Difference between revisions of "Metaforsa 3/3.plus/da"

From Larnitech wiki page
Jump to navigation Jump to search
(Created page with "====WS2812B forbindelsesskema====")
Tags: Mobile web edit Mobile edit
(Created page with "400px<br><br>'''Fig. 16''' WS2812B forbindelse")
Tags: Mobile web edit Mobile edit
Line 424: Line 424:
 
====WS2812B forbindelsesskema====
 
====WS2812B forbindelsesskema====
  
[[File:IOC_CONN_WS.png|400px]]<br><br>'''Fig. 16''' WS2812B connection
+
[[File:IOC_CONN_WS.png|400px]]<br><br>'''Fig. 16''' WS2812B forbindelse
  
 
====RS485 connection scheme====
 
====RS485 connection scheme====

Revision as of 08:24, 8 April 2024

Other languages:
Deutsch • ‎English • ‎Nederlands • ‎bosanski • ‎dansk • ‎español • ‎français • ‎italiano • ‎lietuvių • ‎magyar • ‎polski • ‎português • ‎română • ‎slovenčina • ‎slovenščina • ‎čeština • ‎русский • ‎српски / srpski • ‎українська • ‎Ἀρχαία ἑλληνικὴ
MF3/MF3.plus
METAFORSA 3 MF3-14.png
Output ports
Number of switched channels10
Number of dimming channels4
Peak load16 A
Max load per dimming channel0.5 A (110 W at 220 V)
Dimmer typeMOSFET
Input ports
Number of discrete inputs28
General
Max CAN devices4 (can be extended with the license) 99 (for Metaforsa 3.plus)
Max CAN bus length800 m (twisted pair CAT5e)
Max current per CAN bus500 mA
Other
Supply voltage11.5...27.5 V DC
Dimentions9U, 156x90x58 mm


Introduktion

METAFORSA SMART HOUSE Installationsmanual beskriver proceduren for installation, montering, betjening og indstilling. Mens du arbejder med systemet, skal du nøje overholde alle kravene i denne manual. Manglende overholdelse kan resultere i beskadigelse af enheden, dens fejl, elektrisk stød, brand og andet nedfald. Producenten forbeholder sig retten til at foretage ændringer i denne manual uden forudgående varsel. Denne manual er en integreret del af systemet og forbliver hos slutbrugeren.

Funktioner

  • 10 universelle udgange understøtter:
    • Lys
    • NC/NO varmeventiler
    • Persienner
    • 1 eller 2-polede porte
    • 1 eller 2-polede ventiler
    • NC/NO låse
    • Blæserkonvektorer
  • 4 dæmpningsudgange
  • 28 indgange, der understøtter:
    • Knapper
    • LED-knapper
    • Switcher
    • Reed-kontakter
    • Lækagesensorer
    • Bevægelsesdetektorer
    • Temperatursensorer
    • LED strips
    • 3-4-5 kanals RGB-strimler
    • WS2812B strimler
    • RS485-enheder (kun til Metaforsa 3.plus)
  • Forlængerport
  • Relæer med AgSnO2-kontakter klassificeret til 80A 20ms startstrøm
  • Skyforbindelse og kontrol af alle hussystemer
  • Stemmestyring (Siri, Alexa, Google Home)

Sikkerhedskrav

ADVARSEL! Alt arbejde i forbindelse med installation, tilslutning, opsætning, service og support skal udføres af kvalificeret personale med tilstrækkelige færdigheder og erfaring i at arbejde med elektrisk udstyr.

For at undgå risikoen for brand, elektrisk stød, beskadigelse af systemet og/eller personskade, skal installationen og monteringen af systemet udføres i overensstemmelse med instruktionerne nedenfor:


  • alle tilslutningsarbejder skal udføres uden strøm;
  • brug passende værktøj og personlig beskyttelse mod elektrisk stød;
  • brug ikke beskadigede kabler, ledninger og stik;
  • undgå foldning af kabler og ledninger;
  • undgå at klemme eller knække kabler og ledninger ved at anvende for stor kraft. Ellers kan indvendige ledere af kablet og ledningerne blive strippet eller knækket;
  • brug ikke stikkontakten med dårlige kontakter til at forbinde;
  • overskrid ikke grænsen for belastningsparametre angivet i denne manual;
  • forsyningsledernes ledningssektion er underlagt specifikationerne for strømtæthedsgrænse, isoleringstype og ledningsmateriale. Lyssektion kan resultere i kabeloverophedning og brand.


