| #Disconnect the connectors (8)-(14). | | #Disconnect the connectors (8)-(14). |
| #Remove the module from the DIN-rail, releasing the latch at the bottom of the module base. | | #Remove the module from the DIN-rail, releasing the latch at the bottom of the module base. |
| + | |
| + | ==Hardware setup== |
| + | |
| + | To configure and control METAFORSA SMART HOUSE, you must install Larnitech software on your smartphone or tablet, which is available in [https://itunes.apple.com/us/app/larnitech/id1108457530?mt=8 App Store] and [https://play.google.com/store/apps/details?id=com.larnitech Play Market]. After installation, follow the '''System Setup Instructions'''. |
| + | |
| + | ==Fault diagnostics and handling== |
| + | |
| + | The following are some possible faults and ways of fault handling. If you have any difficulty, or face the fault undeclared here, please contact the Technical Support: [http://www.larnitech.com/support/] or [support@larnitech.com]. |
| + | There are also some tips in the FAQ section at our website [http://www.larnitech.com/faq/]. |
| + | |
| + | ===The actuators do not operate:=== |
| + | |
| + | *ensure the outputs are properly configured in the application (see '''System Setup Instructions'''); |
| + | *check the connection is correct in accordance with '''table 2 and''' paragraph 3.6; |
| + | *ensure the power is supplied to the input power contact , i.e. all circuit breaker assembly are ON. |
| + | *verify the operability of the connected equipment. |
| + | |
| + | ===The module is off, indication absent:=== |
| + | |
| + | *check the connection to 24V supply unit as shown in '''table 2''' (contacts pin assignment); |
| + | *check the connection of the supply unit to 220V power mains, the indicator should be ON. |
| + | |
| + | ===Network connection fault:=== |
| + | |
| + | *ensure the Ethernet cable is properly wired and connected to the connector; |
| + | *ensure the LED status indicators are ON on the Ethernet connector; |
| + | *check the LAN configuration is correct, Ethernet cable loops are absent; |
| + | *METAFORSA module and the device you are connecting from are in the same network. |
| + | |
| + | hold integer 0-10000 1-10 by default hold is the same as runtime |
| + | hold is the bridging time in miliseconds, is used for gate and jalousie, lock; Example: hold=3500 |
| + | |
| + | |
| + | ===The sensors do not operate:=== |
| + | |
| + | *ensure the inputs are properly configured in the application ('''System Setup Instructions'''); |
| + | *check the connection is correct in accordance with '''table 2''' and paragraph 3.7; |
| + | *ensure the METAFORSA module is ON: circuit breaker assembly is closed, indication on the supply unit is ON, the module indication corresponds to the operating status – '''table 3'''; |
| + | *check the power supply availability on the sensors; |
| + | *check the integrity of lines laid to the sensors. |
| + | |
| + | ===The auxiliary equipment does not operate:=== |
| + | |
| + | *check the connection is correct in accordance with table 2 and paragraph 3.8-9; |
| + | *ensure the METAFORSA module is ON: circuit breaker assembly is closed, indication on the supply unit is ON, the module indication corresponds to the operating status – table 3; |
| + | *check the integrity of the CAN lines, voltage supply on the modules. |