Changes
	
		
		
		
		
		
		Jump to navigation
		Jump to search
		
	
	
	
		157 bytes removed
	
		,  11:49, 29 March 2024
	
 
m| Line 5: | 
Line 5: | 
|   | | image      = LED-DRV_3A.png  |   | | image      = LED-DRV_3A.png  | 
|   | | outCount   = 4  |   | | outCount   = 4  | 
| − | | peakl      = 2A  | + | | peakl      = 3A  | 
|   | | voltage    = 12/24 V DC  |   | | voltage    = 12/24 V DC  | 
|   | | dim        = ??x??x?? mm  |   | | dim        = ??x??x?? mm  | 
| Line 13: | 
Line 13: | 
|   |  |   |  | 
|   | <!--T:3-->  |   | <!--T:3-->  | 
| − | This module allows interpreting controlling signal from DW-IO for 12/24V LED/RGB strip.  | + | This module allows interpretation of controlling signals from IO connections for 12/24V LED/RGB strips.  | 
|   |  |   |  | 
|   | <!--T:4-->  |   | <!--T:4-->  | 
| Line 35: | 
Line 35: | 
|   |  |   |  | 
|   | <!--T:6-->  |   | <!--T:6-->  | 
| − | [[File:RGBC EXA.png|500px]]  | + | [[File:LED-DRV_connection_scheme.png|800px]]  | 
|   |  |   |  | 
| − | ==Example of connection RGB LED with Amp== <!--T:7-->
  | + | ==Module parameters== <!--T:7-->  | 
| − |    |   | 
| − | <!--T:8-->
  |   | 
| − | [[File:RGBC EXA2.png|500px]]
  |   | 
| − |    |   | 
| − | ==Module parameters== <!--T:9-->  |   | 
|   |  |   |  | 
|   | <!--T:10-->  |   | <!--T:10-->  | 
|   | {{ Mp  |   | {{ Mp  | 
| − | | outqty          = 3  | + | | outqty          = 4  | 
|   | | involtage       = 11.5 … 25V  |   | | involtage       = 11.5 … 25V  | 
|   | | currtype        = DC  |   | | currtype        = DC  | 
| Line 54: | 
Line 49: | 
|   | | power           = 11.5 … 27.5 V DC from CAN  |   | | power           = 11.5 … 27.5 V DC from CAN  | 
|   | | maxcur24v       = 25 mA  |   | | maxcur24v       = 25 mA  | 
| − | | bustype         = CAN (4-wire)
  |   | 
|   | | instalation     = Free  |   | | instalation     = Free  | 
|   | | case            = ABS  |   | | case            = ABS  | 
| Line 63: | 
Line 57: | 
|   | }}  |   | }}  | 
|   |  |   |  | 
| − | ==Module installation and connection procedure== <!--T:11-->  | + | ==Module installation and connection procedure== <!--T:8-->  | 
|   |  |   |  | 
| − | <!--T:12-->  | + | <!--T:9-->  | 
|   | #Connect the outputs.  |   | #Connect the outputs.  | 
| − | #Connect the CAN connector.
  |   | 
|   | #Configure the module using LT setup.  |   | #Configure the module using LT setup.  | 
|   | #Apply power to the load.  |   | #Apply power to the load.  | 
|   | #Check all equipment for proper operation.  |   | #Check all equipment for proper operation.  | 
|   |  |   |  | 
| − | ==Module shut-off and deinstallation procedure== <!--T:13-->  | + | ==Module shut-off and deinstallation procedure== <!--T:10-->  | 
|   |  |   |  | 
| − | <!--T:14-->  | + | <!--T:11-->  | 
|   | #Disconnect the power from the load.  |   | #Disconnect the power from the load.  | 
| − | #Disconnect the CAN connector.
  |   | 
|   | #Disconnect the outputs.  |   | #Disconnect the outputs.  | 
|   |  |   |  | 
| − | ==HW settings== <!--T:15-->  | + | ==HW settings== <!--T:12-->  | 
|   | {|class="wikitable"  |   | {|class="wikitable"  | 
|   | |-  |   | |-  |