Når du arbejder med systemet efter spændingsforsyning ALDRIG:

  • foretag tilslutning/frakobling af stik;
  • åbne moduler og sensorer.

Systemkonfiguration og formål

Formål med systemet

METAFORSA SMART HOUSE er en færdiglavet løsning til automatisering af bolig- og erhvervslokaler, hotelkomplekser, som indeholder de mest eftertragtede funktioner i Smart House.


Enheden har 10 kontrolkanaler, 4 dæmpningskanaler og 28 indgangskanaler antal.


Universaludgange kan bruges til at styre: Universalindgange giver dig mulighed for at tilslutte:
Belysning Knapper/LED-knapper/omskiftningsenheder
Stikstik Magnetiske reed-kontakter
Gulvvarme Lækagesensorer
Gardin Bevægelsesdetektorer
Portaktuatorer Temperaturfølere
Vandforsyning LED strips/3-4-5 kanals RGB strips/WS2812B strips
Varmeventiler RS485-enheder*

* – Kun til Metaforsa 3.plus


Udvidelsesport


Udvidelsesporten giver dig mulighed for at opgradere systemet ved at tilslutte ekstraudstyr, såsom styremodulet til LED-belysning, dæmpning, måleenheder og andre elementer. Pakken, som er fuldstændig klar til at installere, inkluderer den grundlæggende hardware og software.

Pakkens indhold

Pakken leveres som standard med:

Mainframe METAFORSA 3/3.plus 1 stk
Strømforsyningsenhed MEANWELL DR-15-12 1 stk
Bevægelsessensor CW-MSD 3 stk
Lækagesensor FW-WL.B 2 stk
Temperaturfølsomt element FW-TS 4 stk
Magnetisk reed-kontakt (vindues-/dørpositionssensor) 4 stk
Ethernet-kabel støjfilter 1 stk
Strømforsyningsledning 1 stk

Grundlæggende tekniske specifikationer for systemet

De grundlæggende specifikationer og egenskaber for modulet METAFORSA 3/3.plus er vist i tabel 1

Tabel 1
Specifikation Betyder
Udgangsporte
Antal skiftede kanaler 10
Antal skiftede grupper 10
Antal dæmpningskanaler 4
Kommuteringsspænding 0-250 V AC/DC
Spidsbelastning (én kanal) 16A
Spidsbelastning (enhed) 160A
Maks. belastning pr. dæmpningskanal 0,5A (110W ved 220V)
Lysdæmper type MOSFET
Lysdæmper belastningstype R,C
Lysdæmpningstype bagkant
Strømforsyningskabeltilslutningstype stik
Tilladt sektion af strømforsyningskablet til tilslutning i stikket:
enkeltlederkabel
flerlederkabel
tilsluttet flerlederkabel

0,5 … 4mm2
0,5 … 4mm2
0,5 … 2,5 mm2
Indgangsporte
Antal diskrete input 28
Maksimal strømstyrke på jævnspændingsstikkene 5 mA*
Andet
Omgivelsestemperatur i drift 0 … +45°С
Opbevarings-/transporttemperatur -10 … +50°С
Tilladt luftfugtighed 0 … 95 % (ikke-kondenserende)
Strømforsyning 11,5 … 27,5 V DC
24V, 0,75A anbefales
Maksimal efterspørgsel 0,5A
Tilgængelige grænseflader Ethernet, CAN
Bustype CAN (4-leder)
CAN (4-leder) 800 m** (parsnoet CAT5e)
CAN ledningstype FTP Cat 5E
CAN-forbindelsestype Stik
Maksimal længde for digital linje 30 m
Digital line wirde type UTP/FTP Cat 5E
LAN maksimal længde 100 m
LAN-ledningstype UTP/FTP Cat 5E
LAN-forbindelsestype Stik RJ-45
RS485 porte antal 1***
Dataoverførselshastighed 1200-115200 b/s***
Dimensionsspecifikationer 9U, 156x90x58 mm
Skalmateriale ABS
Turhus IP40
Installationstype for udstyr DIN-skinne (EN 60715)
Vægt 400 g

