Line 1: |
Line 1: |
| {{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}} | | {{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}} |
| {{Infobox module | | {{Infobox module |
− | | name = DW-LC10.B | + | | name = DW-LC10.A |
− | | image = DW-LC10B.png | + | | image = DW-LC10A.png |
| | outCount = 10 | | | outCount = 10 |
| | dimmOut = | | | dimmOut = |
− | | peakl = 16A | + | | peakl = 8A |
| | peakdl = | | | peakdl = |
| | dt = | | | dt = |
Line 11: |
Line 11: |
| | inDigit = | | | inDigit = |
| | voltage = 11.5...27.5 V DC | | | voltage = 11.5...27.5 V DC |
− | | dim = 4U, 69x115x58 mm | + | | dim = 6U, 105x115x58 mm |
| }} | | }} |
| | | |
− | ==18-CHANNEL ACTUATOR== | + | ==10-CHANNEL ACTUATOR== |
| | | |
| This module is designed for high power AC/DC circuits commutation. | | This module is designed for high power AC/DC circuits commutation. |
Line 53: |
Line 53: |
| ==Overview== | | ==Overview== |
| | | |
− | [[File:LC10B VIEW.png|500px]] | + | [[File:LC10A VIEW.jpg|500px]] |
| | | |
| ==Example of connection== | | ==Example of connection== |
| | | |
− | [[File:LC10B EXA.png|500px]] | + | [[File:LC10A EXA.png|500px]] |
| | | |
| ==Module dimensions== | | ==Module dimensions== |
| | | |
− | [[File:LC10B DIMM.png|500px]] | + | [[File:LC10A DIMM.png|500px]] |
| | | |
| + | ==Internal layout== |
| + | |
| + | [[File:LC10A IL.png|500px]] |
| ==Module parameters== | | ==Module parameters== |
| | | |
Line 69: |
Line 72: |
| | involtage = 0-250V | | | involtage = 0-250V |
| | currtype = AC/DC | | | currtype = AC/DC |
− | | maxperch = 16A | + | | maxperch = 8A |
| + | | maxpergroup = 20A |
| + | | maxperdev = 60A |
| | power = 11.5 … 27.5 V DC from CAN | | | power = 11.5 … 27.5 V DC from CAN |
| | maxcur24v = 200 mA | | | maxcur24v = 200 mA |
Line 80: |
Line 85: |
| | protection = IP40 | | | protection = IP40 |
| | temprange = -10 … +50 °C | | | temprange = -10 … +50 °C |
− | | size = 4U, 69x115x58 mm | + | | size = 6U, 105x115x58 mm |
| | weight = 250 g | | | weight = 250 g |
| }} | | }} |
Line 89: |
Line 94: |
| The nominal value of the circuit breaker should be calculated based on the maximum total load of connected | | The nominal value of the circuit breaker should be calculated based on the maximum total load of connected |
| devices and at the same time should not significantly exceed the maximum permissible characteristics of the actuator. | | devices and at the same time should not significantly exceed the maximum permissible characteristics of the actuator. |
− | Depending on the requirements, you can use one circuit breaker for one actuator (it is recommended) | + | Depending on the requirements, you can use one circuit breaker for one actuator (it is recommended, see Fig. 1) |
− | or one circuit breaker per each group of connected loads, or, if necessary, a separate circuit breaker can be installed | + | or one circuit breaker per each group of connected loads (see Fig. 2), or, if necessary, a separate circuit breaker can be installed |
− | for each load. | + | for each load (see Fig. 3)<br> |
| + | [[File:LC10Aexa1.png|500px]] |
| | | |
| ==Connection of actuators== | | ==Connection of actuators== |
− |
| |
| <div class="caution"> Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire. | | <div class="caution"> Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire. |
| If free (unused) channels remain in a given group after a curtain/jalousie/shutter actuator with low-voltage control or gate actuator has been connected to it, these channels need to be left unused. (Do not connect other devices to them!) </div> | | If free (unused) channels remain in a given group after a curtain/jalousie/shutter actuator with low-voltage control or gate actuator has been connected to it, these channels need to be left unused. (Do not connect other devices to them!) </div> |
Line 100: |
Line 105: |
| ===Connection of the lights/electric contactor/heating thermal actuator=== | | ===Connection of the lights/electric contactor/heating thermal actuator=== |
