Changes
Jump to navigation
Jump to search
1,646 bytes added
, 13:56, 25 January 2022
<languages/>
Air conditioner virtual device
===Example of description in XML===
<syntaxhighlight lang="xml" line>
<item addr="335:112" name="Conditioner" type="conditioner" vane-ver="0x3"/> // Conditioner virtual device description
<import-script id="335" CONDID="140" IRID="335:17" path="conditioner-MITS-4.txt"/> // Conditioner control script description
//Description with the help of one tag:
<item IRT="566:64" addr="566:250" name="conditioner" script-id="con" path="scripts/con.txt" type="conditioner"/>
</syntaxhighlight>
===Additional parameters===
{|class="wikitable"
|-
!Name!!type and variety!!description!!default value
|-
|path*||string||Path to script||-
|-
|script-id||string||script id from the description for interface||-
|-
|t-min||number||temperature low value||16
|-
|t-delta||number||temperature range||16
|-
|modes||bit mask||Mask of operation modes||0xFF
|-
|funs||bit mask||Mask of airflow mode||0xFF
|-
|vane-ver||bit mask||Mask of vertical fins mode||0xFF
|-
|vane-hor||bit mask||Mask of horizontal fins mode||0xFF
|-
|temperature-sensors||list||list of valve temperature sensors||-
|}
<nowiki>*</nowiki> – required fields
===Device status (6 bytes)===
{|class="wikitable"
|-
!Byte number!!Description
|-
|0||0 bit – 0 is off, 1 is on<br>4-7th bit – mode of operation<br>0 – Fan,<br>1 – Cool,<br>2 – Dry,<br>3 – Heat,<br>4 – Auto.
|-
|1||temperature (t-min is to be added to the value)
|-
|2||reserved
|-
|3||0-3d bit – position of horizontal fins<br>4-7th bit – position of vertical fins
|-
|4||0-3d bit – airflow capacity
|}
===Status setting===
from the 1st to the 6th correspondingly
editor, translation-admin, translator