* – Udgangskanaler bør kun tilsluttes ved hjælp af en forstærker, der bruger 5V PWM-signal fra IO-udgang som input

** – installation af yderligere strømforsyningsenheder er påkrævet for lange linjer; den maksimale længde af ledningen kan reduceres af forskellige interferensfaktorer

*** – Kun til Metaforsa 3.plus

Systemets generel struktur

Modulets generelle visning er vist i fig. 1


Fig. 1 Generel oversigt over modulet


1 — stik til belastningsanvendelse
2 — stik til dæmpning af lamper
3 — strømstik
4 — Ethernet-netværksstik
5-6 — stik til universelle ind-/udgangskanaler
7 — stik til udvidelsesmodul.


Oversigt over METAFORSA-enhedens eksterne stik: Øverst på kabinettet (fig. 1) er der:


  • stik (1) — Enhedsforbindelse;
  • stik (2) — Tilslutning af dæmpende lamper;


I bunden af kabinettet (fig. 1) er der:


  • stik (3) — modulstrømforsyningsforbindelse;
  • stik (4) — Ethernet-netværksforbindelse;
  • stik (5-6) — universel ind-/udgangskanalforbindelse - knapper, reed-kontakter, LED-knapper, lækagesensorer, bevægelsessensorer, temperatursensorer, LED-strips, 3-4-5 kanals RGB-strips, WS2812B-strips, RS485-enheder ( Kun til Metaforsa 3.plus);
  • stik (7) — udvidelsesmodultilslutning.

Den fysiske konfiguration og tildeling af kontaktpunkter for hvert stik er vist i tabel 2.

Tabel 2
Kontakt Kontakt Opgave
Out.png 1-10 Belastning (lyslamper, termiske aktuatorer osv.)
Dimm.png D1-4, L, N Belastningsanvendelse (dæmpende lamper)
Enhedsstatusindikatorer Modulstatusindikatorerne er beskrevet i tabel 3
24vconn.png +24V
GND
+24V — modulstrømforsyning med en ekstern 24 V strømforsyning GND — fælles
Rj45.jpg RJ45 Stik til LAN-forbindelse
IOC CONN.png In1-14, In15-28 GND Tilslutning af styreenheder (knapper, LED-knapper, magnetiske reed-kontakter, bevægelsesdetektorer, lækagesensorer, temperatursensorer osv.):
In1 … In28 — logiske indgange
GND — fælles
Can.jpg VCC
GND
L
H
Eksterne moduler tilslutning til CAN-bus
VСС — 24V udgang til eksterne enheder strømforsyning
GND — almindelig
L — CAN-L databus
H — CAN-H databus
Table3
Indicator Status Description
Power G.png Power
E.png Power not available
Activity Y.png Data communication
E.png Data communication not available
Error E.png No errors
R.png Communication error
R.pngR.png Module overheat
R.pngR.pngR.png Dimmer outputs module overload
R.pngR.pngR.pngR.png Absence of power on dimmers, if in configuration

Systeminstallation og montering

Før du tilslutter systemet, skal du:


  • placer sensoren og aktuatorerne (hvis de ikke er forudinstalleret), indstil sensorerne og aktuatorerne;
  • placer modulet og strømforsyningen.


Bemærk: Modulet skal installeres i nærheden af strømforsyningsspændingskilden.


ADVARSEL! AC-strømspænding skal leveres til systemindgangen gennem afbryderenheden. Den skal installeres tæt på strømforsyningen.
  1. Styrken til afbryderenheden skal overholde belastningskapaciteten;
  2. Der kan ikke tilsluttes andet end faselederne til modulet, nullederen tilsluttes separat.


Typisk diagram over METAFORSA 3/3.plus modultilslutning er vist i fig. 3.

Fig. 3


Tilslutning af aktuatorer

Tilslutning af lys/elektrisk kontaktor/varme-termisk aktuator

lamp
Fig. 4
Sådanne aktuatorer som lys, elektrisk kontaktor, varme-termisk aktuator bør tændes på enhver af udgangene 1 – 10, neutralledningen og jordledningen skal forbindes direkte til tavlen. Eksemplet på tilslutning er vist i Fig. 4.


