Changes

Jump to navigation Jump to search
5,787 bytes added ,  14:44, 21 July 2021
no edit summary
Line 282: Line 282:     
{{indicationmf10}}
 
{{indicationmf10}}
 +
 +
===System installation and assembly===
 +
Before connecting the system, you must:
 +
 +
 +
*site the sensor and actuators (if not pre-installed), set the sensors and actuators;
 +
*site the module and power supply.
 +
 +
 +
'''Note: The module must be installed near the power supply voltage source.'''
 +
 +
 +
<div class="caution">CAUTION!
 +
#'''AC power voltage must be provided to the system input through the circuit breaker assembly. It should be installed close to the power supply.'''
 +
#'''The load is applied through the circuit breaker assembly. It can be both common – for all groups, and individual – for each  group (fig. 3,4).'''
 +
</div>
 +
<div style="clear: both">[[File:mf10exa1.jpg|700px|Fig. 3]]</div>
 +
<br>'''Fig 3.'''
 +
<div style="clear: both">[[File:mf10exa2.jpg|700px|Fig. 4]]</div>
 +
<br>'''Fig 4.'''<br>
 +
 +
'''Notes:'''
 +
 +
#'''The power of circuit breaker assembly must comply with the load capacity;'''
 +
#'''Nothing else than the phase conductors can be connected to the module, the neutral wire is connected separately.'''
 +
 +
Typical diagram of METAFORSA MF-10.A module connection is shown in '''fig. 5.'''
 +
<div style="clear: both">[[File:mf10exa3.jpg|700px|Fig. 4]]</div>
 +
<br>'''Fig. 5''' Typical connection diagram
 +
 +
===Connection of the actuators===
 +
 +
 +
 +
====Connection of the lights/electric contactor/heating thermal actuator====
 +
 +
{| class="wikitable" style="width:800px";
 +
|-
 +
|[[File:mf10exa4.jpg|350px|lamp]]<br>'''Fig. 6'''|| style="margin:20px"|Such actuators as light, electric contactor, heating thermal actuator should be switched on any of the outputs 1 – 10, the neutral wire and the ground wire should be connected directly to the switchboard. The example of connection is shown in '''Fig.6'''.
 +
|}
 +
 +
 +
 +
====Connection of high load device====
 +
 +
{| class="wikitable" style="width:800px";
 +
|-
 +
|[[File:mf10exa5.png|350px|Contactor]]|| style="margin:20px"|Recomended contactors:
 +
*ABB ESB series
 +
*Schneider Acti 9 iCT series
 +
*Hager ESC series.
 +
|}
 +
 +
 +
 +
====Connection of single-pole water/gas supply valve====
 +
 +
{| class="wikitable" style="width:800px";
 +
|-
 +
|colspan="2" style="background-color:#dededf" |'''Caution: Before applying power to the load, make sure that the output configuration of METAFORSA module is correct. The incorrect configuration or incorrect connection can cause the module failure and/or failure of the equipment connected to it, and even a fire.'''
 +
|-
 +
|[[File:mf10exa6.jpg|350px|valve]]<br>'''Fig. 7'''|| style="margin:20px"|The single pole water/gas supply valve is connected to any of the outputs of 1 – 10, the (neutral wire and the ground wire are connected directly to the switchboard. The example of connection is shown in '''Fig.7'''.
 +
|}
 +
 +
 +
 +
====Connection of double-pole water/gas supply valve====
 +
 +
{| class="wikitable" style="width:800px";
 +
|-
 +
|colspan="2" style="background-color:#dededf" |'''Caution: Before applying power to the valve, it is necessary to ensure the output configuration of METAFORSA module is correct. The incorrect configuration can cause the voltage application simultaneously to both channels of the valve, which may result in the module failure and/or failure of the equipment connected to it, and even a fire.'''
 +
|-
 +
|[[File:mf10exa7.jpg|350px|valve]]<br>'''Fig. 8'''|| style="margin:20px"|Two adjacent contact points (for example, 3, 4) are used to connect the double-pole water/gas supply valve; in these conditions the neutral wire and the ground wire are connected directly to the switchboard. The example of connection is shown in '''Fig.8'''.
 +
|}
 +
 +
 +
 +
====Connection of single-pole gate actuator====
 +
 +
{{ConExC
 +
|Caution: Before applying power to the module, you should properly configure access to the application. The contacts incorrectly configured can result in the module failure and/or failure of the equipment connected to it, and even a fire.
 +
|mf10exa8|Fig. 9|Any contact point (for example, 3) is used to connect the single-pole gate drive controllers. The example of connection is shown in '''Fig.9'''.
 +
}}
 +
 +
 +
 +
====Connection of double-pole gate actuator====
 +
 +
{{ConExC
 +
|Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.
 +
|mf10exa9|Fig. 10|Two adjacent contact points (for example, 3, 4) should be used to connect the double-pole gate drive controller. The example of connection is shown in '''Fig.10'''.
 +
}}
 +
 +
 +
 +
====Connection of curtain/jalousie/shutter actuator with 220V force control====
 +
 +
{{ConExC
 +
|Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.
 +
|Pjalousie|Fig. 9|Two adjacent contact points (for example, 3, 4) should be used to connect the curtain/jalousie/rolladens actuator, in these conditions the neutral wire and the ground wire are connected directly to the switchboard. The example of connection is shown in '''Fig.9.'''
 +
}}
 +
 +
 +
 +
====Connection of curtain/jalousie/shutter actuator with low-voltage control====
 +
 +
{{ConExC
 +
|Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.
 +
|ljalousie|Fig. 10|Two adjacent contact points (for example, 3, 4) should be used to connect the curtain/jalousie/rolladens actuator with low-voltage control. The example of connection is shown in '''Fig.10'''.
 +
}}

Navigation menu