Translations:Tag automation/6/en

From Larnitech wiki page
Jump to navigation Jump to search
  1. enabled – automation activating (="yes") or disactivating (="no")
  2. door-sensors, motion-sensors, illumination-sensors – the addresses of sensors of corresponding type applied for automation (several sensors are specified via, for example 533:10;525:12)
  3. motion-level, illumination-level – reading levels of corresponding sensors
  4. time-interval – timing range operation of sensors readings levels
  5. time-intervals – parameter in the format of 7 consecutive repeating successions of hexadecimal notations like XXXXXXXXXXXX (their length is 12 symbols, per each day of the week starting from SUNDAY), symbolizing bitwise automation activity half-hour periods of time (i.e. each number equals to 2 hours exactly)
    Examples:
    time-intervals="000000000000000000000000000000000000000000000000000000000000000000000000000000000000" – it doesn’t operate ever:
    time-intervals="FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF" – it operates always:
    time-intervals="FFFFFFFFFFFF0000FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF" – it doesn’t operate only on Tuesday till 8 a.m.
  6. delay – off delay parameter on movement in automation of switching off according to the door after its closing