Tilslutning af højbelastningsenhed

Contactor Anbefalede kontaktorer:
  • ABB ESB-serien
  • Schneider Acti 9 iCT-serien
  • Hager ESC-serien.


Tilslutning af enpolet vand-/gasforsyningsventil

Forsigtig: Før du tilslutter strøm til belastningen, skal du sikre dig, at outputkonfigurationen af METAFORSA-modulet er korrekt. Den forkerte konfiguration eller forkerte forbindelse kan forårsage modulfejl og/eller fejl på det udstyr, der er tilsluttet det, og endda en brand.
valve
Fig. 5
Den enpolede vand-/gasforsyningsventil er forbundet til en hvilken som helst af udgangene på 1 – 10, (den neutrale ledning og jordledningen er forbundet direkte til tavlen. Eksemplet på tilslutningen er vist i Fig.5.


Tilslutning af dobbeltpolet vand/gas forsyningsventil

Forsigtig: Før der tilføres strøm til ventilen, er det nødvendigt at sikre, at outputkonfigurationen af METAFORSA-modulet er korrekt. Den forkerte konfiguration kan forårsage, at spændingen påføres samtidigt til begge ventilens kanaler, hvilket kan resultere i modulfejl og/eller fejl på det tilsluttede udstyr og endda en brand.
valve
Fig. 6
To tilstødende kontaktpunkter (f.eks. 3, 4) bruges til at forbinde den dobbeltpolede vand-/gasforsyningsventil; under disse forhold er neutralledningen og jordledningen forbundet direkte til tavlen. Eksemplet på tilslutning er vist i Fig.6.


Tilslutning af enpolet portaktuator

Forsigtig: Før du tilslutter strøm til modulet, skal du konfigurere adgangen til programmet korrekt. Kontakterne forkert konfigureret kan resultere i modulfejl og/eller fejl på det tilsluttede udstyr og endda en brand.

1pgate
Fig. 7
Ethvert kontaktpunkt (f.eks. 3) bruges til at forbinde de enpolede gate-drevcontrollere. Eksemplet på tilslutning er vist i Fig. 7.


Tilslutning af dobbeltpolet portaktuator

Forsigtig: Før du tilslutter strøm til modulet, skal du konfigurere udgangene korrekt i applikationen. Kontakterne, der er konfigureret forkert, kan føre til samtidig strømforsyning til begge kanaler, hvilket resulterer i modulfejl og/eller fejl på det tilsluttede udstyr og endda brand.

2pgate
Fig. 8
To tilstødende kontaktpunkter (f.eks. 3, 4) skal bruges til at forbinde den dobbeltpolede gate-drevcontroller. Eksemplet på tilslutning er vist i Fig. 8.


Tilslutning af gardin/jalousi/jalousi-aktuator med 220V kraftstyring

Forsigtig: Før du tilslutter strøm til modulet, skal du konfigurere udgangene korrekt i applikationen. Kontakterne, der er konfigureret forkert, kan føre til samtidig strømforsyning til begge kanaler, hvilket resulterer i modulfejl og/eller fejl på det tilsluttede udstyr og endda brand.

Pjalousie
Fig. 9
To tilstødende kontaktpunkter (f.eks. 3, 4) skal bruges til at forbinde gardin-/jalousie-/rolladens-aktuatoren, under disse forhold er neutralledningen og jordledningen forbundet direkte til tavlen. Eksemplet på forbindelse er vist i Fig. 9.


Tilslutning af gardin/jalousi/jalousiaktuator med lavspændingsstyring

Forsigtig: Før du tilslutter strøm til modulet, skal du konfigurere udgangene korrekt i applikationen. Kontakterne, der er konfigureret forkert, kan føre til samtidig strømforsyning til begge kanaler, hvilket resulterer i modulfejl og/eller fejl på det tilsluttede udstyr og endda brand.

ljalousie
Fig. 10
To tilstødende kontaktpunkter (f.eks. 3, 4) skal bruges til at forbinde gardin-/jalousie-/rolladens aktuator med lavspændingsstyring. Eksemplet på tilslutning er vist i Fig. 10.

