Translations:BW-RGB/15/en

HW settings

Name Type, range SUBID Default Description
dm char[3] 98 'RGB' Each char is responsible for the type of a particular channel, RGB takes 3 channels
  • 'D' – use like dimmer-lamp
  • 'RGB' – Use like RGB lamp

Example: dm='DDD'

def integer 0-250 1-3 100 The default brightness level in case of a power reset (1..250). Example: def=250
min integer 0-100 1-3 0 Minimum dimming level, example: min=10
max integer 0-100 1-3 100 Maximum dimming level, example max=95
runtime integer 0-100 98 5 Runtime is the speed of changing the brightness(measured in seconds). Example: runtime=15
f integer 1-1000 98 500 It is frequency (measured in Hz); Example: f=500