Changes

Jump to navigation Jump to search
1,341 bytes removed ,  17 April
m
Edit involtage
Line 7: Line 7:  
| peakl      = 3A
 
| peakl      = 3A
 
| voltage    = 12/24 V DC
 
| voltage    = 12/24 V DC
| dim        = ??x??x?? mm
+
| dim        = 65x18x15 mm
 
}}
 
}}
   Line 35: Line 35:     
<!--T:6-->
 
<!--T:6-->
[[File:LED-DRV_connection_scheme.png|800px]]
+
[[File:LED-DRV_connection_scheme.png|600px]]
    
==Module parameters== <!--T:7-->
 
==Module parameters== <!--T:7-->
Line 42: Line 42:  
{{ Mp
 
{{ Mp
 
| outqty          = 4
 
| outqty          = 4
| involtage      = 11.5 … 25V
+
| involtage      = 5V
 
| currtype        = DC
 
| currtype        = DC
 
| adjtype        = PWM
 
| adjtype        = PWM
| maxperch        = 1A (12W at 12V)
+
| maxperch        = 3A
| maxperdev      = 3A (36W at 12V)
+
| power          = 11.5 … 27.5 V DC
| power          = 11.5 … 27.5 V DC from CAN
  −
| maxcur24v      = 25 mA
   
| instalation    = Free
 
| instalation    = Free
 
| case            = ABS
 
| case            = ABS
 
| protection      = IP40
 
| protection      = IP40
 
| temprange      = -10 … +50 °C
 
| temprange      = -10 … +50 °C
| size            = 45x42x14 mm
+
| size            = 65x18x15 mm
 
| weight          = 25 g
 
| weight          = 25 g
 
}}
 
}}
Line 61: Line 59:  
<!--T:9-->
 
<!--T:9-->
 
#Connect the outputs.
 
#Connect the outputs.
#Configure the module using LT setup.
+
#Configure the module using LT Setup.
 
#Apply power to the load.
 
#Apply power to the load.
 
#Check all equipment for proper operation.
 
#Check all equipment for proper operation.
Line 70: Line 68:  
#Disconnect the power from the load.
 
#Disconnect the power from the load.
 
#Disconnect the outputs.
 
#Disconnect the outputs.
  −
==HW settings== <!--T:12-->
  −
{|class="wikitable"
  −
|-
  −
!Name!!Type, range!!SUBID!!Default!!Description
  −
|-
  −
|dm||char[3]||98||'RGB'||Each char is responsible for the type of a particular channel, RGB takes 3 channels
  −
*'D' – use like dimmer-lamp
  −
*'RGB' – Use like RGB lamp
  −
Example: dm='DDD'
  −
|-
  −
|def||integer 0-250||1-3||100||The default brightness level in case of a power reset (1..250). Example: def=250
  −
|-
  −
|min||integer 0-100||1-3||0||Minimum dimming level, example: min=10
  −
|-
  −
|max||integer 0-100||1-3||100||Maximum dimming level, example max=95
  −
|-
  −
|runtime||integer 0-100||98||5||Runtime is the speed of changing the brightness(measured in seconds). Example: runtime=15
  −
|-
  −
|f||integer 1-1000||98||500||It is frequency (measured in Hz); Example: f=500
  −
|}
  −
  −
<!--T:16-->
  −
<syntaxhighlight lang="xml" line>
  −
<item addr="355:1" auto-period="600" cfgid="175" name="Dimmer" type="dimer-lamp" uniq_id="68"/>
  −
<item addr="355:2" auto-period="600" cfgid="175" name="Dimmer" type="dimer-lamp" uniq_id="69"/>
  −
<item addr="355:3" auto-period="600" cfgid="175" name="Dimmer" type="dimer-lamp" uniq_id="70"/>
  −
<item addr="355:98" cfgid="175" hw="dm='DDD' f=1000 runtime=20" name="Temperature" system="yes" type="temperature-sensor" uniq_id="47"/>
  −
</syntaxhighlight>
 
editor, Interface administrators, Administrators, translation-admin, translator
9,706

edits

Navigation menu