Tilslutning af følerelementer/kontakter/knapper

Tilslutning af bevægelsessensorer/lækagesensorer

Bevægelsessensorerne skal tilsluttes en hvilken som helst ledig indgang i1-i28; under disse forhold er deres strøm forbundet til kontaktpunkterne på +5V og GND for den relevante gruppe. Eksemplet på tilslutning er vist i Fig. 11.

IOC CONN LM.png
Fig. 11 tilslutning af bevægelsessensorer/lækagesensorer


Tilslutning af knapper/kontakter/magnetiske reedkontakter

Knapper og reed-kontakter er forbundet til enhver ledig indgang i1-i28, mens deres andet kontaktpunkt er forbundet til GND-punktet i den relevante METAFORSA-modulgruppe. Eksemplet på tilslutning er vist i Fig. 12-13.

Buttons MF3.png

Fig. 12 tilslutning af knapper/koblingsenheder
Reed-sv MF3.png

Fig. 13 tilslutning af magnetiske reed-afbrydere (vindues-/dørpositionssensorer)

Tilslutning af temperaturfølere

Temperaturfølere er forbundet til enhver fri indgang i1-i28, mens deres andet kontaktpunkt er forbundet til GND-punktet i den relevante METAFORSA-modulgruppe. Eksemplet på tilslutning er vist i Fig. 14.

IOC CONN T.png

Fig. 14 tilslutning af temperaturfølere

RGB-forbindelsesskema

ADVARSEL! Udgangskanaler bør kun tilsluttes ved hjælp af en forstærker, der bruger 5V PWM-signal fra IO-udgang som input

IOC RGB EX.png

Fig. 15 RGB forbindelse

WS2812B forbindelsesskema

IOC CONN WS.png

Fig. 16 WS2812B forbindelse

RS485 connection scheme

CAUTION! RS485 connection is only available for Metaforsa 3.plus and only occurs on 21 channel

MF3plus rs485.png

Fig. 17 RS485 connection

Connection of auxiliary equipment.

Expansion modules include Larnitech equipment connected through the CAN-bus. Such equipment includes: dimmers, RGB-backlit control modules, multimode sensors, etc. The equipment connected to the expansion port is defined automatically and does not require any preset tuning. Connector contact pin assignment is defined in Table 4. The example of connection is shown in Fig. 18.

CAN MF3.png
Caution! The 120 ohm terminating resistors should be installed at the end connectors between L and H contact points of CAN-bus. Ensure the connection is correct. The incorrect connection may cause sensor and/or module malfunction.

Module installation and connection procedure

ATTENTION! You must precisely follow the recommendations listed in the Security Requirements section hereof.
  1. Install the module in the switchboard on the DIN-rail and fix it with the special latch on the module base.
  2. Fasten the supply unit on the left side of the module.
  3. Connect the connector (4) having the noise filter pre-installed which is supplied complete with the module.
  4. Connect the connectors (5), (6).
  5. Connect the connectors (1), (2).
  6. Connect the connector (3).
  7. Apply power to the supply unit of METAFORSA module.
  8. Wait until the module is loaded, then configure it in accordance with the System Setup Instructions.
  9. Apply power to the connectors (1), (2).
  10. Check all equipment for proper operation.

METAFORSA module shut-off and deinstallation procedure

  1. De-energize the module by disconnecting the circuit breaker assembly of the load power supply and METAFORSA module supply unit. Verify the voltage is absent on the terminals (1), (2) of the connector wires and on the input terminals of the supply unit.
  2. Disconnect the load power supply connectors (1), (2).
  3. Disconnect the connector (3).
  4. Disconnect the connectors (4)-(6).
  5. Remove the module from the DIN-rail, releasing the latch at the bottom of the module base.

Hardware setup

To configure and control METAFORSA SMART HOUSE, you must install Larnitech software on your smartphone or tablet, which is available in App Store and Play Market. After installation, follow the System Setup Instructions.

Fault diagnostics and handling

The following are some possible faults and ways of fault handling. If you have any difficulty, or face the fault undeclared here, please contact the Technical Support: [1] or [support@larnitech.com]. There are also some tips in the FAQ section at our website [2].

