Changes

219 bytes added ,  13:20, 6 January 2022
Marked this version for translation
Line 1: Line 1:  
<languages/>
 
<languages/>
 
<translate>
 
<translate>
 +
<!--T:1-->
 
{{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}}
 
{{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}}
 
{{Infobox module
 
{{Infobox module
Line 16: Line 17:  
}}
 
}}
   −
==3-CHANNEL MODULE FOR BLINDS MOTOR CONTROL==
+
==3-CHANNEL MODULE FOR BLINDS MOTOR CONTROL== <!--T:2-->
    +
<!--T:3-->
 
This module provides control of curtains, projector screens, valves or other electrical motors.
 
This module provides control of curtains, projector screens, valves or other electrical motors.
   −
==Features==
+
==Features== <!--T:4-->
 
*Supported load types:
 
*Supported load types:
 
**curtains with force/low-current control
 
**curtains with force/low-current control
Line 27: Line 29:  
*Built-in current sensor
 
*Built-in current sensor
    +
<!--T:5-->
 
<div class="caution">
 
<div class="caution">
 
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
 
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
Line 43: Line 46:  
</div>
 
</div>
   −
==Overview==
+
==Overview== <!--T:6-->
    +
<!--T:7-->
 
[[File:BC03C VIEW.png|500px]]
 
[[File:BC03C VIEW.png|500px]]
   −
==Connection of curtain/jalousie/shutter actuators==
+
==Connection of curtain/jalousie/shutter actuators== <!--T:8-->
    +
<!--T:9-->
 
[[File:BC03C EXA.png|500px]]
 
[[File:BC03C EXA.png|500px]]
   −
==Module dimensions==
+
==Module dimensions== <!--T:10-->
    +
<!--T:11-->
 
[[File:BC03C DIM.png|500px]]
 
[[File:BC03C DIM.png|500px]]
   −
==Internal layout==
+
==Internal layout== <!--T:12-->
    +
<!--T:13-->
 
[[File:BC03C IL.png|500px]]
 
[[File:BC03C IL.png|500px]]
      −
==Module parameters==
+
==Module parameters== <!--T:14-->
    +
<!--T:15-->
 
{{ Mp
 
{{ Mp
 
| outqty          = 3
 
| outqty          = 3
Line 81: Line 89:  
}}
 
}}
   −
==Indication of module operation==
+
==Indication of module operation== <!--T:16-->
 
===Bootloader===
 
===Bootloader===
 
{{indication| textBBB= Waiting for bootloader command}}
 
{{indication| textBBB= Waiting for bootloader command}}
Line 91: Line 99:  
}}
 
}}
   −
==Module installation and connection procedure==
+
==Module installation and connection procedure== <!--T:17-->
 
#Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base.
 
#Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base.
 
#Connect the CAN connector.
 
#Connect the CAN connector.
Line 99: Line 107:  
#Check all equipment for proper operation.
 
#Check all equipment for proper operation.
   −
==Module shut-off and deinstallation procedure==
+
==Module shut-off and deinstallation procedure== <!--T:18-->
 
#Disconnect the power from the load.
 
#Disconnect the power from the load.
 
#Disconnect the channels.
 
#Disconnect the channels.
Line 105: Line 113:  
#Remove the module from the DIN rail, releasing the latch at the bottom of the module base.
 
#Remove the module from the DIN rail, releasing the latch at the bottom of the module base.
   −
==HW settings==
+
==HW settings== <!--T:19-->
 
{|class="wikitable"
 
{|class="wikitable"
 
|-
 
|-
editor, translation-admin, translator
4,754

edits