| | | |
− | [[File:lamps.png|200px]]<br> | + | [[File:LC18Aexa2.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
| <syntaxhighlight lang="xml" line> | | <syntaxhighlight lang="xml" line> |
− | hw="out='LLL-------'" | + | hw="out='LLLL'" |
| </syntaxhighlight> | | </syntaxhighlight> |
| + | |
| | | |
| ===Connection of high load device=== | | ===Connection of high load device=== |
Line 110: |
Line 116: |
| {| class="wikitable" style="width:800px"; | | {| class="wikitable" style="width:800px"; |
| |- | | |- |
− | |[[File:Contactor.png|200px|Contactor]]|| style="margin:20px"|Recomended contactors: | + | |[[File:LC18Aexa3.png|200px|Contactor]]|| style="margin:20px"|Recomended contactors: |
| *ABB ESB series | | *ABB ESB series |
| *Schneider Acti 9 iCT series | | *Schneider Acti 9 iCT series |
Line 118: |
Line 124: |
| ===Connection of curtain/jalousie/shutter actuator with 220V force control=== | | ===Connection of curtain/jalousie/shutter actuator with 220V force control=== |
| | | |
− | [[File:Pjalousie.png|200px]]<br> | + | [[File:LC18Aexa4.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
| <syntaxhighlight lang="xml" line> | | <syntaxhighlight lang="xml" line> |
− | hw="out='B---------'" | + | hw="out='--B-'" |
| </syntaxhighlight> | | </syntaxhighlight> |
| | | |
| ===Connection of curtain/jalousie/shutter actuator with low-voltage control=== | | ===Connection of curtain/jalousie/shutter actuator with low-voltage control=== |
| | | |
− | [[File:Ljalousie.png|200px]]<br> | + | [[File:LC18Aexa5.jpg|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
| <syntaxhighlight lang="xml" line> | | <syntaxhighlight lang="xml" line> |
− | hw="out='B---------'" | + | hw="out='--B-'" |
| </syntaxhighlight> | | </syntaxhighlight> |
| | | |
| ===Connection of single-pole gate actuator=== | | ===Connection of single-pole gate actuator=== |
| | | |
− | [[File:1pgate.png|200px]]<br> | + | [[File:LC18Aexa6.jpg|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
| <syntaxhighlight lang="xml" line> | | <syntaxhighlight lang="xml" line> |
− | hw="out='X---------'" | + | hw="out='---X'" |
| </syntaxhighlight> | | </syntaxhighlight> |
| | | |
| ===Connection of double-pole gate actuator=== | | ===Connection of double-pole gate actuator=== |
| | | |
− | [[File:2pgate.png|200px]]<br> | + | [[File:LC18Aexa7.jpg|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
| <syntaxhighlight lang="xml" line> | | <syntaxhighlight lang="xml" line> |
− | hw="out='G---------'" | + | hw="out='--G-'" |
| </syntaxhighlight> | | </syntaxhighlight> |
| + | |
| + | |
| | | |
| ===Connection of single-pole water/gas supply valve=== | | ===Connection of single-pole water/gas supply valve=== |
| | | |
− | [[File:1pvalve.png|200px]]<br> | + | [[File:LC18Aexa8.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
| <syntaxhighlight lang="xml" line> | | <syntaxhighlight lang="xml" line> |
− | hw="out='R---------'" | + | hw="out='---R'" |
| </syntaxhighlight> | | </syntaxhighlight> |
| | | |
| ===Connection of double-pole water/gas supply valve=== | | ===Connection of double-pole water/gas supply valve=== |
| | | |
− | [[File:2pvalve.png|200px]]<br> | + | [[File:LC18Aexa9.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
| <syntaxhighlight lang="xml" line> | | <syntaxhighlight lang="xml" line> |
− | hw="out='V---------'" | + | hw="out='--V-'" |
| </syntaxhighlight> | | </syntaxhighlight> |
| | | |
| ===Connection of fancoil control unit=== | | ===Connection of fancoil control unit=== |
| | | |
− | [[File:fancoil.png|200px]]<br> | + | [[File:LC18Aexa10.png|200px]]<br> |
| Sample HW for this configuration | | Sample HW for this configuration |
| <syntaxhighlight lang="xml" line> | | <syntaxhighlight lang="xml" line> |
− | hw="out='FFF-------'" | + | hw="out='FFFF'" |
| </syntaxhighlight> | | </syntaxhighlight> |
− |
| |
| ==Indication of module operation== | | ==Indication of module operation== |
