Difference between revisions of "WW-WL.B"
Jump to navigation
Jump to search
(Created page with "<languages/> <translate> <!--T:1--> {{RevisionChanger | hasA = 1 | hasB = 1}} {{Infobox module | name = FW-WL.B | image = FW-WLB.png | voltage = 9-12 V DC | dim...") |
|||
(2 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
<translate> | <translate> | ||
<!--T:1--> | <!--T:1--> | ||
− | |||
{{Infobox module | {{Infobox module | ||
− | | name = | + | | name = WW-WL.B |
− | | image = | + | | image = WW-WLB.png |
| voltage = 9-12 V DC | | voltage = 9-12 V DC | ||
| dim = 57x47x22 mm | | dim = 57x47x22 mm | ||
}} | }} | ||
− | == | + | ==WALL LEAKAGE SENSOR== <!--T:2--> |
<!--T:3--> | <!--T:3--> | ||
− | The sensor is placed on the | + | The sensor is placed on the wall. |
− | |||
Used together with DW-WL02 or BW-LSA modules. | Used together with DW-WL02 or BW-LSA modules. | ||
==Features== <!--T:4--> | ==Features== <!--T:4--> | ||
*Sensor presence detection | *Sensor presence detection | ||
− | |||
*Adjusting the sensor sensitivity | *Adjusting the sensor sensitivity | ||
*Connections of several sensors to one bus | *Connections of several sensors to one bus | ||
Line 26: | Line 23: | ||
<!--T:6--> | <!--T:6--> | ||
− | [[File: | + | [[File:WWWLB_EXA.png|400px]] |
− | |||
− | |||
− | |||
− | |||
− | |||
==Module parameters== <!--T:9--> | ==Module parameters== <!--T:9--> | ||
Line 53: | Line 45: | ||
!Name!!Type, range!!SUBID!!Default!!Description | !Name!!Type, range!!SUBID!!Default!!Description | ||
|- | |- | ||
− | + | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|sens||int||sensors subId||128||Sensor sensitivity | |sens||int||sensors subId||128||Sensor sensitivity | ||
Example: | Example: | ||
Line 112: | Line 57: | ||
<!--T:12--> | <!--T:12--> | ||
* Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly. | * Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly. | ||
− | |||
</translate> | </translate> |
Latest revision as of 09:50, 18 August 2022
WW-WL.B | |||||||
---|---|---|---|---|---|---|---|
|
WALL LEAKAGE SENSOR
The sensor is placed on the wall. Used together with DW-WL02 or BW-LSA modules.
Features
- Sensor presence detection
- Adjusting the sensor sensitivity
- Connections of several sensors to one bus
Example of connection
Module parameters
Parameter name | Value |
---|---|
Power supply | 9-12 V DC |
Max current(24V) | 20 mA |
Compatible with | Metaforsa devices DW-WL02/HTxx BW-LSA |
Equipment installation type | Free |
Case material | ABS |
Protection | IP64 |
Temperature range | -10 … +50 °C |
Size | 57x47x22 mm |
Weight | 35g |
HW settings
Name | Type, range | SUBID | Default | Description |
---|---|---|---|---|
sens | int | sensors subId | 128 | Sensor sensitivity
Example: 1sens='180'
|
test | int(0,1) | sensors subId | 1 | 0 - Disable the test signal to detect the presence of the sensor |
- Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly.