based on the maximum total load of connected
Line 94: Line 102:  
for each load.
 
for each load.
   −
==Connection of actuators==
+
==Connection of actuators== <!--T:16-->
    +
<!--T:17-->
 
<div class="caution"> Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.
 
<div class="caution"> Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.
 
If free (unused) channels remain in a given group after a curtain/jalousie/shutter actuator with low-voltage control or gate actuator has been connected to it, these channels need to be left unused. (Do not connect other devices to them!) </div>
 
If free (unused) channels remain in a given group after a curtain/jalousie/shutter actuator with low-voltage control or gate actuator has been connected to it, these channels need to be left unused. (Do not connect other devices to them!) </div>
   −
===Connection of the lights/electric contactor/heating thermal actuator===
+
===Connection of the lights/electric contactor/heating thermal actuator=== <!--T:18-->
    +
<!--T:19-->
 
[[File:lamps.png|200px]]<br>
 
[[File:lamps.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 107: Line 117:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Connection of high load device===
+
===Connection of high load device=== <!--T:20-->
    +
<!--T:21-->
 
{| class="wikitable" style="width:800px";
 
{| class="wikitable" style="width:800px";
 
|-
 
|-
Line 117: Line 128:  
|}
 
|}
   −
===Connection of curtain/jalousie/shutter actuator with 220V force control===
+
===Connection of curtain/jalousie/shutter actuator with 220V force control=== <!--T:22-->
    +
<!--T:23-->
 
[[File:Pjalousie.png|200px]]<br>
 
[[File:Pjalousie.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 125: Line 137:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Connection of curtain/jalousie/shutter actuator with low-voltage control===
+
===Connection of curtain/jalousie/shutter actuator with low-voltage control=== <!--T:24-->
    +
<!--T:25-->
 
[[File:Ljalousie.png|200px]]<br>
 
[[File:Ljalousie.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 133: Line 146:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Connection of single-pole gate actuator===
+
===Connection of single-pole gate actuator=== <!--T:26-->
    +
<!--T:27-->
 
[[File:1pgate.png|200px]]<br>
 
[[File:1pgate.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 141: Line 155:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Connection of double-pole gate actuator===
+
===Connection of double-pole gate actuator=== <!--T:28-->
    +
<!--T:29-->
 
[[File:2pgate.png|200px]]<br>
 
[[File:2pgate.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 149: Line 164:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Connection of single-pole water/gas supply valve===
+
===Connection of single-pole water/gas supply valve=== <!--T:30-->
    +
<!--T:31-->
 
[[File:1pvalve.png|200px]]<br>
 
[[File:1pvalve.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 157: Line 173:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Connection of double-pole water/gas supply valve===
+
===Connection of double-pole water/gas supply valve=== <!--T:32-->
    +
<!--T:33-->
 
[[File:2pvalve.png|200px]]<br>
 
[[File:2pvalve.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 165: Line 182:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
===Connection of fancoil control unit===
+
===Connection of fancoil control unit=== <!--T:34-->
    +
<!--T:35-->
 
[[File:fancoil.png|200px]]<br>
 
[[File:fancoil.png|200px]]<br>
 
Sample HW for this configuration
 
Sample HW for this configuration
Line 173: Line 191:  
</syntaxhighlight>
 
</syntaxhighlight>
   −
==Indication of module operation==
+
==Indication of module operation== <!--T:36-->
 
===Bootloader===
 
===Bootloader===
 
{{indication| textBBB= Waiting for bootloader command}}
 
{{indication| textBBB= Waiting for bootloader command}}
Line 184: Line 202:  
}}
 
}}
   −
==Module installation and connection procedure==
+
==Module installation and connection procedure== <!--T:37-->
    +
<!--T:38-->
 
*Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base.
 
*Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base.
 
*Connect the CAN connector.
 
*Connect the CAN connector.
Line 193: Line 212:  
*Check all equipment for proper operation.
 
*Check all equipment for proper operation.
   −
==Module shut-off and deinstallation procedure==
+
==Module shut-off and deinstallation procedure== <!--T:39-->
    +
<!--T:40-->
 
*Disconnect the power from the load.
 
*Disconnect the power from the load.
 
*Disconnect the channels (1-10).
 
*Disconnect the channels (1-10).
Line 200: Line 220:  
*Remove the module from the DIN rail, releasing the latch at the bottom of the module base.
 
*Remove the module from the DIN rail, releasing the latch at the bottom of the module base.
   −
==HW settings==
+
==HW settings== <!--T:41-->
 
{|class="wikitable"
 
{|class="wikitable"
 
|-
 
|-
Line 245: Line 265:  
|}
 
|}
    +
<!--T:42-->
 
<syntaxhighlight lang="xml" line>
 
<syntaxhighlight lang="xml" line>
 
<item addr="300:1" cfgid="98" hw="runtime=60" name="Jalousie" sub-type="120" type="jalousie" uniq_id="117"/>
 
<item addr="300:1" cfgid="98" hw="runtime=60" name="Jalousie" sub-type="120" type="jalousie" uniq_id="117"/>
editor, translation-admin, translator
4,754

edits

Navigation menu