− | ===Bootloader===
| + | {{indicationold}} |
− | {{indication| textBBB= Waiting for bootloader command}} | |
− | ===Firmware===
| |
− | {{indicationfw
| |
− | |topgl = 1
| |
− | |topyl = 0
| |
− | |err1 = 1
| |
− | |err2 = 1
| |
− | }} | |
| | | |
| ==Module installation and connection procedure== | | ==Module installation and connection procedure== |
Line 205: |
Line 204: |
| |- | | |- |
| |runtime||integer 0-100||1-10||15||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15 | | |runtime||integer 0-100||1-10||15||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15 |
− | |-
| |
− | |runtimeopen||integer 0-60000||Blinds subId|| – ||Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000
| |
− | |-
| |
− | |runtimeclose||integer 0-60000||Blinds subId|| – ||Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000
| |
| |- | | |- |
| |hold||integer 0-10000||1-10||500||hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500 | | |hold||integer 0-10000||1-10||500||hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500 |
Line 245: |
Line 240: |
| | | |
| <syntaxhighlight lang="xml" line> | | <syntaxhighlight lang="xml" line> |
− | <item addr="300:1" cfgid="98" hw="runtime=60" name="Jalousie" sub-type="120" type="jalousie" uniq_id="117"/> | + | <item addr="300:1" cfgid="61" hw="runtime=60" name="Jalousie" sub-type="120" type="jalousie" uniq_id="117"/> |
− | <item addr="300:3" auto-period="600" cfgid="98" hw="def='ON'" name="Lamp" type="lamp" uniq_id="110"/> | + | <item addr="300:3" auto-period="600" cfgid="61" hw="def='ON'" name="Lamp" type="lamp" uniq_id="110"/> |
− | <item addr="300:4" cfgid="98" hw="runtime=30" name="Gate" sub-type="120" type="gate" uniq_id="118"/> | + | <item addr="300:4" cfgid="61" hw="runtime=30" name="Gate" sub-type="120" type="gate" uniq_id="118"/> |
− | <item addr="300:6" auto-period="600" cfgid="98" hw="hold=5000" name="Lamp" type="lamp" uniq_id="113"/> | + | <item addr="300:6" auto-period="600" cfgid="61" hw="hold=5000" name="Lamp" type="lamp" uniq_id="113"/> |
− | <item addr="300:7" cfgid="98" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="119"> | + | <item addr="300:7" cfgid="61" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="119"> |
| <automation name="Eco" temperature-level="16" uniq_id="120"/> | | <automation name="Eco" temperature-level="16" uniq_id="120"/> |
| <automation name="Comfort" temperature-level="22" uniq_id="121"/> | | <automation name="Comfort" temperature-level="22" uniq_id="121"/> |
| <automation name="Hot" temperature-level="25" uniq_id="122"/> | | <automation name="Hot" temperature-level="25" uniq_id="122"/> |
| </item> | | </item> |
− | <item addr="300:8" cfgid="98" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="123"> | + | <item addr="300:8" cfgid="61" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="123"> |
| <automation name="Eco" temperature-level="16" uniq_id="124"/> | | <automation name="Eco" temperature-level="16" uniq_id="124"/> |
| <automation name="Comfort" temperature-level="22" uniq_id="125"/> | | <automation name="Comfort" temperature-level="22" uniq_id="125"/> |
| <automation name="Hot" temperature-level="25" uniq_id="126"/> | | <automation name="Hot" temperature-level="25" uniq_id="126"/> |
| </item> | | </item> |
− | <item addr="300:10" cfgid="98" hw="hold=2000" name="Gate" sub-type="120" type="gate" uniq_id="127"/> | + | <item addr="300:10" cfgid="61" hw="hold=2000" name="Gate" sub-type="120" type="gate" uniq_id="127"/> |
− | <item addr="300:97" cfgid="98" name="Temperature" system="yes" type="temperature-sensor" uniq_id="106"/> | + | <item addr="300:97" cfgid="61" name="Temperature" system="yes" type="temperature-sensor" uniq_id="106"/> |
− | <item addr="300:98" cfgid="98" hw="out='BLGKHJ-X'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="107"/> | + | <item addr="300:98" cfgid="61" hw="out='BLGKHJ-X'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="107"/> |
| </syntaxhighlight> | | </syntaxhighlight> |