Line 395: Line 395:  
'''Fig. 14'''
 
'''Fig. 14'''
 
|}
 
|}
 +
 +
'''Configuration and connection of the Satel AMBER sensor''' The configuration of Satel Amber is shown in fig. 14 and consists of the following major elements:
 +
 +
#LED status indicator/
 +
#LED contact is used to turn on and off the LED display.
 +
#SENS contacts are used to set the sensitivity of the sensor. If the contacts are closed, the high sensitivity is set. If the contacts are open, the low sensitivity is set.
 +
#Terminals:
 +
#*'''+12V''' — sensor power is connected to the contact point of METAFORSA “+12V”
 +
#*'''COM''' — common, connected to the input of METAFORSA “GND”
 +
#*'''NC''' — danger relay contact, a jumper is applied at СОМ
 +
#*'''NC''' — danger relay contact, connected to the input of METAFORSA “in 1-16”
 +
#*'''TMP''' — not in use
 +
#*'''TMP''' — not in use
    
====Connection of FW-WL.A leakage sensors====
 
====Connection of FW-WL.A leakage sensors====