The actuators do not operate:

  • ensure the outputs are properly configured in the application (see System Setup Instructions);
  • check the connection is correct in accordance with table 2 and paragraph 3.6;
  • ensure the power is supplied to the input power contact , i.e. all circuit breaker assembly are ON.
  • verify the operability of the connected equipment.

The module is off, indication absent:

  • check the connection to 24V supply unit as shown in table 2 (contacts pin assignment);
  • check the connection of the supply unit to 220V power mains, the indicator should be ON.

Network connection fault:

  • ensure the Ethernet cable is properly wired and connected to the connector;
  • ensure the LED status indicators are ON on the Ethernet connector;
  • check the LAN configuration is correct, Ethernet cable loops are absent;
  • METAFORSA module and the device you are connecting from are in the same network.

hold integer 0-10000 1-10 by default hold is the same as runtime hold is the bridging time in miliseconds, is used for gate and jalousie, lock; Example: hold=3500


The sensors do not operate:

  • ensure the inputs are properly configured in the application (System Setup Instructions);
  • check the connection is correct in accordance with table 2 and paragraph 3.7;
  • ensure the METAFORSA module is ON: circuit breaker assembly is closed, indication on the supply unit is ON, the module indication corresponds to the operating status – table 3;
  • check the power supply availability on the sensors;
  • check the integrity of lines laid to the sensors.

The auxiliary equipment does not operate:

  • check the connection is correct in accordance with table 2 and paragraph 3.8-9;
  • ensure the METAFORSA module is ON: circuit breaker assembly is closed, indication on the supply unit is ON, the module indication corresponds to the operating status – table 3;
  • check the integrity of the CAN lines, voltage supply on the modules.

HW Settings

Name Type, range SUBID Default Description
runtime integer 0-100 1-10 15 runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole);


Example: runtime=15

runtimeopen integer 0-60000 Blinds subId Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000
runtimeclose integer 0-60000 Blinds subId Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000
hold integer 0-10000 1-10 500 hold is the bridging time in milliseconds, is used for gate and jalousie (by default hold is the same as runtime for jalousie and gate), lock; Example: hold=3500
def string 'ON' 1-10 'OFF' def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON'
stop Char ‘R’ 1-7 (for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is ‘r’ or ‘R’ then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., ‘d’ ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop=’r’
out char[10] 98 'LLLLHHHHP-' Each char is responsible for the type of a particular channel
  • 'L'-Lamp;
  • 'M'-Lamp Inverse;
  • 'J'-Heating NO, valve-heating, normally open;
  • 'H'-Heating NC, valve-heating, normally closed;
  • 'B'-Blinds (2 pole), jalousie/curtains;
  • 'C'-Blinds Inverse (2 pole), jalousie/curtains, invert open-close;
  • 'G'-Gate (2 pole), 2 pole gate;
  • 'D'-Gate (2 pole) Inverse, 2 pole gate, invert open-close;
  • 'X'-Gate (1 pole /short press), 1 pole gate;
  • 'Z'-Gate (1 pole) Inverse, 1 pole gate, invert open-close;
  • 'V'-Valve (2 pole), 2 pole valve;
  • 'W'-Valve (2 pole) Inverse, 2 pole valve, invert open-close;
  • 'R'-Valve (1 pole), 1 pole valve,;
  • 'S'-Valve (1 pole) Inverse, 1 pole valve, invert open-close;
  • 'K'-Lock (short press);
  • 'N'-Lock (short press) Inverse;
  • 'P'-Blinds (2 pole);
  • 'O'-Blinds Inverse (2 pole), invert open-close;
  • 'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control;
  • 'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control;
  • 'Q'-FanCoil. Group3 (Lamp Toggle). For fancoil speed control;
  • 'U'-FanCoil. Group4 (Lamp Toggle). For fancoil speed control;
  • 'I'-FanCoil. Group5 (Lamp Toggle). For fancoil speed control;
  • '-'-none, nothing is connected.

Example: out='LLB-G-V-W-'

dm char[4] 98 ‘LLLL’ Each char is responsible for the type of a particular channel
  • ‘g’ – use like halogen dimer-lamp
  • ‘s’ – Soft Switch, lamp, when on/off power is supplied/deenergised smoothly (500msec)
  • ‘k’ – Switch, lamp, when on/off power is supplied/deenergised immediately
  • ‘l’ – LED Function, dimmable LED lamps
  • ‘v’ – linear Function of dimming
  • ‘-‘ – Channel disabled
  • ‘+’ – Regular channel

Example: dm=’skl-‘

def integer 0-250 11-14 100 The default brightness level in case of a power reset (1..250). Example: def=250
min integer 0-100 11-14 0 Minimum dimming level, example: min=10
max integer 0-100 11-14 100 Maximum dimming level, example max=95
start integer 0-100 11-14 0 The Start function is used for lamps that lack the minimal voltage to get turned on. If the set value is lower than the start value, the lamp is turned on at the start value and them the light is dimmed down to the set level. Example: start=60
force integer 0-100 11-14 10 Time duration of the starting value (measured in milliseconds). Example: force=20
runtime integer 0-60000 11-14 1000 Runtime is the speed of changing the brightness from ‘min’ to ‘max’ (measured in milliseconds). Example: runtime=1000
offset integer (+/- 0…39) 39-46 '0' sensor values offset; For example, offset is -3.8 :

Example: hw="offset='-3.8'"

io char[28] 98 io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' Each char is responsible for the type of a particular channel
  • '0' - led-dimmer
  • '1' - halogen-dimmer
  • '2' - linear-dimmer
  • '3'..'6' - RGB-3..6 channels
  • 'z' - WS2812B -string
  • 'e' - led-button inverse
  • 'd' - led-button
  • 'c' - button inverse
  • 'b' - button
  • 's' - switch
  • 'k' - contact inverse
  • 'h' - contact
  • 'l' - leak
  • 'n' - Neptun
  • 'v' - motion inverse
  • 'm' - motion
  • 'r' - thermo-resistor
  • 't' - DALLAS
  • '-' - none

Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'

hw string 98 - hw="...", where
  • pwm_invert – PWM inverting [1, 0];
  • lbn_bright – brightness of led buttons, range (0 - 255);
  • f – by default PWM frequency is 1000, range (1 - 5000).

Example:

1hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
Only for Metaforsa 3.plus
cfg string 98 9600/8N1 cfg='SPEED/BPS', where
  • SPEED – baud rate [1200..115200];
  • B – data length [7,8];
  • P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
  • S – stop bit length [1, 1.5 or 2].

Example:

1hw="cfg='9600/8N1'"
[Protocol] string 98 Protocol setting is described by protocol parameter. The following

protocols are supported:

  • 'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added;
  • 'dmx', DMX protocol;
  • 'CO2' for connecting Larnitech CO2 sensors;
  • 'salda' for connecting Salda ventilation.

Example:

1hw="cfg='9600/8N1' modbus"
echo on; off 98 'off' For settings check out and testing echo parameter can be used. Module

echo-reply can be turned on or off with the help of this parameter.Echo parameter value:

  • 'off'
  • 'on'

Example:

1hw="cfg='9600/8N1' echo='off'"
 1		<item addr="349:1" auto-period="600" cfgid="197" name="Lamp 1" type="lamp"/>
 2		<item addr="349:2" auto-period="600" cfgid="197" name="Lamp 2" type="lamp"/>
 3		<item addr="349:3" auto-period="600" cfgid="197" name="Lamp 3" type="lamp"/>
 4		<item addr="349:4" auto-period="600" cfgid="197" name="Lamp 4" type="lamp"/>
 5		<item addr="349:5" auto-period="600" cfgid="197" name="Lamp 5" type="lamp"/>
 6		<item addr="349:6" cfgid="197" name="Radiator" temperature-lag="0.2" type="valve-heating">
 7			<automation name="Eco" temperature-level="16"/>
 8			<automation name="Comfort" temperature-level="22"/>
 9			<automation name="Hot" temperature-level="25"/>
10		</item>
11		<item addr="349:7" cfgid="197" name="Radiator" temperature-lag="0.2" type="valve-heating">
12			<automation name="Eco" temperature-level="16"/>
13			<automation name="Comfort" temperature-level="22"/>
14			<automation name="Hot" temperature-level="25"/>
15		</item>
16		<item addr="349:8" cfgid="197" name="Radiator" temperature-lag="0.2" type="valve-heating">
17			<automation name="Eco" temperature-level="16"/>
18			<automation name="Comfort" temperature-level="22"/>
19			<automation name="Hot" temperature-level="25"/>
20		</item>
21		<item addr="349:9" cfgid="197" name="Jalousie" sub-type="120" type="jalousie"/>
22		<item addr="349:11" auto-period="600" cfgid="197" name="Dimmer 1" type="dimmer-lamp"/>
23		<item addr="349:12" auto-period="600" cfgid="197" name="Dimmer 2" type="dimmer-lamp"/>
24		<item addr="349:13" auto-period="600" cfgid="197" name="Dimmer 3" type="dimmer-lamp"/>
25		<item addr="349:14" auto-period="600" cfgid="197" name="Dimmer 4" type="dimmer-lamp"/>
26		<item addr="349:16" cfgid="197" name="Door 1" type="door-sensor"/>
27		<item addr="349:17" cfgid="197" name="Door 2" type="door-sensor"/>
28		<item addr="349:18" cfgid="197" name="Door 3" type="door-sensor"/>
29		<item addr="349:19" cfgid="197" name="Door 4" type="door-sensor"/>
30		<item addr="349:20" cfgid="197" name="Door 5" type="door-sensor"/>
31		<item addr="349:21" cfgid="197" name="Door 6" type="door-sensor"/>
32		<item addr="349:22" cfgid="197" name="Door 7" type="door-sensor"/>
33		<item addr="349:23" cfgid="197" name="Door 8" type="door-sensor"/>
34		<item addr="349:24" cfgid="197" name="Door 9" type="door-sensor"/>
35		<item addr="349:25" cfgid="197" name="Door 10" type="door-sensor"/>
36		<item addr="349:26" cfgid="197" name="Door 11" type="door-sensor"/>
37		<item addr="349:27" cfgid="197" name="Door 12" type="door-sensor"/>
38		<item addr="349:28" cfgid="197" name="Door 13" type="door-sensor"/>
39		<item addr="349:29" cfgid="197" name="Door 14" type="door-sensor"/>
40		<item addr="349:30" cfgid="197" name="Door 15" type="door-sensor"/>
41		<item addr="349:31" cfgid="197" name="Door 16" type="door-sensor"/>
42		<item addr="349:32" cfgid="197" name="Door 17" type="door-sensor"/>
43		<item addr="349:33" cfgid="197" name="Door 18" type="door-sensor"/>
44		<item addr="349:34" cfgid="197" name="Door 19" type="door-sensor"/>
45		<item addr="349:35" cfgid="197" name="Door 20" type="door-sensor"/>
46		<item addr="349:36" cfgid="197" name="Door 21" type="door-sensor"/>
47		<item addr="349:37" cfgid="197" name="Door 22" type="door-sensor"/>
48		<item addr="349:38" cfgid="197" name="Door 23" type="door-sensor"/>
49		<item addr="349:39" cfgid="197" name="Door 24" type="door-sensor"/>
50		<item addr="349:40" cfgid="197" name="Door 24" type="door-sensor"/>
51		<item addr="349:41" cfgid="197" name="Door 25" type="door-sensor"/>
52		<item addr="349:43" cfgid="197" name="IR receiver" type="ir-receiver"/>
53		<item addr="349:44" cfgid="197" name="RS485" type="com-port"/>
54		<item addr="349:90" cfgid="197" name="Current" system="yes" type="current-sensor"/>
55		<item addr="349:95" cfgid="197" name="Temperature" system="yes" type="temperature-sensor"/>
56		<item addr="349:96" cfgid="197" name="Temperature" system="yes" type="temperature-sensor"/>
57		<item addr="349:97" cfgid="197" name="Temperature" system="yes" type="temperature-sensor"/>
58		<item addr="349:98" cfgid="197" hw="out='LLLLLHHHB-' dm='LLLL' io='KKKKKKKKKKKKKKKKKKKKUKKKKKK-'" logic-ver="19" name="Temperature" sn="2533726919" system="yes" type="temperature-sensor"/>
59		<item addr="349:100" cfgid="197" name="RS232" type="com-port"/>